• Title/Summary/Keyword: THERMAL AGING

Search Result 620, Processing Time 0.031 seconds

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.

Thermal Lifetime Estimation of Coil Used for Dry-type Transformer (건식변압기 코일의 열적 수명평가)

  • Kim, M.K.;Huh, D.H.;Kim, I.S.;Jang, J.Y.;Moon, B.C.;Go, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.131-132
    • /
    • 2008
  • This paper describes a method to estimate the thermal lifetime of coil used in the dry-type molded transformer which is widely used in the domestic distribution system. In order to reduce the testing time, temperature accelerated aging test is planned. Finally, the thermal lifetime estimation method is composed of a temperature aging test and a cyclic test of temperature, humidly and lightning impulse voltage withstand test.

  • PDF

Thermal Analysis of Mica/Epoxy Composites used In Generator Stator Windings (발전기 고정자 권선에서 사용되는 마이카/에폭시의 열적 분석)

  • 김희동;김태완;김정훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.330-333
    • /
    • 1997
  • The thermal impact of mica/epoxy paper(130${\mu}{\textrm}{m}$) is investigated using XRD, DSC and TGL X-ray diffraction(XRD) analysis was performed to know the position and structure of mica crystal in insulation materials. A differential scanning calorimeter(DSC) was used to measure glass transition temperature and excess enthalphy of the composite materials that had been subjected to thermal aging. The glass transition temperature(T$_{g}$) measured by DSC is observed at 95.43$^{\circ}C$ and 113.43$^{\circ}C$, respectively. The T$_{g}$ also increases with increased aging time. Measurements performed by TGA(thermogravimetric analysis) have showed that weight loss profile of sound specimens are lower than those aged.ged.

  • PDF

Thermal Stability of 2.5Y-TZP under Low-Temperature Aging (2.5Y-TZP의 안정성에 관한 연구)

  • 장성도;오경영
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.2
    • /
    • pp.226-232
    • /
    • 1990
  • The degradation phenomena and thermal stability of 2.5Y-TZP at low-temperature were studied by means of XRD, Raman spectra and microstructural analysis. The degradation of heat-treated 2.5Y-TZP at 20$0^{\circ}C$-20hr in air was observed on the TZP surface, be caused by the cracks generated from tlongrightarrowm transformation, and the cracks was propagated inside the polycrystalline body. The ZrO2 grain boundaries and grains near the crack were revealed as if these were diffused and dissolved. And it was also observed mlongrightarrowt transformation as the degraded TZP was refired at 140$0^{\circ}C$, and it was thought to be the fact that the moisture in atmosphere during the aging process contributed to the degradation. The thermal stability of 2.5Y-TZP was improved dramatically with an addition of 3w/o CeO2 or a provision of high Y2O3 concentration on the TZP surface.

  • PDF

Effect of Thermal Cycle and Aging Heat Treatment on Transformation Characteristics of Cu-Zn-Al Shape Memory Alloys (Cu-Zn-Al계 형상기억합금의 변태특성에 미치는 열 Cycle 및 시효열처리의 영향)

  • Park, Pyeongyeol;Kim, Ickjun;Park, Seyun;Kim, Inbae;Park, Ikmin
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.2 no.4
    • /
    • pp.47-55
    • /
    • 1989
  • The effects of thermal cycle, aging heat treatment and Boron addition on the phase transformation characteristics and mechanical properties of the shape memory alloys of Cu-Zn-Al system, which was designed to operate about $80^{\circ}C$ by this research group, were studied. From the view point of the effects of thermal cycle on the phase transformation temperature change, it was found that up to 100 cycles Ms and Af points increased by $3-7^{\circ}C$ and Mf decreased a little bit and after that all of them were remain constant, and As point was not affected. All of the phase transformation temperatures were decreased $5-7^{\circ}C$ by aging heat treatment, at $140^{\circ}C$ for 24h however the effects of thermal cycle on aged alloys were same as on unaged alloys. As the thermal cycle increased the shape memory ability decreased a little up to 20 cycles, but above that it kept almost same ability. By Boron addition, grain size was refined from $1500{\mu}m$ to about $330{\mu}m$ and the hardness, fatigue property were improved but shape memory ability was lowered.

  • PDF

The Behavior Variation of the Ion Viscosity and the Compressive Strength of the Seawater and Freshwater Flooded Chlorosulfonated Polyethylene After Accelerated Thermally Ageing (가속 열화 후 해수 담수 침지된 Chlorosulfonated Polyethylene의 이온 점도와 압축 강도의 특성 변화)

  • Hong, So Young;Kim, Min Ju;Jeong, Eun Mi;Kim, Jin Pyo;Shin, Yong Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.490-495
    • /
    • 2019
  • This study performs the thermal aging of chlorosulfonated polyethylene (CSPE) for 807.36 and 1,614.48 hours at $110^{\circ}C$, which is equivalent to 40 and 80 years of aging at $50^{\circ}C$ in nuclear power plants, respectively. Flat-type CSPEs were soaked in seawater for five days and then dried for five days at room temperature. Furthermore, the soaked CSPEs were cleaned for 5 days with fresh water and dried for 1,100 days at room temperature. Through this process, the log IV of the CSPEs decreases, whereas the dissipation factor of the CSPEs increases as thermally accelerated aged years increase at the measured frequency. Although the phase degree of the response voltage versus excitation voltage of the CSPEs increases, that of the response current versus excitation voltage decreases with the thermally accelerated aging. The thermal conductivity of the CSPEs increases slightly, but the thermal diffusivity does not vary with the thermally accelerated aged year increase. The displacement of the compressive strength of the CSPEs decreases gradually as the thermally accelerated aged years increase.

Effects of Aging on Properties of MgO-Partially Stabilized Zirconia (마그네시아 부분안정화 지르코니아 소결체의 특성에 미치는 열처리 효과)

  • 정형진;오영제;이홍림
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.3
    • /
    • pp.243-250
    • /
    • 1987
  • The effects aging on some properties and thermal-shock behavior of zirconia partially stabilized with 9 mol% MgO (9MZ) were studied. 9MZ specimens were aged over $1200^{\circ}$-$1400^{\circ}C$ for 12hours subsequently, after sintering at $1650^{\circ}C$ for 4 hours. Fracture strength(both before and after thermal-shock test), linear thermal expansion, monoclinic fraction and phase transition by XRD, density, galvanic potential and microstructure were measured. Quantitative chemical analysis around the grain-boundary of the specimen aged at $1350^{\circ}C$ was also conducted by EDX. The aging of 9MZ specimen causes a thermal decomposition of cubic-$ZrO^{2}$ into the formation metastable tetragonal-$ZrO^{2}$ and MgO. The former increases the residual strength after thermal-shock test and the latter improves the thermal-shock resistance due to thermal conduction through the continuous magnesia phase and the formation of monoclinic phase content in matrix were increased with decreasing the aging temperature from $1400^{\circ}C$ to $1200^{\circ}C$. Galvanic potential of the aged specimen exhibited a proper emf characteristic.

  • PDF

Study on the Thermal Property and Aging Prediction for Pressable Plastic Bonded Explosives through ARC(Heat-wait-search method) & Isothermal Conditions (ARC(Heat-wait-search method)와 Isothermal 조건을 이용한 압축형 복합화약의 열적 특성 및 노화 예측 연구)

  • Lee, Sojung;Kim, Seunghee;Kwon, Kuktae;Jeon, Yeongjin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.55-60
    • /
    • 2018
  • The thermal property is one of the most important characteristics in the field of energetic materials. Because energy materials release decomposition heat, differential scanning calorimetry (DSC) is frequently used for thermal analysis. However, thermodynamic events, such as melting can interfere with DSC kinetic analysis. In this study, we use isothermal mode for DSC measurement to avoid thermodynamic issues. We also merge accelerating rate calorimetry(ARC) data with DSC data to obtain a robust prediction results for small scale samples and for large scale samples as well. For the thermal property prediction, advanced kinetics and technology solutions(AKTS) programs are used.

The information system concept for thermal monitoring of a spent nuclear fuel storage container

  • Svitlana Alyokhina
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3898-3906
    • /
    • 2023
  • The paper notes that the most common way of handling spent nuclear fuel (SNF) of power reactors is its temporary long-term dry storage. At the same time, the operation of the dry spent fuel storage facilities almost never use the modern capabilities of information systems in safety control and collecting information for the next studies under implementation of aging management programs. The author proposes a structure of an information system that can be implemented in a dry spent fuel storage facility with ventilated storage containers. To control the thermal component of spent fuel storage safety, a database structure has been developed, which contains 5 tables. An algorithm for monitoring the thermal state of spent fuel was created for the proposed information system, which is based on the comparison of measured and forecast values of the safety criterion, in which the level of heating the ventilation air temperature was chosen. Predictive values of the safety criterion are obtained on the basis of previously published studies. The proposed algorithm is an implementation of the information function of the system. The proposed information system can be used for effective thermal monitoring and collecting information for the next studies under the implementation of aging management programs for spent fuel storage equipment, permanent control of spent fuel storage safety, staff training, etc.

Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers (전력용 변압기의 열화에 의해 생성된 부산물의 분석)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.