• 제목/요약/키워드: TFM

검색결과 68건 처리시간 0.025초

제어봉 구동장치용 횡자속형 전동기의 제어기 개발 (Development of the Controller for TFM with Contol-Rod)

  • 김종무;정연호;강도현;임태윤;김동희;이석규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2001
  • In the System-integrated modular advanced reactor(SMART), the motor for Control element drive mechanism(CEDM) requires high density power and simple drive mechanism to reduce volume because of restriction by install-space and must satisfy the reactor operating circumstances with high pressure and temperature. To Maximize the characteristics of the TFM, we chose the asymmetric bridge converter as the driving system for TFM. Because two switching devices are connected in series with the stator winding of each phases in the asymmetric bridge converter all the phases are not affected by another phase but controlled independently. Also, this converter has many advantages that the various control methods can be adopted, it is easy to control, and that in case that the switching devices of a phase are damaged, the affects can be minimized.

  • PDF

열응답계수를 이용한 TFM 부하계산법의 제안 (Development of a TFM load calculation program based on thermal response factor)

  • 최우영;고철균;이재헌;류해성
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.684-691
    • /
    • 1999
  • A load calculation program based on TFM(Transfer function method) has been proposed in this study. The validity of the current method has been verified by comparing heat gain calculation by TRF(Thermal response factor) with that by CTF(Conduction transfer function) adopted in ASHRAE. In addition, it seems that the CTF coefficients given in ASHRAE tables have somewhat ambiguity The load calculation program developed in the current study has been employed to calculate cooling load from the exterior walls and roof of example 6 in the ASHRAE. The results are found in good agreement.

  • PDF

팜유와 아보카도유로부터 효소적 interesterification을 통한 trans free margarine stock 제조 및 이화학적 특성 연구 (Development and Characterization of Trans Free Margarine Stock from Lipase-Catalyzed Interesterification of Avocado and Palm Oils)

  • 이윤정;이기택
    • 한국식품과학회지
    • /
    • 제41권3호
    • /
    • pp.231-237
    • /
    • 2009
  • 팜유와 아보카도유를 이용하여 효소적 방법을 통해 trans free margarine stock(TFMS)을 제조하였다. 회분식 반응기(stirred batch type reactor)를 통한 본 반응은 sn-1,3 위치 특이성을 가진 lipozyme RM IM(from Rhizomucor miehei)을 사용하였다. 반응기질 대두극도경화유와 아보카도유 및 팜유는 30:150:120(g)의 비율로 230 rpm, $65^{\circ}C$에서 합성하였으며 이를 통해 이화학적 특성을 분석하였다. 재구성 지질의 DSC 분석 결과 TFMS의 solid fat content(SFC)는 $5^{\circ}C$에서 58.6%, $35^{\circ}C$에서의 약 8.5%로 확인 되었으며 7.3, 23.6, $35.3^{\circ}C$의 DSC 상의 melting point 특성을 나타내었다. TFMS는 C16:0(약 29%)과 C18:1(약 45%)이 주요 지방산으로 확인되었고 ${\Sigma}SFA$는 40.7%이었으며 trans 지방산은 검출되지 않았다. Sn-2 위치에는 주요적으로 C16:0(21.6%)과 C18:1(50.2%)의 지방산 조성이 확인되었다. RP-HPLC를 통해 TFMS를 이루고 있는 TAG의 PN을 확인 하였다. 주요적으로 PN=48이 대부분을 차지하였고 PN=46, PN=50으로 분리되었으며 TFMS의 반응 전과 비교 시 차별적인 TAG peak를 확인할 수 있었다. 한편, ${\alpha}-$, ${\gamma}-$${\delta}$-tocopherol이 각각 5.7, 2.1, 1.7 mg/100 g을 나타냈으며 산가, 요오드가, 비누화가를 통해 TFMS의 이화학적 특성을 확인 할 수 있었다. TFMS를 통해 마가린 제조 시 물성 변화를 고려하여 마가린의 적합한 물성을 지닐 수 있을 것이라 사료된다.

횡자속형 전동기의 운전특성에 관한 연구 (A Study on Control Characteristics of Transeverse Flux Motor)

  • 김종무;정연호;강도현;임태윤;이석규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1197-1199
    • /
    • 2001
  • TFM(Transeverse Flux Motor) is switched reluctance motor with new structure of novel design concept based on the high efficiency and power density compare to induction motor used on wide industrial field. This paper realized FWM asymmetric converter drive control system for TFM using IGBT and DSP.

  • PDF

전이함수모형을 이용한 약품비 지출의 예측 (Forecasting drug expenditure with transfer function model)

  • 박미혜;임민성;성병찬
    • 응용통계연구
    • /
    • 제31권2호
    • /
    • pp.303-313
    • /
    • 2018
  • 본 논문에서는 약품비 지출에 대한 예측을 수행하기 위하여 시계열 모형을 도입한다. 2012년 약가 일괄인하를 반영하기 위하여 구간별 모형을 토대로, 자기회귀오차모형과 전이함수모형을 고려하였다. 자기회귀오차모형에서는 예측의 편리성을 위하여 결정적 추세만을 고려하였으며, 전이함수모형에서는 주요한 외생변수와의 교차상관성을 이용하여 약품비 지출의 인과 메커니즘을 설명하였다. 각 모형에서 약가 일괄인하 이후 수준 변화가 유의하게 나타났으며, 전이함수모형에서는 의약품 사용자 수 및 노인환자 비중 시계열 변수가 유의하게 나타났다. 자기회귀오차모형은 약가 일괄인하로 의한 약품비 수준이동에 좌우되어 비교적 낮은 예측값이 도출되었으며, 전이함수모형은 약품비 지출에 영향을 미치는 외부 설명변수의 증가 추세가 적절히 반영되어 더 높은 예측값을 보였다. 설명변수를 포함하지 않을 경우, 약품비 수준이동만을 고려한 ARIMA 모형은 약품비 지출 추세를 가장 높이 예측하였다.

Association between serum alanine amino­transferase level and obesity indices in Korean adolescents

  • Ahn, Moon Bae;Bae, Woo Ri;Han, Kyung Do;Cho, Won Kyoung;Cho, Kyoung Soon;Park, So Hyun;Jung, Min Ho;Suh, Byung Kyu
    • Clinical and Experimental Pediatrics
    • /
    • 제58권5호
    • /
    • pp.165-171
    • /
    • 2015
  • Purpose: To analyze the correlation between serum alanine aminotransferase (ALT) and obesity indices including body mass index (BMI), body fat percentage (BFP), total fat mass (FM), truncal fat mass (TFM), waist circumference (WC), and waist-to-height ratio (WHtR) in Korean adolescents. Methods: This was a cross-sectional study based on data derived from the 2010-2011 Korean National Health and Nutrition Examination Surveys (KNHANES). Subjects were Korean adolescents aged 10-18 years (871 total; 475 boys and 396 girls) who participated in KNHANES. Results: In both sexes, BMI, FM, TFM, WC, and WHtR were higher when ALT levels were in the 4th quartile. In boys, there was a significant positive correlation between ALT level and BMI, BFP, FM, TFM, WC, and WHtR (r=0.55, P<0.0001 for BMI; r=0.52, P<0.0001 for BFP; r=0.58, P<0.0001 for FM; r=0.61, P<0.0001 for TFM; and r=0.56, P<0.0001 for WC; r=0.62, P<0.0001 for WHtR), and the correlation coefficient was higher than that in girls. Conclusion: Our results suggest a significant positive association between serum ALT level and obesity indices in male adolescents.

태국 Tak 플럭스 관측소의 실시간 자료 감시 및 모사 시스템 (Real Time Monitoring and Simulation System (RTMASS) for Tak Flux Measurement Site, Thailand)

  • Wonsik Kim;Hyungjun Kim;Joon Kim;Yasushi Agata;Shin Miyazaki;Taikan Oki
    • 한국농림기상학회지
    • /
    • 제5권2호
    • /
    • pp.116-127
    • /
    • 2003
  • 태국 북서부의 Tak 지방에 KoFlux(Korean Flux Network) 연구의 일환으로서 플럭스 관측소(Tak flux measurement, TFM site)가 설립되었다. 이곳에서 이산화탄소와 물, 그리고 에너지 플럭스를 관측하기 위해 와 공분산시스템(eddy covariance system)을 적용하였으며 관측된 자료는 실시간 자료 감시 및 모사 시스템(Real time monitoring and simulation system, RTMASS)을 이용하여 처리되어 전송된다. RTMASS는 KoFlux-DIS(Data information system)의 핵심 구조이고 원격지 시스템과 중앙 시스템으로 나누어지며 자료의 수집 및 전송. 자료의 저장 및 처리가 본 시스템의 주된 기능이다. 난류특성과 미기상학적인 분석 자료에 따르면, TM 관측소는 열대 낙엽수림에 대한 다양한 플럭스 및 에너지 수지를 관측하고 분석하는데 적합하다고 할 수 있다.

조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향 (Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry)

  • 김성수;이선도;이남주;신용철;모은희;이춘호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.7-11
    • /
    • 2012
  • PET/CT에 사용되는 방사성의약품 FDG와 CT 조영제가 DXA를 이용하여 측정하는 BMC, BMD, TFM, LBM 등의 결과에 미치는 영향을 알아보고자 하였다. 2011년 12월부터 2012년 3월까지 본원 PET/CT를 시행한 환자 중 본 연구에 참여를 동의한 환자 총 22명을 대상으로 하였다. 실험은 두 집단으로 나누어 실험을 진행하였는데 첫 번째 집단은 17명으로 PET/CT 용 방사성의약품인 FDG 정맥 주사 전에 WB DXA를 시행한 다음 FDG 정맥주사 1시간 후 CT 조영제 사용 없이 PET/CT (Non-Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA를 진행하였다. 두 번째 집단은 총 5명으로 첫 번째 집단과 마찬가지로 FDG 정맥 주사 전 WB DXA를 시행한 다음 FDG 정맥 주사 1시간 후 CT 조영제 사용하여 PET/CT (Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA 진행하였다. 결과는 PET/CT 전 후 DXA에서 WB-BMC, WB-BMD, TFM 그리고 LBM 등을 측정하였고 각 항목의 변화율을 산출하여 비교하였다. Non-Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 골밀도 및 체성분의 변화율은 WB-BMC, +2.4%; WB-BMD, +1.8%; TFM, -6.8%; LBM, +2.2%였고 각 항목의 변화는 통계적으로 유의한 차이가 없었다. Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 변화율은 WB-BMC, +13.7%; WB-BMD, +9.3%; TFM, -34.1%; LBM, +13.6%였고 Contrast Enhancement $^{18}F$-FDG PET/CT 전과 후의 골밀도 및 체성분 측정치의 변화는 통계적으로 유의하였다. 본 연구에서 Non-Contrast Enhancement $^{18}F$ PET/CT 후에는 DXA 시행은 결과에 영향이 없어 가능할 것이라 생각되어지나 Contrast Enhancement $^{18}F$-FDG PET/CT검사 후에 시행한 DXA 검사의 결과는 신뢰도가 감소될 것으로 사료된다.

  • PDF

전달함수을 이용한 유정압테이블 운동정밀도 해석법의 제안 및 이론적 검증 (Proposal and Theoretical Verification on Motion Error Analysis Method of Hydrostatic Tables Using Transfer Function)

  • 박천홍;오윤진;이찬홍;홍준희
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.56-63
    • /
    • 2002
  • A new model utilizing a transfer function is introduced in the present paper for analizing motion errors of hydrostatic tables. Relationship between film reaction force in a single hydrostatic pad and form error of a guide rail is derived at various spacial frequencies by finite element analysis, and it is expressed as a transfer function. This transfer function clarifies so called averaging effect of the oil film quantitively. For example, it is found that the amplitide of the film reaction farce is reduced as the spacial frequency increases or relative width of the pocket is reduced. Motion errors of a multiple pad table is estimated from transfer function, geomatric relationship between each pads and form errors of a guide rail, which is named as Transfer Function Method(TFM). Calculated motion errors by TFM show good agreement with motion errors calculated by Multi Pad Method, which is considered entire table as an analysis object. From the results, it is confirmed that the proposed TFM is very effective to analyze the motion errors of hydrostatic tables.

Theoretical Verification on the Motion Error Analysis Method of Hydrostatic Bearing Tables Using a Transfer Function

  • Park, Chun-Hong;Oh, Yoon-Jin;Lee, Chan-Hong;Hong, Joon-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권2호
    • /
    • pp.64-70
    • /
    • 2003
  • A new method using a transfer function is introduced in the present paper for analyzing the motion errors of hydrostatic bearing tables. The relationship between film reaction force in a single-side hydrostatic pad and the form error of guide rail is derived at various spatial frequencies by finite element analysis, and it is expressed as a transfer function. This transfer function clarifies so called 'the averaging effect of an oil film' quantitively. It is found that the amplitude of film force is reduced as the spatial frequency increases or the relative width of the pocket is reduced. The motion errors of a multi pad type table are estimated using a transfer function, the form errors of a guide rail and the geometric relationship between the pads. The method is named as the Transfer Function Method (TFM). The motion errors calculated by the TFM show good agreement with the motion errors calculated by the Multi Pad Method considering the entire table as an analysis object. From the results, it is confirmed that the proposed TFM is very effective to analyze the motion errors of hydrostatic tables.