• Title/Summary/Keyword: TEX>

Search Result 313,332, Processing Time 0.461 seconds

Development of Selective Heribicide for Control of Weeds in Turf (잔디밭 잡초방제(雜草防除)를 위한 선택성(選擇性) 제초제(除草劑)의 개발(開發)에 관한 연구(硏究))

  • Han, Seong-Soo
    • Korean Journal of Weed Science
    • /
    • v.7 no.2
    • /
    • pp.186-199
    • /
    • 1987
  • This study was carried out to investigate the growth of Korean lawn grass (Zoysia japonica Steud.), penncross bentgrass (Agrostis palustris Huda) and seaside bentgrass (Agrostis spp.) under application of 21 pre- and post-emergence herbicides and the weeding effect of 14 annual and 4 perennial weeds with them for the purpose of the systematic chemical weed control in turf. The results obtained were as follows; 1. Napropamide, napropamide + triclopyr and benefin were safe for Korean lawn grass and two kinds of bentgrasses when they were treated at 4 and 25 days after transplanting of turfgrasses. Simazine, lenacil and bentazon inhibited the growth of bentgrasses, but not Korean lawn grass. 2. The preemergence application of simazine, benefin and napropamide + simazine showed excellent control for Digitaria sanguinalis, Cyperus amuricus, Chenopodium album, Portulaca oleracea and Centipeda minima. Lenacil was excellent for control of all the tested weeds except Chenopodium album, napropamide excellent for them except Cyperus amuricus and Portulaca oleraces, and bentazon good for them except Digitaria sanguinalis. When simazine was treated with either napropamide or triclopyr at preemergence of weeds, weeding effect increased without inhibition of lawn growth. 3. The postemergence application of mecoprop, bentazon, benefin + dicamba and benefin + mecoprop was safe to bentgrasses. All the tested postemergence herbicides except simazine + atrazine did not inhibit the growth of Korean lawn grass. 4. Other postemergence herbicides mecoprop and triclopyr were excellent for the control of Echinochloa crusgalli and those except benefin and mecoprop excellent for Kummerovia striata. Digitaria sanguinalis was controlled by treating with all the tested post emergence herbicides and Cyperus amuricus controlled only by bentazon. 5. The growth rates of bentgrasses treated with simazine, lenacil and napropamide + simazine were lower than that of hand-weeded check, and those of benefin, bentazon, napropamide, napropamide + triclopyr, stomp, bensulide and triclopyr were higher than that one when applied at spring season. Korean lawn grass growth appeared to be good under application of all the tested preemergence herbicides at spring. Lanacil and bentazone showed poor control of Echinochloa crusgalli, and bensulide showed poor control of Erigeron canadensis. Also, napropamide and bentazon were not good for Kummerovia striata control. However, at the respective rates of all the tested herbicides, these three weeds were greatly controlled by 85-100% of weeding effect. 6. At the application of autumn season, bentazon, napropamide, pendimethalin, benefin, napropamide + triclopyr, bensulide and triclopyr seemed to be safe against three kinds of turfgrasses. But simazine, napropamide + simazine inhibited the growth of bentgrasses except Korean lawn grass. In terms of weed control performance, triclopyr was poor for controlling Echinochloa crusgalli and bentazon and stomp for Poa annua, napropamide, benefin and bensulide for Stellaria medico. Stellaria uliginosa and Cerastium caespitosum were well controlled by all the tested preemergence herbicides. 7. Korean lawn grass was safe when paraquat and glyphosate were treated at the dormanant season of turfgrass. These herbicides showed excellent controll of Poa annua but poor control of perennials in order of Trifolium repens < Miscanthus sinensis < Calystegia japonica < Artemisia asiatica. 8. In field test, all of 19 herbicides seemed to be safe when treated at Korean lawn grass. All of 10 preemergence herbicides were excellent for controlling annual weeds, but poor for perennial ones. All of 9 postemergence herbicides showed a excellent control for broad-leaf weeds.

  • PDF

Effects of High Glucose and Advanced Glycosylation Endproducts(AGE) on the in vitro Permeability Model (당과 후기당화합물의 생체 외 사구체여과율 모델에 대한 역할)

  • Lee Jun-Ho;Ha Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2006
  • Purpose : We describe the changes of rat glomerular epithelial cells when exposed to high levels of glucose and advanced glycosylation endproducts(AGE) in the in vitro diabetic condition. We expect morphological alteration of glomerular epithelial cells and permeability changes experimentally and we may correlate the results with a mechanism of proteinuria in DM. Methods : We made 0.2 M glucose-6-phsphate solution mixed with PBS(pH 7.4) containing 50 mg/mL BSA and pretense inhibitor for preparation of AGE. As control, we used BSA. We manufactured and symbolized five culture dishes as follows; B5 - normal glucose(5 mM) + BSA, B30 - high glucose(30 mM) + BSA, A5 - normal glucose(5 mM) + AGE, A30 - high glucose(30 mM) + AGE, A/B 25 - normal glucose(5 mM) + 25 mM of mannitol(osmotic control). After the incubation period of both two days and seven days, we measured the amount of heparan sulfate proteoglycan(HSPG) in each dish by ELISA and compared them with the B5 dish at 2nd and 7th incubation days. We observed the morphological changes of epithelial cells in each culture dish using scanning electron microscopy(SEM). We tried the permeability assay of glomerular epithelial cells using cellulose semi-permeable membrane measuring the amount of filtered BSA through the apical chamber for 2 hours by sandwich ELISA. Results : On the 2nd incubation day, there was no significant difference in the amount of HSPG between the 5 culture dishes. But on the 7th incubation day, the amount of HSPG increased by 10% compared with the B5 dish on the 2nd day except the A30 dish(P<0.05). Compared with the B5 dish on the 7th day the amount of HSPG in A30 and B30 dish decreased to 77.8% and 95.3% of baseline, respectively(P>0.05). In the osmotic control group (A/B 25) no significant correlation was observed. On the SEM, we could see the separated intercellular junction and fused microvilli of glomerular epithelial cells in the culture dishes where AGE was added. The permeability of BSA increased by 19% only in the A30 dish on the 7th day compared with B5 dish on the 7th day in the permeability assay(P<0.05). Conclusion: We observed not only the role of a high level of glucose and AGE in decreasing the production of HSPG of glomerular epithelial cells in vitro, but also their additive effect. However, the role of AGE is greater than that of glucose. These results seems to correlate with the defects in charge selective barrier. Morphological changes of the disruption of intercellular junction and fused microvilli of glomerular epithelial cells seem to correlate with the defects in size-selective barrier. Therefore, we can explain the increased permeability of glomerular epithelial units in the in vitro diabetic condition.

  • PDF

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

An Examination into the Illegal Trade of Cultural Properties (문화재(文化財)의 국제적 불법 거래(不法 去來)에 관한 고찰)

  • Cho, Boo-Keun
    • Korean Journal of Heritage: History & Science
    • /
    • v.37
    • /
    • pp.371-405
    • /
    • 2004
  • International circulation of cultural assets involves numerous countries thereby making an approach based on international law essential to resolving this problem. Since the end of the $2^{nd}$ World War, as the value of cultural assets evolved from material value to moral and ethical values, with emphasis on establishing national identities, newly independent nations and former colonial states took issue with ownership of cultural assets which led to the need for international cooperation and statutory provisions for the return of cultural assets. UNESCO's 1954 "Convention for the Protection of Cultural Property in the Event of Armed Conflict" as preparatory measures for the protection of cultural assets, the 1970 "Convention on the Means of Prohibiting and Preventing the Illicit Import and Transfer of Ownership of Cultural Property" to regulate transfer of cultural assets, and the 1995 "Unidroit Convention on Stolen or Illegally Exported Cultural Objects" which required the return of illegally acquired cultural property are examples of international agreements established on illegal transfers of cultural assets. In addition, the UN agency UNESCO established the Division of Cultural Heritage to oversee cultural assets related matters, and the UN since its 1973 resolution 3187, has continued to demonstrate interest in protection of cultural assets. The resolution 3187 affirms the return of cultural assets to the country of origin, advises on preventing illegal transfers of works of art and cultural assets, advises cataloguing cultural assets within the respective countries and, conclusively, recommends becoming a member of UNESCO, composing a forum for international cooperation. Differences in defining cultural assets pose a limitation on international agreements. While the 1954 Convention states that cultural assets are not limited to movable property and includes immovable property, the 1970 Convention's objective of 'Prohibiting and preventing the illicit import, export and transfer of ownership of cultural property' effectively limits the subject to tangible movable cultural property. The 1995 Convention also has tangible movable cultural property as its subject. On this point, the two conventions demonstrate distinction from the 1954 Convention and the 1972 Convention that focuses on immovable cultural property and natural property. The disparity in defining cultural property is due to the object and purpose of the convention and does not reflect an inherent divergence. In the case of Korea, beginning with the 1866 French invasion, 36 years of Japanese colonial rule, military rule and period of economic development caused outflow of numerous cultural assets to foreign countries. Of course, it is neither possible nor necessary to have all of these cultural properties returned, but among those that have significant value in establishing cultural and historical identity or those that have been taken symbolically as a demonstration of occupational rule can cause issues in their return. In these cases, the 1954 Convention and the ratification of the first legislation must be actively considered. In the return of cultural property, if the illicit acquisition is the core issue, it is a simple matter of following the international accords, while if it rises to the level of diplomatic discussions, it will become a political issue. In that case, the country requesting the return must convince the counterpart country. Realizing a response to the earnest need for preventing illicit trading of cultural assets will require extensive national and civic societal efforts in the East Asian area to overcome its current deficiencies. The most effective way to prevent illicit trading of cultural property is rapid circulation of information between Interpol member countries, which will require development of an internet based communication system as well as more effective deployment of legislation to prevent trading of illicitly acquired cultural property, subscription to international conventions and cataloguing collections.

How to improve the accuracy of recommendation systems: Combining ratings and review texts sentiment scores (평점과 리뷰 텍스트 감성분석을 결합한 추천시스템 향상 방안 연구)

  • Hyun, Jiyeon;Ryu, Sangyi;Lee, Sang-Yong Tom
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.219-239
    • /
    • 2019
  • As the importance of providing customized services to individuals becomes important, researches on personalized recommendation systems are constantly being carried out. Collaborative filtering is one of the most popular systems in academia and industry. However, there exists limitation in a sense that recommendations were mostly based on quantitative information such as users' ratings, which made the accuracy be lowered. To solve these problems, many studies have been actively attempted to improve the performance of the recommendation system by using other information besides the quantitative information. Good examples are the usages of the sentiment analysis on customer review text data. Nevertheless, the existing research has not directly combined the results of the sentiment analysis and quantitative rating scores in the recommendation system. Therefore, this study aims to reflect the sentiments shown in the reviews into the rating scores. In other words, we propose a new algorithm that can directly convert the user 's own review into the empirically quantitative information and reflect it directly to the recommendation system. To do this, we needed to quantify users' reviews, which were originally qualitative information. In this study, sentiment score was calculated through sentiment analysis technique of text mining. The data was targeted for movie review. Based on the data, a domain specific sentiment dictionary is constructed for the movie reviews. Regression analysis was used as a method to construct sentiment dictionary. Each positive / negative dictionary was constructed using Lasso regression, Ridge regression, and ElasticNet methods. Based on this constructed sentiment dictionary, the accuracy was verified through confusion matrix. The accuracy of the Lasso based dictionary was 70%, the accuracy of the Ridge based dictionary was 79%, and that of the ElasticNet (${\alpha}=0.3$) was 83%. Therefore, in this study, the sentiment score of the review is calculated based on the dictionary of the ElasticNet method. It was combined with a rating to create a new rating. In this paper, we show that the collaborative filtering that reflects sentiment scores of user review is superior to the traditional method that only considers the existing rating. In order to show that the proposed algorithm is based on memory-based user collaboration filtering, item-based collaborative filtering and model based matrix factorization SVD, and SVD ++. Based on the above algorithm, the mean absolute error (MAE) and the root mean square error (RMSE) are calculated to evaluate the recommendation system with a score that combines sentiment scores with a system that only considers scores. When the evaluation index was MAE, it was improved by 0.059 for UBCF, 0.0862 for IBCF, 0.1012 for SVD and 0.188 for SVD ++. When the evaluation index is RMSE, UBCF is 0.0431, IBCF is 0.0882, SVD is 0.1103, and SVD ++ is 0.1756. As a result, it can be seen that the prediction performance of the evaluation point reflecting the sentiment score proposed in this paper is superior to that of the conventional evaluation method. In other words, in this paper, it is confirmed that the collaborative filtering that reflects the sentiment score of the user review shows superior accuracy as compared with the conventional type of collaborative filtering that only considers the quantitative score. We then attempted paired t-test validation to ensure that the proposed model was a better approach and concluded that the proposed model is better. In this study, to overcome limitations of previous researches that judge user's sentiment only by quantitative rating score, the review was numerically calculated and a user's opinion was more refined and considered into the recommendation system to improve the accuracy. The findings of this study have managerial implications to recommendation system developers who need to consider both quantitative information and qualitative information it is expect. The way of constructing the combined system in this paper might be directly used by the developers.

The relationship of nutrition of rice and positive evaluation of the rice-based meal on the physical and emotional self-diagnosis and learning efficiency of the middle and highschool students in the jeonju area (전주 지역 청소년 대상 쌀의 영양과 쌀을 기반으로 한 식사에 대한 긍정적 평가에 따른 신체·정서적 자각증상 및 학습 효능감과의 관련성)

  • Lee, Hyeon Kyeong;Lee, Young Seung;Jung, Soo Jin;Kang, Min Sook;Hwang, Yu Jin;Yoo, Sun Mi;Cha, Yeon Soo;Cho, Soo Muk
    • Journal of Nutrition and Health
    • /
    • v.52 no.1
    • /
    • pp.90-103
    • /
    • 2019
  • Purpose: This study examined the relationship of the nutrition of rice and the positive evaluation of the rice-based meal with the food consumption habits, physical and emotional health status, and learning efficacy of 601 middle and high school students in Jeonju area. Methods: The participants were divided into two groups using cluster analysis in that the participants belonging to the upper groups had a center score of 46.86 (n = 348), while the people belonging to the lower group had a center score of 36.89 (n = 253). Statistical differences were tested for all the relationships between the physical and emotional health symptoms and learning efficacy between the groups at the ${\alpha}=0.05$ level. Results: Significant differences in the physical self-evaluated symptoms were observed in all five items in each cluster (p < 0.05). In the case of the emotional health status, nine out of 10 items showed significant differences between the groups. Similarly, significant differences in all five items in learning efficacy questionnaire were noted (p < 0.05). Positive attitudes of the parents toward having breakfast also showed significant differences among the groups. Conclusion: The nutrition of rice and a positive evaluation of the rice-based meals significantly affect the physical and emotional health status and learning efficacy of juveniles. These findings can be used as baseline information for promoting nutrition education, particularly rice-based breakfast.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.