• Title/Summary/Keyword: TD3

Search Result 374, Processing Time 0.029 seconds

A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector (열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가)

  • 박정근;유기호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

Fabrication of the Ce$O_{2}$ thin film by MOCVD process (MOCVD 공정을 이용한 CeO2 박막 제조)

  • 김호진;주진호;전병혁;정충환;박해웅;김찬중
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.133-136
    • /
    • 2003
  • The CeO$_2$ thin films were deposited on the biaxially textured Ni substrates by MOCVD process. The (200) oriented CeO$_2$ films were formed at the deposition temperature(Td) of 500~52$0^{\circ}C$, the oxygen partial pressure(PO2) of 0.90~3.33 torr and the deposition time(t) of 3~25 min. The surface roughness and gain size rapidly increased at Td $\geq$ 52$0^{\circ}C$ due to the grain growth. The surface roughness also increased as the deposition time increased. The optimized deposition conditions of the CeO$_2$ films for the YBCO coated conductor were Td= 500~51$0^{\circ}C$, PO2= 2.30 torr and t= 10~12 min.

  • PDF

Dynamic Channel Allocation Algorithm for TD-SCDMA Smart Antenna System with Inter-cell Interference (인접 셀 간섭영향을 고려한 TD-SCDMA 스마트 안테나 시스템의 동적 채널 할당 알고리즘)

  • Jang, Min-Seok;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.4
    • /
    • pp.415-422
    • /
    • 2007
  • In this paper, we proposed a new dynamic channel allocation algorithm for TD-SCDMA with cross time slots. In order to reduce the interference in cross time slot, the mobile stations (MSs) are divided into two groups: the Near Group consisting of MSs near by the base station(BS) and the Far Group including the MSs far from the BS. The reverse link for MSs in the Near Group and forward link for MSs in the Far Group are allocated to the cross time slot. In cellular systems, a BS has multiple neighbor BSs. Some of neighbor BSs can operate in the same direction link while the others have cross time slot. Thus, it is required to determine which BS has the most significant impact in terms of interference. We divide each cell into 6 areas based on the direction of arrival of smart antenna and the most significant neighbor sector is determined with this division. The proposed allocation method and area division method can avoid the severe interference in cross time slots and increase the system capacity about 2%~9% compared to FCA, and 0.5%~1.3% compared to RCA.

  • PDF

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Acute Toxicity Assessment of New Algicides, Thiazolidinedione Derivative (TD49) to Marine Ecosystem (신규 살조물질인 Thiazolidinedione 유도체 (TD49)의 해양생태계에 대한 급성독성평가)

  • Yim, Eun-Chae;Shin, Jun-Jae;Park, In-Taek;Han, Hyo-Kyung;Kim, Si-Wouk;Cho, Hoon;Kim, Seong-Jun
    • KSBB Journal
    • /
    • v.25 no.6
    • /
    • pp.527-532
    • /
    • 2010
  • A thiazolidinedione derivative, TD49 with the highly selective algicide to red tide was newly synthesized and its acute toxicity was examined in order to evaluate the effect on aquatic ecosystems of coast. Major three species having important role in the food chain of marine ecosystem, such as Skeletonema costatum of microalgae, Daphnia magna of crustacea, Paralichthys olivaceus of flatfish fingerling were employed for the acute toxicity assessment. $EC_50$ or $LC_50$ as the assessment criterion was investigated to each specie, and NOEC (No Observed Effect Concentration) and PNEC (Predicted No Effect Concentration) from most sensitive specie to toxicity of TD49 were further calculated. $EC_50$ of S. costatum in 96-hour, $EC_50$ of D. magna in 48-hour, and $LC_50$ of P. olivaceus in 72-hour for TD49 were $0.34\;{\mu}M$, $0.68\;{\mu}M$, and $0.58\;{\mu}M$, respectively. NOEC from the results of S. costatum was estimated to be $0.20\;{\mu}M$ and PNEC was estimated as 3.40 nM by applying factor value of 100 to $EC_50$ $0.34\;{\mu}M$ of S. costatum. In addition, it was revealed that Solutol used as the dispersing agent of TD49 had very little toxic influence under the concentration range of $0{\sim}0.4\;{\mu}M$ used in TD49 toxicity experiment. Although the estimated concentration of TD49 that will be sprayed onto the coastal field for the algicide is higher than NOEC value, it is considered that the spraying concentration would not be a considerable problem due to a dilution effect by tide at the opened coast.

The Coordinate Transformation of Digital Geological Map in accordance with the World Geodetic System (A Case Study of Chungju and Hwanggang-ri Sheets using ArcToolbox) (수치지질도의 세계측지계 좌표변환 (ArcToolbox를 이용한 충주 및 황강리 도폭의 사례))

  • Oh, Hyun-Joo
    • Economic and Environmental Geology
    • /
    • v.48 no.6
    • /
    • pp.537-543
    • /
    • 2015
  • In Korea, the use of world geodetic system(WGS) has been mandated in year 2010. Accordingly, the national geographic information institute(NGIS) provides the digital maps according to the WGS. Nevertheless, most of the digital geological maps are still based on the Tokyo Datum(TD). Therefore, users should conduct 2D/3D geological spatial analysis after converting the coordinates of digital geological maps to WGS. The conversion process is often tedious and troublesome for certain users. Therefore, in this study, the method to transform coordinate from TD to WGS using ArcToolbox is introduced for users not familiar with the process. For a better appreciation, the Chungju and Hwanggang-ri digital sheets of 1:50,000 scale was chosen as an example. Here, Chungju and Hwanggang-ri sheets were defined based on the TD-central origin and TD-east origin, respectively. The two sheets were merged after the transformation of TD-east origin of Hwanggang-ri to the TD-central origin, and eventually transformed to WGS-central origin. The merged map was found to match exactly with the digital map(Daeso 367041). The problem of coordinate determination in previous digital geological maps was solved effectively. The proposed method is believed to be helpful to 2D/3D geological spatial analysis of various geological thematic maps.

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

A Study on the Portfolio Performance Evaluation using Actor-Critic Reinforcement Learning Algorithms (액터-크리틱 모형기반 포트폴리오 연구)

  • Lee, Woo Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.467-476
    • /
    • 2022
  • The Bank of Korea raised the benchmark interest rate by a quarter percentage point to 1.75 percent per year, and analysts predict that South Korea's policy rate will reach 2.00 percent by the end of calendar year 2022. Furthermore, because market volatility has been significantly increased by a variety of factors, including rising rates, inflation, and market volatility, many investors have struggled to meet their financial objectives or deliver returns. Banks and financial institutions are attempting to provide Robo-Advisors to manage client portfolios without human intervention in this situation. In this regard, determining the best hyper-parameter combination is becoming increasingly important. This study compares some activation functions of the Deep Deterministic Policy Gradient(DDPG) and Twin-delayed Deep Deterministic Policy Gradient (TD3) Algorithms to choose a sequence of actions that maximizes long-term reward. The DDPG and TD3 outperformed its benchmark index, according to the results. One reason for this is that we need to understand the action probabilities in order to choose an action and receive a reward, which we then compare to the state value to determine an advantage. As interest in machine learning has grown and research into deep reinforcement learning has become more active, finding an optimal hyper-parameter combination for DDPG and TD3 has become increasingly important.

Analysis of C5G7-TD benchmark with a multi-group pin homogenized SP3 code SPHINCS

  • Cho, Hyun Ho;Kang, Junsu;Yoon, Joo Il;Joo, Han Gyu
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1403-1415
    • /
    • 2021
  • The transient capability of a SP3 based pin-wise core analysis code SPHINCS is developed and verified through the analyses of the C5G7-TD benchmark. Spatial discretization is done by the fine mesh finite difference method (FDM) within the framework of the coarse mesh finite difference (CMFD) formulation. Pin size fine meshes are used in the radial fine mesh kernels. The time derivatives of the odd moments in the time-dependent SP3 equations are neglected. The pin homogenized group constants and Super Homogenization (SPH) factors generated from the 2D single assembly calculations at the unrodded and rodded conditions are used in the transient calculations via proper interpolation involving the approximate flux weighting method for the cases that involve control rod movement. The simplifications and approximations introduced in SPHINCS are assessed and verified by solving all the problems of C5G7-TD and then by comparing with the results of the direct whole core calculation code nTRACER. It is demonstrated that SPHINCS yields accurate solutions in the transient behaviors of core power and reactivity.