• Title/Summary/Keyword: TC10

Search Result 2,120, Processing Time 0.024 seconds

Synthesis and in vitro evaluation of 99mTc-labeled tetraiodothyroacetic acid for tumor angiogenesis imaging

  • Kim, Hyunjung;Koo, Hyun-Jung;Choe, Yearn Seong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.1
    • /
    • pp.3-9
    • /
    • 2020
  • Tetraiodothyroacetic acid (tetrac) is a derivative of thyroid hormone T4 and causes anti-angiogenesis by blocking T4 binding to integrin αvβ3. In this study, we synthesized [99mTc]Tc-Cys-Asp-Gly(CDG)-tetrac and evaluated it in vitro as a tumor angiogenesis imaging ligand. The CDG was conjugated to tetrac as a chelator for technetium-99m labeling. The cold vial containing CDG-tetrac, sodium glucoheptonate, and reducing agent was completed under nitrogen-filled atmospheric glove bag. [99mTc]Tc-CDG-tetrac was synthesized in quantitative yield by heating the cold vial with [99mTc]TcO4- at 100℃ for 30 min. In vitro serum stability of [99mTc]Tc-CDG-tetrac was measured by incubating the radioligand in 50% fetal bovine serum at 37℃ and analyzing the incubation mixture by radio-TLC, which showed high stability over 6 h (≥ 98%). Cell binding study was carried out by incubating [99mTc]Tc-CDG-tetrac with human umbilical vein endothelial (HUVE) cells at 37℃ for 6 h. The cell binding of the radioligand increased from 100% at 0.5 h to 293.7% at 6 h in a time-dependent manner. For blocking study, the cells were incubated with the radioligand in the presence of either tetrac (20 μM) or cRGDyK (20 μM) at 37℃ for 4 h. The results demonstrated that the cell binding of the radioligand was inhibited by tetrac (19.1%) or cRGDyK (35.6%), indicating specific binding of the radioligand to integrin αvβ3. Thus, this study suggests that [99mTc]Tc-CDG-tetrac may be a potential radioligand for tumor angiogenesis imaging.

Effects of the Amounts of Terminalia chebula Retz Powder on the Quality of White Pan Breads (가자 분말 첨가량에 따른 식빵의 품질 변화)

  • Kim, Jeong-Sook;Jeong, Se-Hoon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.3
    • /
    • pp.430-436
    • /
    • 2009
  • This study was carried out to investigate the quality of white pan breads as affected by various amounts of Terminalia chebula Retz (TC) powder, in which the breads were prepared with 0, 2, 4, and 6% TC powder. The samples and a control bread were compared in terms of bread quality characteristics, including pH, baking loss rate, loaf volume index, moisture content, TBARS values, texture, color, and sensory qualities in order to determine the optimal amount of TC powder in the formulation. The pH levels of the bread samples containing TC powder ranged from 5.30 to 5.44, while the control bread had a pH of 5.68. The loaf volume index values of the samples prepared with 2~6% TC powder were lower than that of the control. After 7 days storage, the moisture content of the control bread had decreased by 14.4%, while the moisture contents of the breads with added TC powder had decreased by approximately 8~10%. The breads with TC powder had lower TBARS values as compared to the control bread. For texture characteristics, hardness increased with the addition of TC powder, and was especially increased in the sample containing 6% TC powder. Cohesiveness and springiness, however, decreased with the addition of TC powder. For color, lightness of the bread crust and crumb decreased with the addition of TC powder, whereas redness and yellowness increased. In terms of sensory quality, the bread containing 2% TC powder was preferred over the control bread, as estimated by appearance, crust color, taste, and overall quality, while the 6% TC bread had the lowest preference scores. These results suggest that the addition of 2% TC powder to white pan bread had optimal effects for improving shelf-life and enhancing bread quality.

  • PDF

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Optimization of Correction Factor for Linearization with Tc-99m HM PAO and Tc-99m ECD Brain SPECT (Tc-99m HMPAO와 Tc-99m ECD 뇌SPECT의 뇌혈류량 정량화에 사용되는 Linearization Algorithm의 Correction Factor 조사)

  • Cho, Ihn-Ho;Hayashida, Kohei;Won, Kyu-Chang;Lee, Hyoung-Woo;Watabe, Hiroshi;Kume, Norihiko;Uyama, Chikao
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.237-243
    • /
    • 1999
  • We conducted this study to find the optimal correction factor(${\alpha}$) of Lassen's linearization algorithm which has been applied for correction of flow-limited uptake at a high flow range in $^{99m}Tc$ d,l-hexamethylpropy leneamine oxime(HMPAO) and $^{99m}Tc$ ethyl cysteinate dimer(ECD). Ten patients with chronic cerebral infarction were involved in this study. We obtained the corrected $^{99m}Tc$ HMPAO and $^{99m}Tc$-ECD brain SPECT(single photon emission computed tomography) using the algorithm with ${\alpha}$ values that varied from 0.1 to 10 and compared the results with regional cerebral blood flow determined by positron emission tomography (PET-rCBF). The multi-modal volume registration by maximization of mutual information was used for matching between PET-rCBF and SPECT images. The highest correlation coefficient between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain uptake and PET-rCBF was revealed at ${\alpha}$ 1.4 and 2.1, respectively. We concluded that the ${\alpha}$ values of Lassen's linearization algorithm for $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain SPECT images were 1.4 and 2.1, respectively to indicate cerebral blood flow with comparison of PET-rCBF.

  • PDF

Comparison of Thallium-201 Scan and Tc-99m Sestamibi Scan in the Differential Diagnosis of Breast Mass (유방암 진단에 있어서 탈륨스캔과 Tc-99m MIBI 스캔의 비교)

  • Cho, Ihn-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Lee, Soo-Jung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.76-83
    • /
    • 1999
  • Purpose: We performed this study to compare T1-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Materials and Methods: Thirty-eight female patients underwent T1-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of T1-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared T1-201 and Tc-99m MIBI scans with pathologic results. Results: Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed T1-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18120), respectively. The sensitivity of early T1-201 scan was significantly higher than that of delayed T1-201 scan (p<0.05). The specificity of early and delayed T1-201 scan and Tc-99m MIBI scan were 73% (l1/15), 73% (l1/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed T1-201 scans. The size of fibroadenoma with false positive in early and delayed T1-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early T1-201 images, 15% (2/13) for delayed T1-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed T1-201 images (p<0.05). Conclusion: Early T1-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast Tc-99m MIBI scan was sensitive in detecting axillary lymph node metastasis in patients with breast cancer.

  • PDF

The Usefulness of Tc-99m MIBI SPECT in the Localization and the Assessment of Radiotherapy in Non-Small Cell Lung Cancer (비소세포 폐암의 국소화 및 방사선치료 판정에 있어 Tc-99m MIBI SPECT의 유용성)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Nam, Taek-Keum;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.186-191
    • /
    • 1994
  • Tc-99m MIBI, a lipophilic cation, was reported as a useful agent for localization of lung cancer. The effect of radiation therapy on the uptake of Tc-99m MIBI in lung cancer, however, was not well evaluated. The aim of the present study was to elucidate the usefulness of Tc-99m MIBI SPECT in the localization and the assessment of radiotherapy in non-small cell lung cancer. Twenty patients(19 males and 1 female, mean age 59, 16 squamous cell ca and 4 adenoca) were studied with Tc-99m MIBI SPECT before radiation therapy. Eleven patients(10 males and 1 female, mean age 59, 8 squamous cell ca and 3 adenoca) were repeated the study 1 month after the completion of radiation therapy(mean dose 6453cGy). All patients showed positive uptakes of Tc-99m MIBI in their tumors. One patient showed a hot uptake in atelectatic area. There was no difference of Tc-99m MIBI uptakes between squamous cell ca and adenoca either on planar or tomographic images. Tc-99m MIBI uptake ratios of squamous cell ca and adenoca were $1.50{\pm}0.16$ and $1.45{\pm}0.15$ on planar images, and $2.73{\pm}0.46$ and $2.54{\pm}0.37$ on tomographic images, respectively. The concordance between radiological change(chest x-ray and CT) and change of Tc-99m MIBI uptakes was 9/11 (81.8% ). In conclusion, Tc-99m MIBI SPECT was useful in the localization of tumor and the assessment of radiation therapy in non-small cell lung cancer.

  • PDF

Growth and Yield Variations among Generations in Field Cultivation of Virus-free Sweet Potato Plants (고구마 바이러스 무병묘의 세대간 생육 및 수량 변이)

  • Lee, Seung Yeob;Lee, Na Ra
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.376-382
    • /
    • 2014
  • This work was conducted to investigate the variation of growth and yield among three generations ($TC_0$, $TC_1$, and $TC_2$) in the field cultivation of virus-free sweetpotato (Ipomoea batatas) plants. Virus-free generations of three cultivars ('Matnami', 'Shinhwangmi', and 'Yeonhwangmi') were cultivated with $75{\times}25cm$ planting density on May 20th, covered with black vinyl film. At 30 days after planting, vine growth in $TC_0$, $TC_1$, and $TC_2$ was significantly increased as compared to the farmer's plant, and vine length in $TC_0$ showed the highest growth among treatments. At harvesting time after 120 days, vine diameter, number of node, and number of branch in $TC_0$, $TC_1$, and $TC_2$ were more increased than farmer's plant, but were not statistically significant. Fresh weight of shoot in $TC_0$, $TC_1$, and $TC_2$ was significantly increased as compared to the farmer's plant, but was not statistically significant among generations or cultivars. Number of tuber per plant and mean weight of tuber in $TC_0$ and $TC_1$ showed significant increasement, but that in $TC_2$ did not show significant difference as compared to the farmer's plant. Weight of tuber per plant in $TC_0$, $TC_1$, and $TC_2$ was significantly increased as compared to the farmer's plant. Marketable yield, percentage of marketable tuber, and percentage of small tuber (40 to 200g) in $TC_0$, $TC_1$, and $TC_2$ was significantly increased as compared to the farmer's plant. The large tuber over 300g showed the lowest percentage in $TC_0$. Marketable yield in $TC_2$ was significantly decreased as compared to $TC_0$, and was not significantly different as compared to the farmer's plant. Marketable yield in 'Matnami' was highest among cultivars. From this results, Farmers are required to renew every three years to maintain the yield and quality of virus-free plants. However, the exchange period of virus-free plants is desirable to renew every 2 or 3 years according to the degree of virus reinfection.

A Definition and Criterion on Typhoons Approaching to the Korean Peninsula for the Objective Statistical Analysis (객관적인 태풍 통계자료 구축을 위한 '한반도 근접 태풍'의 정의 및 기준 설정)

  • Moon, Il-Ju;Choi, Eu-Soo
    • Atmosphere
    • /
    • v.21 no.1
    • /
    • pp.45-55
    • /
    • 2011
  • A definition on the tropical cyclone (TC) that influenced the Korean Peninsula (KP), the KP-influence TC, is widely used in the TC communities, but its criterion is not clear mainly due to the ambiguity and subjectiveness of the term such as 'influence', which led to the inconsistent TC statistical analysis. This study suggests a definition and criterion on the TC approaching to the KP (KP-approach TC) additionally, which is more obvious and objective than the KP-influence TC. In this study, the criterion on the KP-approach TC is determined when the TC's center from the RSMC best track data encounters the box areas of $28^{\circ}N{\sim}40^{\circ}N$ and $120^{\circ}E{\sim}138^{\circ}E$. The range is chosen by finding a minimum area that includes all official KP-influence TCs except three TCs that affected the KP as a tropical depression (TD). Statistical analysis reveals that, among total 1,537 TCs that occur in the western North Pacific during 1951-2008, the KP-approach TC was 472, the KP-influence TC was 187, and the KP-landfall TC was 87. August was the month that the largest TCs approach and influence to the KP. Finally, this paper suggests to determine the KP-influence TC by the strong wind and heavy rain advisories in the KP based on the observation after the storm's passage.

Effect of Gamma Rays Emitted by the 99mTc on the CT Image (99mTc에서 방출되는 감마선이 CT 영상에 미치는 영향)

  • Park, Jae-Yoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.169-174
    • /
    • 2019
  • This study examines the changes that $^{99m}Tc$ causes to CT(Computed Tomography) images quantitatively when CT scans were continuously performed using $^{99m}Tc$. With the use of the CT, $^{99m}Tc$ 740MBq was injected into the Resolution Phantom and Water Phantom, and the tube voltage was changed with 80 kVp and 120 kVp, scanning before and after the injection. The result indicate, by comparing the Signal Intensity according to the presence or absence of the $^{99m}Tc$ injection with the tube voltage of 120 kVp and 80 kVp, a decrease of 0.173 and 0.241 was observed respectively and the spatial resolution increase of 0.090 and 0.109 was observed respectively. The order of the test should be considered because the gamma rays of the radiopharmaceutical used in the nuclear medicine test do not affect the CT while the effective half-life of the radiopharmaceuticals should be considered for the CT scan to reduce the influence of the gamma rays emitted after the nuclear medicine test, with the possibility to reduce the difference of the results.

[ $^{99m}Tc$ ] Generator Safety Simulation Based on GEANT4 (GEANT4를 이용한 $^{99m}Tc$ Generator 안전성 시뮬레이션)

  • Kang, Sang-Koo;Han, Dong-Hyun;Kim, Chong-Yeal
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Technisium $(^{99m}Tc)$ is one of the most widely used radioactive isotopes for diagnosis in nuclear medicine. In general, technisium is produced inside the so called $^{99m}Tc$ generator which is usually made out of lead to shield relatively high energy radiation from $^{99}Mo$ and its daughter nuclide $^{99m}Tc$. In this paper, a GEANT4 simulation is carried out to test the safety of the $^{99m}Tc$ generator, taking the Daiichi product with radioactivity of 500 mCi as an example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of shielding container should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated dose turned out to be less than the limit, satisfying the domestic regulation.

  • PDF