• Title/Summary/Keyword: TC&R

Search Result 436, Processing Time 0.026 seconds

Prediction of Post-operative Cardiopulmonary Function By Perfusion Scan (폐관류 검사를 이용한 폐절제술 후 심폐운동기능의 예측)

  • Ryu, Jeong-Seon;Lee, Ji-Young;Seo, Dong-Bum;Cho, Jae-Hwa;Lee, Hong-Lyeol;Yoon, Yong-Han;Kim, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.401-408
    • /
    • 2001
  • Background : Perfusion scans are accurate predictors of postoperative lung function. There are few previous studies aimed at predicting the postoperative exercise capacity using the perfusion scanning and those that did reported contradictory results. Method : We prospectively studied the preoperative spirometric, exercise tests and perfusion scans from in 49 consecutive patients who were admitted to Inha University Hospital with surgically resectable lung cancer from Jan. 1998 to Jun. 1999 29 patients who had any condition affecting the lung function and exercise capacity, or refused a surgical resection or a follow-up study were excluded. Spirometric and exercise tests were performed 6 months after operation in 20 patients. Results : The predicted postoperative $FEV_1$, FVC and TLC correlated well with the following corresponding postoperative values : $r_s$ and p value, 0.809 and 0.000 for the $FEV_1$ 0.895 and 0.000 for the FVC ; 0.741 and 0.006 for the TLC, respectively. The measured postoperative exercise values were slightly higher than the postoperative exercise values predicted, $VO_{2max}$ and $Wr_{max}$, were as 112% of $VO_{2max}$ predicted and 119% of $WR_{max}$ predicted. The change in $FEV_1$, FVC and TLC had a weak correlation with the change in $VO_{2max}$ and $WR_{max}$. Conclusion : The perfusion scan was a useful tool for predicting the postoperative exercise capacity. However, they had a tendency to underestimate the exercise capacity, especially in the patients who had a pneumonectomy. A weak correlation between the change in lung function and exercise capacity was observed.

  • PDF

Untersuchungen iiber Blutenknospenbildung bei Ribes nigrum L. (리베스(Ribes nigrum L. var. 'Rosenthals Langtraubige Schwarze') 식물의 화아분화에 관한 연구)

  • Yang, Deok Cho
    • Journal of Plant Biology
    • /
    • v.27 no.3
    • /
    • pp.179-189
    • /
    • 1984
  • Durch vergleichende Untersuchungen von Ribes nigrum L. var. 'Rosenthals Langtraubige Schwarze' zwischen $prim\"{a}rem$ und $sekund\"{a}rem$ Jugendstadium (P.J. und S.J.) eine vertiefte Einsicht in die beiden zeitlich unterschielich langen $Entwicklungsabl\"{a}ufe$ zu bekommen und auf diese Weise bessere Ansatzpunke $f\"{u}r$ die Regulierung der $Bl\"{u}tc-nknospeninduktion$ zu gewinnen, war das Ziel vorliegenden Untersuchungen. Diese Untersuchungen $f\"{u}hrten$ zu den flogenden Ergebnissen: Die Dauer der Jugendphase von Ribes nigrum L. betrug bei den P.J.-Pflanzen ca. 7 Monate, bei den S.J.-Pflanzen ca. 5 Monate. Die $Bl\"{u}hreife$-(Ripeness to flower)-setzte bei den P.J.-Pflanzen erst beim 20. Nodium ein, bei den S.J.-Pflanzen bereits beim 5. Nodium. Das $f\"{u}hrte$ dazu, da${\beta}$ bei gleicher Nodienzahl die P.J.-Pflanzen weniger $Bl\"{u}te-nknospen$ angesetzt hatten als die S.J.-Pflanzen. Die erste $Bl\"{u}tenknospendifferenzierung$ setzte bei den P.J.-Pflanzen in der oberen Triebmitte etwa am 30. Nodium ein, beiden S.J.-Pflanzen bereits in der unteren Tricbmitte etwa am 20. Nodium. Bie den P.J.-Pflanzen waren die untersten 20. Nodien immer steril, $w\"{a}hrend$ bei den S.J.-Pflanzen $h\"{a}uflgsten$ an dem ersten Nodium $\"{u}ber$ der Basis fertil waren. In allen Versuchen hat sich gezeigt, da${\beta}$ der Wachstumsabschlu${\beta}$ -(Bildung einer Terminal Knospe)-, der bei Ribes nigrum L. durch Kurztag eingeleitet wird, bei den P.J.-Pflanzen langsammer als bei den S.J.-Pflanzen erfolgt. Dies $f\"{u}hrt$ dazu, da${\beta}$ die Pflanzen der $sekund\"{a}ren$ Jugendphase auf die photokybernetischen Stimulation empfindlicher reagieren als die der $prim\"{a}ren$ Jugendphase. Alle untersuchten Versuchsdaten $f\"{u}hren$ zu dem Schlu${\beta}$, da${\beta}$ die Wurzelgibberelline $(GA_n)$ keinen Einflu${\beta}$ auf die $Jugendsterilit\"{a}t$ ($Basissterilit\"{a}t$) haben. Aus den Untersuchungen geht hervor, da${\beta}$ die induktive Ma${\beta}$nahme zur Beschleunigung der $Bl\"{u}tenknospenbildung$ $f\"{u}r$ eine $Z\"{u}chtungsselektion$ erst dann eingesetzt werden sollen, wenn die P.J.-Pflanzen mehr als 20 Nodien ausgebildet haben.

  • PDF

A Study on the Evolution of 3,4-DCA and TCAB in Some Selected Soils(Part II) -Degradation of $^{14}C-3,4-DCA\;and\;^{14}C-TCAB$- (수종토양중(數種土壤中)에서 3,4-DCA 및 TCAB의 변화(變化)에 관(關)한 연구(硏究)(제2보(劑二報)) -$^{14}C-3,4-DCA$$^{14}C-TCAB$ 의 분해(分解)-)

  • Lee, Jae-Koo;Fournier, J.C.
    • Applied Biological Chemistry
    • /
    • v.21 no.2
    • /
    • pp.71-80
    • /
    • 1978
  • In an attempt to elucidate the fate of 3,4-DCA and TCAB in various French soils, uniformly $^{14}C-ring-labeled$ 3,4-DCA and TCAB mere utilized and the following results obtained. 1) The rate of breakdown of $^{14}C-3,4-DCA$ into $^{14}CO_2$ was relatively higher in the early stage than that in the later stage. In 6 months of incubation in alkaline soil (pH 7.9), the rate was as high as 6.5% at dose 1 (1.5 ppm) and as low as 1.92% at dose 2(94 ppm), whereas in organic acid soil (pH 5.5) the rate was 4.91% at dose 1 and 4.24% at dose 2, respectively, without making any great difference between the two levels. 2) At dose 1, 47.70% of the initial radioactivity of $^{14}C-3,4-DCA$ was bound to soil in organic acid soil and 29.49% bound in alkaline soil, whereas at dose 2, 38.40% in organic acid soil and 20.30% in alkaline soil, respectively. 3) The amount of formation of $^{14}C-TCAB$ from $^{14}C-3,4-DCA$ seems to depend largely on the concentration of 3,4-DCA applied rather than on soil types. At dose 2, the amount was 50% of the total radioactivity extracted in organic acid soil and 30% in alkaline soil, corresponding to 1.8% and 1.4% of the initial radioactivity applied to soil, respectively. Cis-TCAB also seemed to be formed at dose 2 in both soils. Meanwhile, at dose 1, even though $^{14}C-TCAB$ was detected in trace on tlc and glc in both soils, the amount does not exceed 2 to 3% of the radioactivity extracted, corresponding to 0.05 to 0.1% of the initial radioactivity. 4) The rate of breakdown of $^{14}C-TCAB$ into $^{14}CO_2$ ranged from 0.05 to 0.20% in all the four soils. Most of the applied $^{14}C-TCAB$ remained intact after 3 months, not producing any detectable metabolites. 5) The fact that much more $^{14}C-TCAB$ was adsorbed to alkaline soil than to the other soils strongly indicates that in alkaline condition trans-isomer was converted tocisisomer which has the higher adsorption affinity than the former.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Viabilities of Biopsied Mouse Embryos after Ultrarapid Refreezing and Thawing (미세조작된 생쥐수정란의 초급속 재동결융해 후 생존성)

  • 신상태;임준호;강만종;한용만;이경광
    • Korean Journal of Animal Reproduction
    • /
    • v.20 no.2
    • /
    • pp.207-214
    • /
    • 1996
  • To examine the developmental capacity of manipulated embryos after ultrarapid refreezing and thawing, mouse embryos were biopsied at 4-cell stage, frozen twice at 4-cell and morula stages, respectively, and then transferred to rec-ipients. Single blastomeres were biopsied from 4-cell embryos by a modified aspiration method. Biopsied 4-cell embryos were equilibrated into freezing medium at room temperature for 2.5 min, loaded into 40 $\mu$I of freezing medium in 0.25 ml plastic straw and then directly immersed into liqiud nitrogen. Freezing medium for 4-cell embryos consisted of 4.0 M ethylene glycol and O.25 M sucrose in dPBS supplemented with 6 mg/lm BSA. Morulae were frozen into freezing medium containing 5.0 M glycerol instead of ethylene glycol. Thawing was conducted by agitating each straw in 3TC water for 20 sec. The c content of each straw was expelled into 0.5 ml of dilution medium, which consisted of 0.25 M sucrose and 3 mg/ml BSA in dPBS. The thawed embryos were rehydrated in dilution medium for 10 min, washed 3 times with dPBS and then cultured in M16 medium at 37$^{\circ}C$, 5% CO$_2$ in air. Blastocysts that developed from frozen or refrozne biopsied embryos were transferred to recipients on Day 3 of pseudopregnancy, respectively. In vitro and in vivo developmental rates of the biopsied and intact 4~cell embryos after freezing and thawing were 78 (10l/130) and 25% (10/40), and 91 (114/125) and 30% (12/40), respectively. Although the rates of in vitro development of biopsied and intact embryos to blastocyst stage were significantly different after freezing and thawing (P

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF