• Title/Summary/Keyword: TBDMS derivatization method

Search Result 15, Processing Time 0.038 seconds

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Paper Materials (기체 크로마토그래피/질량분석기를 이용한 종이류 중 알킬페놀류, 클로로페놀류 및 비스페놀 A 정량)

  • Kim, Hyub;Kim, Jin-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrom-etry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. Also, solid -phase extraction (SPE) with XAD -4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The SIM responses were linear with the correlation coefficient varying 0.9717 ∼ 0.9995 (isoBOC derivatization), and 0.9842 ∼ 0.9980 (TBDMS derivatization). The recoveries were 82.4 ∼ 108.8%) by area ratio of phenanthrene -d$\_$10/ vs bisphenol A-d$\^$l6/. (isoBOC derivatization and TBDMS derivatization) The range of concentrations was respectively, 0.95 ∼ 1.44 ng/g in 2,4-dichlorophenol, 1.01 ∼ 1.17 ng/g in t-butylphenol,2.17 ∼ 5.84 ng/g in pentachlorophenol, 12.68 ∼ 14.88 ng/g in nonylphenol and 30.84 ∼ 153.72 ng/g in bisphenol A.

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

Determination of 11 Phenolic Endocrine Disruptors using Gas Chromatography/Mass Spectrometry-Selected Ion Monitoring in Five Selected Wastewater Influents

  • Kim, Hyub
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.216-223
    • /
    • 2008
  • An efficient method for the simultaneous determination of eleven phenolic endocrine-disrupting chemicals (EDCs) present in wastewater influent samples was described. The 11 phenolic EDCs including alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) following two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. The wastewater influent samples containing the 11 EDCs were adjusted to pH 2 with $H_2SO_4$ and then cleaned up with n-hexane. Next, they were subjected to solid-phase extraction (SPE) with XAD-4 resin and subsequently converted to isoBOC or TBDMS derivatives for sensitivity analysis with gas chromatography/mass spectrometry-selected ion monitoring (GC/MSSIM). Following isoBOC derivatization and TBDMS derivatization, the recoveries were 86.6-105.2% and 97.6-142.7%, the limits of quantitation (LOQ) for the 11 phenolic EDCs for SIM was 0.001-0.050 ng/mL and 0.003-0.050 ng/mL, and the SIM responses were linear with the correlation coefficient varying by 0.9717-0.9995 and 0.9842-0.9980, respectively. When these methods were applied to five selected wastewater influent samples, for isoBOC derivatization and TBDMS derivatization the ranges of concentration detected were 0.2-99.6 ng/mL and 0.4-147.4 ng/mL, respectively.

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.26 no.9
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

Comparison of isoBOC derivatives, TBDMS derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A potential field-screening applications of GC/MS-SIM

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.235.2-236
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison: EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. (omitted)

  • PDF

Rapid Gas Chromatographic Profiling and Screening of Acidic Non-Steroidal Antiinflammatory Drugs in Biological Samples

  • Kim, Kyoung-Rae;Shin, You-Jin;Shim, Won-Hee;Myung, Seoung-Won
    • Archives of Pharmacal Research
    • /
    • v.17 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • The solid-phase extraction (SPF) with subsequent tert-butyldimethylsilyl (TBDMS) derivatization was investigated for the rapid profiling and screening of various carboxylated non-steroidal antiinflammatory drugs (NSAIDs) simultaneously in biological fluid samples. Compared to the conventional SPF in adsorption mode using Chromosorb 102, Chromosorb 107, Carbopak B and Thermosorb, the SPF in partition mode using Chromosorb P as the adsorbent, and ethyl acetate/methylene chloride as the eluting solvents provided hightest overall recovenies of the NSAIDs from aqueous solutions with good precision. The solid-phase extracted NASIDs were silylated with N-methyl-N-(tert-butyldimethylsily)trifuoroacetamide to TBDMS derivatives and directly analyzed by capillary gas chromatography and gs chromatography-mass spectrometry. The usefulness of the present method was examined for the profilling and screening of saliva, serum and urine samples for various NSAIDs simultaneously.

  • PDF

Dertermination of Alkylphenols, Chlorophenols and Bisphenol A in Various Samples by Freezing Filtration and GC/MS-SIM

  • Kim, Hyub
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.68.1-68.1
    • /
    • 2003
  • A method for determination 11 endocrine disrupting chemicals of phenols in various samples was deloped. The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization method and tert-butyldimethylsilyl (TBDMS) derivatization method. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then acetonitrile layer was refrigerated at -60$^{\circ}C$ for 2 hours (freezing filtration). (omitted)

  • PDF

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Papers Materials

  • Kim, Hyub;Kim, Jin-Ho;Kim, Yong-Hwa
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.120.2-121
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. (omitted)

  • PDF

A Sensitive Determination of Plasma Free Fatty Acids Following Tert-butyldimethylsilyl Derivatization using Gas Chromatography-Mass Spectrometry for Screening of Fatty Acid Oxidation Disorders (지방산대사이상질환 스크리닝을 위한 TBDMS 유도체화 후 GC-MS를 이용한 혈장 중 유리지방산의 분석)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.2
    • /
    • pp.39-47
    • /
    • 2017
  • Purpose: A sensitive gas chromatography mass spectrometry (GC-MS) method was developed for screening of fatty acid oxidation disorders. Methods: The assay utilized a simple protein precipitation with sulfosalicylic acid followed by tert-butyl dimethylsilyl (TBDMS) derivatization of hydroxyl functional group by N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Results: Calibration curves of spiked pooled plasma showed a linear relationship in the range of 0.01 ng -2 mg with correlation coefficient value greater than 0.98. Limits of detection (LOD) and limits of quantification (LOQ) were found in the range of 0.9-8.8 ng and 9-88 ng, respectively. Conclusion: The new developed method might be useful for a rapid, sensitive screening of inherited fatty acid oxidation disorders. In addition, the method expected to be one of the alternative method for screening newborns of metabolic disorders in the laboratories where expensive MS/MS is unavailable.

  • PDF