• Title/Summary/Keyword: TAN-TAN

Search Result 2,180, Processing Time 0.028 seconds

Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement (Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석)

  • Kim, Jeong-Tae;Kim, Woo-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.

Effects of Temperature and Stocking Density on the Ammonia Excretion Rate of Red Seabream, Pagrus major

  • Harwanto, Dicky;Oh, Sung-Yong;Kim, Chong-Kwan;Gultom, Victor David Nico;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • v.32 no.1
    • /
    • pp.63-71
    • /
    • 2010
  • An experiment was conducted to investigate the effects of temperature and stocking density on daily patterns and rates of total ammonia nitrogen (TAN) excretion in juvenile red seabream Pagrus major (mean body weight: 29.0 g) under fasting and feeding conditions. Fish were acclimated over 7 days under four different temperatures (10, 15, 20, and $25^{\circ}C$) and at two different densities (5.5 and $11.0\;kg\;m^{-3}$). Each treatment had three replicates and a total of 216 fish were used. After 72 hours starvation, endogenous TAN excretion was measured for each temperature and density. To investigate exogenous TAN excretion, fish were handfed a commercial diet containing 51.6% crude protein twice a day for 7 days, at 08:00 and 16:00. Water was sampled from both inlets and outlets of chambers every 2 hours over a 24 hour period. Both endogenous and exogenous TAN excretion increased with increases in temperature and density (P<0.05). Mean daily endogenous TAN excretion rates at 10, 15, 20, and $25^{\circ}C$ were 88.8, 101.1, 125.0, and $143.3\;mg\;TAN\;kg^{-1}\;d^{-1}$ at low density, and 105.2, 119.2, 141.5, and $168.8\;mg\;TAN\;kg^{-1}\;d^{-1}$ at high density, respectively. Mean daily exogenous TAN excretion rates at 10, 15, 20, and $25^{\circ}C$ were 343.5, 403.7, 535.7, and $601.7\;mg\;TAN\;kg^{-1}\;d^{-1}$ at low density, and 391.9, 479.7, 611.9, and $683.4\;mg\;TAN\;kg^{-1}\;d^{-1}$ at high density, respectively. The exogenous TAN excretion rate peaked 10~12 hours after the first feeding under all temperatures and densities. The TAN loss for ingested nitrogen increased with increases in temperature and density (P<0.05), ranging from 27.9 to 50.1% at low density and 31.7 to 56.9% at high density. This study provides empirical data for estimating ammonia excretion and managing the culture of red seabream under the given temperatures and densities.

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

The System of Sewage and Domestic Wastewater Treatment Plants in Tan-Sui River Basin

  • Ko, Chun-Han
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.26.2-39
    • /
    • 2002
  • Tan-Sui River Basin covers Taipei metropolitan area of 2,726 square kilometers with more than six million residents. Since 1988, Taiwan government started to plan and construct an integrated sewerage system, consisted by both separated and concentrated trunk sewers, wastewater treatment plants and ocean outfalls. This presentation will introduce the master plan and major facilities of Tan-Sui River Basin sewerage system. Other measures to protect general water quality and the environment of adjacent river basin area of Tan-Sui River and her tributaries by Taiwan EPA will be presented as well.

  • PDF

Prediction of water quality in Tan stream of the Han river (장래 탄천수질과 한강본류에 미치는 영향 예측)

  • 신정식;정종흡;오경두;나규환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2001
  • The water quality simulation was carried out to predict water quality in Tan stream of the Han river using water quality model, QUAL2E. In the end, the future variations in water quality of Tan stream were simulated and the prediction of the impacts of Tan stream on water quality in the Han river was carried out by applying the Tan stream simulation results into the model. The results are as follows. The predicted results of future water quality of Tan stream suggested that the concentrations of BOD, T-N and T-P at Chungdam bridge would increase to 0.68~0.77 mg/$\ell$, 1.33~1.62 mg/$\ell$ and 0.05~0.06 mg/$\ell$, respectively in 2006 and 2011 and that with the implementation of advanced treatment in Sungnam and Tanchun sewage treatment plants, the concentration of T-N would be reduced more as the amount of treated sewage increase, while the concentration of T-P would stay 0.49 mg/$\ell$. The results obtained from simulation of the impacts of future Tan stream water quality improvement on the main stream of the Han river showed that with implementation of advanced treatment in both Sungnam and Tanchun sewage treatment plants, the concentration of T-N, T-P and chlorophyll-a at Hangang bridge and Heangju bridge would be reduced by 11.6%, 7.7% and 20.9%, respectively in 2..6 and by 13.6%, 9.4% and 22.2%, respectively in 2011, which indicates that the effect on the reduction of T-N and T-P would be relatively significant while the effect on the decrease of algae would be slight.

  • PDF

Outcomes of an outpatient home-based prehabilitation program before pancreaticoduodenectomy: A retrospective cohort study

  • Kai Siang Chan;Sameer Padmakumar Junnarkar;Bei Wang;Yen Pin Tan;Jee Keem Low;Cheong Wei Terence Huey;Vishalkumar Girishchandra Shelat
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.4
    • /
    • pp.375-385
    • /
    • 2022
  • Backgrounds/Aims: Prehabilitation aims for preoperative optimisation to reduce postoperative complications. However, there is a paucity of data on its use in patients undergoing pancreaticoduodenectomy (PD). Thus, this study aims to evaluate the outcomes of a home-based outpatient prehabilitation program (PP) versus no-PP in patients undergoing PD. Methods: This retrospective cohort study compared patients who underwent PP versus no-PP before elective PD from January 2016 to December 2020. Inclusion criteria for PP were < 65 years or 65-74 years with FRAIL score < 3. No-PP included dietician, case manager and anesthesia review. PP included additional physiotherapy sessions, caregiver training and interim phone consultation. Univariate and multivariate analysis were used to evaluate length of stay (LOS), morbidity, 30-day readmission, and 90-day mortality. Results: Seventy-one patients (PP: n = 50 [70.4%]; no-PP: n = 21 [29.6%]) were included in this study. Median age was 65 years (interquartile range [IQR]: 58-72 years). Majority (n = 58 [81.7%]) of patients underwent open surgery. Ductal adenocarcinoma was the most common histology (49.3%). Patient demographics were comparable between both groups. Overall median LOS was 11.0 days (IQR: 8.0-17.0 days). Compared to no-PP, PP was not independently associated with reduced intra-abdominal collections (odds ratio [OR]: 0.43; 95% confidence interval [CI]: 0.03-6.11, p = 0.532), major morbidity (OR: 1.31; 95% CI: 0.09-19.47; p = 0.845) or 30-day readmission (OR: 3.16; 95% CI: 0.26-38.27; p = 0.365). There was one (1.4%) 30-day mortality. Conclusions: Our outpatient PP with unsupervised exercise regimes did not improve postoperative outcomes following elective PD.

The degradation of insulation oil in power transformers by the evolution of gases, Tan $\delta$, moisture and total acid number (가스량, Tan $\delta$, 수분량, 전산가에 의한 유침 전력 변압기의 열화현상에 관한 연구)

  • Choi, Jong-Kab;Han, Min-Koo;Kwon, Tae-Won;Yun, Yong-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.159-163
    • /
    • 1989
  • The various degradation phenomena, such as the evolution of gases, tan $\delta$, moisture content and total acid number in power transformer insulation oil, have been measured and analyzed. Mineral oil has been degraded at laboratory by the forced thermal stress of $60^{\circ}C$ and $90^{\circ}C$ respectively. Thermal aging oil has been degraded about 17, 34, 72 days. Also, we extracted insulation oil from working transformers. We measured gases dissolved in samples, tan $\delta$, moisture content, total acid number. Activation energy and resistivity is calculated from them. It is found that gases and tan $\delta$ increases as partial discharge and total acid number increases and that conductivity of the sample increases as activation energy increases.

  • PDF

The Dielectric loss Properties of Mini-model Superconducting Cable (Mini-model 초전도 케이블의 유전손실 특성)

  • 김영석;곽동순;한철수;김해종;김동욱;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.946-951
    • /
    • 2003
  • A high-Tc superconducting cable(HTS cable) is expected as an underground power line supplying the electrical power the densely populated city in future. The electrical insulation is very important for develop HTS cable system because it is operated a high voltage and in cryogenic temperature. We manufactured a mini-model cable and measured a tan$\delta$ of cable using schering bridge. The tan$\delta$ of PPLP was lower than that of Tyvek and Kraft at a given temperature, the tan$\delta$ of PPLP was 1.16${\times}$10-3. According to the increase of electric stress the tan$\delta$ increased because partial discharge occurred inside butt gap of mini-model cable. However, the tan$\delta$ decreased by increase of liquid nitrogen pressure. This reason is thought by decrease of part discharge between butt gap by increase of liquid nitrogen pressure.

Nitrification Efficiency in Fixed Film Biofilters using Different Filter Media in Simulated Seawater Aquarium System

  • Peng, Lei;Jo, Jae-Yoon
    • Journal of Aquaculture
    • /
    • v.16 no.4
    • /
    • pp.203-209
    • /
    • 2003
  • Nitrification efficiency of fixed film biofilters with sand, loess bead, and styrofoam bead in biofilter columns of 1-m height and 30 cm width was studied. Synthetic wastewater was continuously supplied to the culture tank to maintain total ammonia nitrogen (TAN) concentration in the inflow water at around 8 mg/L. The hydraulic loading rate was set at 200 ㎥/$m^2$/day. TAN conversion was stabilized after about 90 day conditioning for all the selected filter media but with net accumulations of nitrite. On the volumetric basis, conversion rates of TAN and nitrite were the highest in styrofoam bead filter. Mean volumetric TAN conversion rates in the final samples were 682, 269, and 79 g TAN/㎥/day in the styrofoam bead, sand and loess bead filters, respectively. Low gravity and cost of styrofoam bead render the handling easier and more cost-effective.

An Amendment of the VLF tanδ Criteria to Improve the Diagnostic Accuracy of the XLPE-insulated Power Cables (XLPE 절연케이블의 열화진단 정확도 향상을 위한 VLF tanδ 판정기준 개선)

  • Lee, Jae-Bong;Jung, Yeon-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1644-1651
    • /
    • 2010
  • VLF $tan{\delta}$ diagnosis technology is introduced in IEEE Std 400 and proposed as evaluation criterion in an effective way of detecting water tree which mainly causes the failure of XLPE insulated cables. In order to inspect the accuracy of the VLF $tan{\delta}$ method for XLPE insulated power cables in Korean distribution system, diagnosis for 41 cables which were being serviced in the fields has been carried out and they were removed for AC breakdown voltage test after. Regarding the 41 cables, it was hard to confirm any relation between the VLF $tan{\delta}$ values and AC breakdown voltages and also water tree in the insulation was not detected. However, the other cables were failed several days after the diagnosis of the 41 cables. Water trees were found and their VLF $tan{\delta}$ values were also much higher than the criterion of IEEE standard. It has been ascertained that we need to change the IEEE criteria in order to improve the accuracy of detecting water trees by additional analyzing of field examples of failure and case studies from overseas countries and therefore amended VLF $tan{\delta}$ test voltage and evaluation criteria have been proposed.