A Study on the Dielectric Polarization of $ITO/Alq_3/Al$ Structure Organic Light-emitting Diodes ($ITO/Alq_3/Al$ 구조 유기 발광 소자의 유전분극 현상의 연구)

  • Oh, Yong-Cheul;Shin, Cheol-Gi;Kim, Chung-Hyeak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.73-77
    • /
    • 2008
  • We have investigated dielectric polarization in organic light-emitting diodes using 8-hydroxyquinoline aluminum($Alq_3$) as an electron transport and emissive material. We analyzed the dielectric polarization of organic light-emitting diodes using characteristics of impedance and equivalent circuit of $ITO/Alq_3/Al$. Impedance characteristics was measured complex impedance Z and phase ${\theta}$ in the frequency range of $1{\times}40Hz\;to\;1{\times}10^8Hz$. We obtained complex electrical conductivity, dielectric constant, and loss tangent(tan${\delta}$) of the device at room temperature. And, we obtained the equivalent circuit of $ITO/Alq_3/Al$ through analyzing dielectric constant and dielectric loss tangent. From these analyses, we could interpret a conduction mechanism and dielectric polarization.

Adaptive Tracking Control of Two-Wheeled Welding Mobile Robot with Smooth Curved Welding Path

  • Bui, Trong-Hieu;Chung, Tan-Lam;Kim, Sang-Bong;Nguyen, Tan-Tien
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1682-1692
    • /
    • 2003
  • This paper proposes an adaptive controller for partially known system and applies to a two-wheeled Welding Mobile Robot (WMR) to track a reference welding path at a constant velocity of the welding point. To design the tracking controller, the errors from WMR to steel wall is defined, and the controller is designed to drive the errors to zero as fast as desired. Additionally, a scheme of error measurement is implemented on the WMR to meet the need of the controller. In this paper, the system moments of inertia are considered to be partially unknown parameters which are estimated using update laws in adaptive control scheme. The simulations and experiments on a welding mobile robot show the effectiveness of the proposed controller.

Flood Runoff Analysis on the Anseong-cheon watershed using TOPMODEL and Muskingum method. (TOPMODEL과 Muskingum 기법을 이용한 안성천유역의 홍수유출분석)

  • Kwon, Hyung-Joong;Kim, Seong-Joon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.289-292
    • /
    • 2002
  • In this study, a topography based hydrologic model (TOPMODEL) was tested on the Anseong-cheon watershed. Pit in watershed was removed by liner trend surface interpolator. The DTM Analysis program is used to derived a distribution of ln($a/tan{\beta}$) values from DEM (Digital Elevation Model) using the MDF (Multiple Direction Flow) algorithm of Quinn et al (1995). Current TOPMODEL program limits are number of time step, ln($a/tan{\beta}$) increment, delay histogram ordinate and size of subcatchment pixel maps. Therefore, TOPMODEL is not suitable for application of large watershed. Muskingum method and watershed division enhance grid pixel resolution for rainfall-runoff simulation accuracy.

  • PDF

A NON-COMPACT GENERALIZATION OF HORVATH'S INTERSECTION THEOREM$^*$

  • Kim, Won-Kyu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.32 no.2
    • /
    • pp.153-162
    • /
    • 1995
  • Ky Fan's minimax inequality is an important tool in nonlinear functional analysis and its applications, e.g. game theory and economic theory. Since Fan gave his minimax inequality in [2], various extensions of this interesting result have been obtained (see [4,11] and the references therein). Using Fan's minimax inequality, Ha [6] obtained a non-compact version of Sion's minimax theorem in topological vector spaces, and next Geraghty-Lin [3], Granas-Liu [4], Shih-Tan [11], Simons [12], Lin-Quan [10], Park-Bae-Kang [17], Bae-Kim-Tan [1] further generalize Fan's minimax theorem in more general settings. In [9], using the concept of submaximum, Komiya proved a topological minimax theorem which also generalized Sion's minimax theorem and another minimax theorem of Ha in [5] without using linear structures. And next Lin-Quan [10] further generalizes his result to two function versions and non-compact topological settings.

  • PDF

Development of the speed-measurement device of motor in a crane (기중기의 모터속도 측정장치 개발)

  • 김강철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.638-641
    • /
    • 2000
  • The conventional motor in a crane has a tan generator to feed back the number of turns. The tan generator is contacted to a motor shaft through the coupling. Don has been often generated because the coupling has worn out while the motor is turning. In this paper, we design the speed-measurement device of motor in a un. The device is composed of PIC16F84 controller, photo-sensor, and analog-to digital converter. The photo sensor measures the turn of a motor without contact so the device decreases the probability of errors. And The device can acknowledge the turn direction of the motor with a gin81e senor and two color reflectors.

  • PDF

Study on Diagnosis for Transformers by Tan $\delta$ and Moisture of Insulation Oil According to Thermal Aging (절연유의 열열화에 따른 Tan $\delta$와 수분의 변화에 의한 변압기의 예방진단 연구)

  • HwangBo, Seung;Han, Min-Koo;Kwak, Hee-Ro;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.241-245
    • /
    • 1988
  • This paper reports the experiments regarding to diagnosis techniques for power transformers by measuring dissipation factor and moisture contents of mineral oils. Thermal aging environments of mineral oils were varied by the specially designed systems. Thermal aging of elevated temperature of $90^{\circ}C$ was performed for about 240 and 460 hours, respectively. Dissipation factor, permittivity, and water content were measured. Our test samples were not exposed to air. Dissipation factor increased while permittivity did not change. The level of dissipation factor determining the insulating quality of mineral oil was compared with the previous results of resistivity and several correction factor.

  • PDF

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.2
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

Dielectric Properties Analysis in Paraelectric $ZrTiO_4$Thin Films (상유전 $ZrTiO_4$박막의 유전특성 분석에 관한 연구)

  • 허진희;김경해;이준신
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.547-549
    • /
    • 2001
  • The dielectric constants and dielectric losses of ZrTiO$_4$thin films deposited by DC magnetron reactive sputtering were investigated. The paraelectric properties were measured in the 100kHz range. As the deposition temperature increased (up to 67$0^{\circ}C$), the dielectric losses (tan$\delta$) decreased (down to 0.017$\pm$0.007), while the dielectric constants ($\varepsilon$) were in the range of 35$\pm$7. Post annealing at 80$0^{\circ}C$ in oxygen for 2h reduced tan$\delta$ down to 0.005$\pm$0.001, higher than those of well-sintered bulk ZrTiO$_4$.

  • PDF

Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers (배전용 변압기의 진단을 위한 위상 검출 장치의 개발)

  • Kim, Young-Chun;Choi, Do-Hyuk;Yoon, Yong-Han;Min, Kyeoung-Rae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

Field Test Results for Water-tree Diagnosis Technologies of Domestic Underground Distribution Cable (국내 지중배전케이블에 대한 수트리 열화진단기술 현장 시험 결과)

  • Lee, Jae-Bong;Joung, Jong-Man;Park, Chul-Bae;Lee, Jae-Ok;Mok, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.506-507
    • /
    • 2006
  • 1986년 제조되어 국내 지중배전계통의 관로에서 20년간 사용된 CNCV케이블에 대하여 IRC(Iso-thermal Relaxation Current) 측벙법을 사용하는 진단장비와 0.1Hz 극저주파 Tan-delta 측정법을 사용하는 진단장비로 케이블의 수트리 열화 진단을 시행하고 철거한 후 교류파괴전압시험을 수행하였다 각 진단장비의 진단결과와 교류파괴전압시험 결과, 수트리의 존재여부를 비교하였다. VLF Tan-delta 측정법을 사용하는 진단장비가 교류파괴전압시험결과, 수트리의 유무 둥과 상관성이 비교적 높게 나타났다. 통계적으로 신뢰성을 확보할 수 있도록 지속적인 비교 검증시험을 추진할 계획이다.

  • PDF