Characteristics of Dissipation Factor in Large Generator Stator Bars (대용량 발전기 고정자 바의 유전정접 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.402-403
    • /
    • 2009
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 11460h, dissipation factor($tan{\delta}$) test was performed on No. 1 and No.2 model stator bars. The ${\Delta}tan{\delta}$ of No. 1 and No. 2 stator bars increased with increased in aging time.

  • PDF

The Management of Pancreatic Fistula Complicated by Gastric Fistulation Following Emergency Splenectomy

  • Huei, Tan Jih;Lip, Henry Tan Chor;Thou, Chow Sing;Mohamad, Yuzaidi;Alwi, Rizal Imran
    • Journal of Trauma and Injury
    • /
    • v.33 no.1
    • /
    • pp.43-47
    • /
    • 2020
  • Pancreatic and gastric fistulas are rare complications of emergency splenectomy, and it is extremely rare for a pancreatic fistula to be further complicated by a fistulation into the stomach. Here, we present a case of pancreatogastric fistula in a 60-year-old man who experienced polytrauma due to a blunt mechanism. He underwent emergency splenectomy for splenic injury and developed a pancreatic fistula as a complication. A percutaneous endoscopic procedure was performed to drain the fistula, after which he developed a pancreatogastric fistula as a further complication. A double-pigtail stent was inserted via gastroscopy into the fistula tract to allow internal drainage of the pancreatic collection into the stomach cavity. When a pancreatic fistula is complicated by gastric fistulation, endoscopic stenting of the pancreatogastric fistula tract for internal drainage is an effective treatment option.

Prediction of Final Settlement on Soft Ground (연약지반에서 최종침하량의 예측방법)

  • 임성훈;강예묵;이달원;김지훈
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.449-454
    • /
    • 1998
  • This study was performed of the research for accurate prediction of consolidation settlement at initial consolidation time. In order to analysis the program is developed which is able to analysis behavior of settlement caused by gradual load increment, and simulated consolidation using whole measured settlement data and that from beginning of embankment to end of it. The former result agrees with measured data and the latter it overestimated 13% larger than measured data. It was found the time which takes to be eliminated effect of gradual step load. This method is compared with the results from Asaoka, Hyperbolic and Tan's hyperbolic method respectively Asaoka and Tan's hyperbolic methods we in good agreement with this method. But classical hyperbolic method overestimated about 32%.

  • PDF

Carbon Medicine in Ancient China

  • Yang, Hongyan;Fu, Zengxiang;Huang, Xingli;Ma, Binrui
    • Carbon letters
    • /
    • v.6 no.4
    • /
    • pp.255-256
    • /
    • 2005
  • In traditional Chinese medicine, some herbs are used after toasting or roasting. The process is called "Zhi Tan" in Chinese, which means charring, and the herbs after the treatment is called carbon medicine. Carbon medicine is widely used to arrest bleeding in traditional Chinese medicine. The paper introduces the records, development and applications of carbon medicine in ancient China. The earliest record found about carbon medicine was in the remains of Han dynasty (BC206-A.D.8). The paper also introduces the process of charring herbs and mechanism of carbon medicine in arresting bleeding. Calcium iron and tan released during the charring are believed as main factors for arresting bleeding, helped with porous surface structure of active carbon.

  • PDF

A Study on Electricity Properties of Polyethylene Terephthalate Film due to Thermally Degradation (열 열화에 의한 폴리에틸렌 테레프탈레이트 필름의 전기 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.11
    • /
    • pp.693-698
    • /
    • 2017
  • In this study, the thermal degradation properties of polyethylene terephthalate film has been examined by the capacitance, Tan ${\delta}$, thermography, FTIR, and SEM results at temperatures of $90{\sim}170^{\circ}C$ and frequencies of 0.3~3,000 kHz. It was found that the capacitance decreased with increasing thermal imaging temperature, probably caused by weakening of chemical bond with increasing temperature. Tan ${\delta}$ decreased upon increasing temperature from $90^{\circ}C$ to $170^{\circ}C$, probably due to the molecular motion of COOH radical or OH radical. The FT-IR measurement reveals that no structural change of the material occurs upon thermal radiation. The SEM measurement shows that the material is stabilized by thermal decomposition with increasing temperature; however, excessive thermal degradation obstructs the stabilization of the material.

Characteristics of Insulation Aging in Large Generator Stator Windings (대용량 발전기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1375-1379
    • /
    • 2009
  • Insulation tests have been performed on two generator stator bars under accelerated aging under a laboratory environment. Electrical stress was applied to stator bar No.1, and electrical and thermal stresses were applied to stator bar No.2. Nondestructive stator insulation tests including the ac current, dissipation factor($tan{\delta}$), and partial discharge tests have been performed on both bars as the bars were aged for 11460 hours. Experimental test results show that ${\Delta}I$, ${\Delta}tan{\delta}$, and partial discharge of No. 1 and No.2 stator bars increased with increased in aging time. It has been concluded from the test that the stator insulation of the two generators are in good condition.

A selection theorem and its application

  • Lee, Gue-Myung;Kim, Do-Sang;Lee, Byung-Soo;Cho, Sung-Jin
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.3
    • /
    • pp.759-766
    • /
    • 1995
  • In this paper, we give equivalent forms of the selection theorem of Ding-Kim-Tan. As applications of the selection theorem of Ding-Kim-Tan, we obtain a fixed point theroem of Gale and Mas-Colell type and establish an equilibrium existence theorem for a qualitative game under suitable assumptions in a locally convex Hausdorff topological vector space.

  • PDF

A Study on electrical Characteristics of XLPE by additives (첨가제에 의한 전력 cable용 XLPE의 전기적 특성에 관한 연구)

  • 김규식;손원근;임기조;박수길
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.61-64
    • /
    • 2000
  • Three kinds of treeing inhibitors are added to investigate the effect on electrical properties of XLPE. The treeing inhibitors are barbituric acid, 4- (4-Nitrophenylazo) resorcinol and 4- (4-Nitrophenylazo) naphthol. Added amount of each treeing inhibitors varied form 0phr to 2.0phr. In order to know the changes of electrical properties, break down strength, tan$\delta$, and $\varepsilon$$_{r}$ were measured. Experimental results showed that electrical properties of each sample was slightly changed by amount of additives.s.

  • PDF

The Effect of Pressurized Hydrogen on the Aging and Partial Discharge Activity in Generator Winding Insulations (가압 수소가 발전기 고정자 권선 절연 열화와 부분 방전 특성에 미치는 영향)

  • 김진봉
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.100-107
    • /
    • 1999
  • The purpose of the study is to investigate the effect of H$_2$ pressure on partial discharge (PD) activity and aging rate in turbine generator winding insulations. A series of field tests and laboratory tests were peformed to investigate the effect of $H_2$ pressure on PD activity. Field tests were conducted at two unit turbine generators in two conditions, in $H_2$ pressure and in air atmosphere. Obtained results are as follows ; 1) ${\Delta}tan{\delta}$ and maximum partial discharge are reduced with increase of $H_2$ pressure and partial discharge inception voltage. 2) The reduction ratio of ${\Delta}tan{\delta}$ due to $H_2$ pressure is higher than one of PD magnitude. 3) Partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. From the result, partial discharge pulses are subjected to resonance phenomena in a generator winding.

  • PDF

A Study on the Correlation between the Lapse of Time and Diagnostic Test Results of Large Rotating Machine Windings (대형 회전기의 절연진단결과와 경년 특성과의 상관관계에 관한 연구)

  • Kim, K.H.;Cho, Y.O.;Sun, J.H.;Kim, Y.B.;Ryu, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.966-968
    • /
    • 1992
  • We have done the insulation diagnostic test of generators in domestic five power plants since 1987 and tested A.C. current increasing rate($\Delta$I), $\Delta$tan$\delta$ and partial discharge in generator winding insulation. This study is described the correlation between nondestructive result(A.C. current increasing rate, $\Delta$tan$\delta$ and partial discharge) and lapse of time in generators.

  • PDF