• Title/Summary/Keyword: TA Program

Search Result 65, Processing Time 0.021 seconds

Electrochemical treatment of wastewater using boron doped diamond electrode by metal inter layer

  • KIM, Seohan;YOU, Miyoung;SONG, Pungkeun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.251-251
    • /
    • 2016
  • For several decades, industrial processes consume a huge amount of raw water for various objects that consequently results in the generation of large amounts of wastewater. Wastewaters are consisting of complex mixture of different inorganic and organic compounds and some of them can be toxic, hazardous and hard to degrade. These effluents are mainly treated by conventional technologies such are aerobic and anaerobic treatment and chemical coagulation. But, these processes are not suitable for eliminating all hazardous chemical compounds form wastewater and generate a large amount of toxic sludge. Therefore, other processes have been studied and applied together with these techniques to enhance purification results. These include photocatalysis, absorption, advanced oxidation processes, and ozonation, but also have their own drawbacks. In recent years, electrochemical techniques have received attention as wastewater treatment process that could be show higher purification results. Among them, boron doped diamond (BDD) attract attention as electrochemical electrode due to good chemical and electrochemical stability, long lifetime and wide potential window that necessary properties for anode electrode. So, there are many researches about high quality BDD on Nb, Ta, W and Si substrates, but, their application in effluents treatment is not suitable due to high cost of metal and low conductivity of Si. To solve these problems, Ti has been candidate as substrate in consideration of cost and property. But there are adhesion issues that must be overcome to apply Ti as BDD substrate. Al, Cu, Ti and Nb thin films were deposited on Ti substrate to improve adhesion between substrate and BDD thin film. In this paper, BDD films were deposited by hot filament chemical vapor deposition (HF-CVD) method. Prior to deposition, cleaning processes were conducted in acetone, ethanol, and isopropyl alcohol (IPA) using sonification machine for 7 min, respectively. And metal layer with the thickness of 200 nm were deposited by DC magnetron sputtering (DCMS). To analyze microstructure X-ray diffraction (XRD, Bruker gads) and field emission scanning electron microscopy (FE-SEM, Hitachi) were used. It is confirmed that metal layer was effective to adhesion property and improved electrode property. Electrochemical measurements were carried out in a three electrode electrochemical cell containing a 0.5 % H2SO4 in deionized water. As a result, it is confirmed that metal inter layer heavily effect on BDD property by improving adhesion property due to suppressing formation of titanium carbide.

  • PDF

Distribution of High Risk Human Papillomavirus Types in Western Kazakhstan - Retrospective Analysis of PCR Data

  • Bekmukhambetov, YZ;Balmagambetova, SK;Jarkenov, TA;Nurtayeva, SM;Mukashev, TZ;Koyshybaev, AK
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2667-2672
    • /
    • 2016
  • Background: Virtually all cases of cervical cancer are caused by persistent infections with a restricted set of human papillomaviruses (HPV). Cancer of the cervix is the third or even the second most common cancer in women worldwide, more than 85% of the cases occurring in developing countries, such as China and India, including the Republic of Kazakhstan. The purpose was to determine the HPV type distribution to evaluate efficacy of vaccination and adjust cancer prevention strategy in Western Kazakhstan in the future. Materials and Methods: A retrospective analysis was conducted of data obtained from PCR laboratories in 4 regional centers for the time period covering 12 months, 2013-2014, using AmpliSens$^{(R)}$ Real-Time PCR kits for HPV testing of 12 genotypes (16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, and 59). Results: A total of 1,661 persons were HPV tested within 2013-14, but a proprotion examined for 16 and 18 genotypes only (563) was not been included for statistic analysis of distribution and ratio of the most common genotypes. Males accounted for only a small number (N=90 in total). Conclusions: Total number of the HPV-positive appeared to be 26.0%, or 286 of N=1098. Types distribution was as follows: type 16 (10.7%), 39 (5.83%), 51 (5.27%), 31 (4.85%), 56 (4.58%), 18 (3.61%), 59 (2.64%), 58 (2.22%), 35 (1.94%), 33 (1.25%). Overall the HPV infection was highest in 16-29 years old (62.4%) and decreased with age. Total prevalence of the HR-HPVs amongst male population was 21.4% with top five types 16, 18, 39, 51, 31. Trends forcorrelations between Aktau site and type 33 (Cramer's V 0.2029), between Caucasian ethnicity and type 33 (Cramer's V .1716), and between European ethnicities in Uralsk and type 45 (Cramer's V .1752) were found. Of N 563 tested separately for 16 or 18 types, 13.6% were positive. As a whole, the distribution of 16/18 types had a ratio of 3.53:1. Given the vaccine-targeted type 16 is widely spread amongst this regional population, HPV immunization program of adolescent girls 10-13 years should be implemented appropriately.

DNA Damage by X-ray and Low Energy Electron Beam Irradiation (X선과 저에너지 전자선에 의한 DNA 손상)

  • Park, Yeun-Soo;Noh, Hyung-Ah;Cho, Hyuck;Dumont, Ariane;Ptasinska, Sylwia;Bass, Andrew D.;Sanche, Leon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • We observed DNA damages as a function of mean absorbed dose to identify the indirect effect of high-energy radiation such as x-ray. Monolayer films of lyophilized pGEM-3Zf(-) plasmid DNA deposited on tantalum foils were exposed to Al $K{\alpha}$ X-ray (1.5 keV) for 0, 3, 7 and 10 min, respectively, in a condition of ultrahigh vacuum state. We compared DNA damages by X-ray irradiation with those by 3 eV electron irradiation. X-ray photons produced low-energy electrons (mainly below 20 eV) from the tantalum foils and DNA damage was induced chiefly by these electrons. For electron beam irradiation, DNA damage was directly caused by 3 eV electrons. Irradiated DNA was analyzed by agarose gel electrophoresis and quantified by ImagaQuant program. The quantities of remained supercoiled DNA after irradiation were linearly decreased as a function of mean absorbed dose. On the other hand, the yields of nicked circular (single strand break, SSB) and interduplex crosslinked form 1 DNA were linearly increased as a function of mean absorbed dose. From this study, it was confirmed that DNA damage was also induced by low energy electrons ($0{\sim}10\;eV$) even below threshold energies for the ionization of DNA.

A STUDY OF THE INFLUENCE ON PHONATION WHEN MAXILLARY ANTERIOR TEETH ARE MISSING (상악 전치부 결손이 발음에 미치는 영향에 관한 연구)

  • Roh Chang-Sup;Choi Dae-Gyun;Woo Yi-Hyung;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.338-360
    • /
    • 1992
  • This study was performed to investigate the phonetic alterations with upper anterior teeth were missing. To compare the changes of the phonations, before and after insertion of the temporary prosthesis, six subjects who lost their upper anterior teeth were selected (2-male, 4-female). Tested sounds (/ga(가), na(나), da(다), ra(라), sa(사), ja(자), cha(차), ta(타), pa(파), ha(하), gi(기), ni(니), di(디), ri(리), si(시), jl(지), chi(치), ti(티), pi(피), hi(히), seu(스), se(세), so(소), su(수)/were programmed into an IBM AT with and without temporary prosthesis. These experiments were analyzed by formants, consonants durations, and energy level changes with an LSI speech work station program. During the pronunciation of the tested sounds (with and without temporary prosthesis), mandibular movements were recorded to a Mandibular Kinesiogram and analyzed . The findings led to the following conclusions: 1. Objective differences could not be found. However, in every informant, subjective improvement could be noticed. 2. There were no persistant correlations of the formant's changes. And in every informant, phonetic changes were variable. 3. There were various changes of the consonant durations in every informant. By and large, those of /si(시), jl(지), chi(치), Pi(피), hi(히)/ were longer than other tested sounds. After insertion of the prosthesis, durations were shorter. Consonants with /i(ㅣ)/ were longer than with /a(ㅏ)/, with or without prosthesis. 4. With and without temporary prosthesis, mandibular movements were various in the frontal view. Mandibular movements showed lateral deviations, and mandibular positions with /si(시), ji(지), ti(티), seu(스), hi(히)/ were nearer to the mandibular rest position. 5. The kinds of temporary prosthesis and conditions of the missing teeth influenced every informant variously, so there were no correlation between informants. 6. Energy levels increased in all tested sounds with a fixed temporary prosthesis. And, there were no differences between before and after insertion of a removable temporary prosthesis. However, sibilant sounds, and consonants with /i(ㅣ)/ showed a little increased energy level.

  • PDF

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.