• Title/Summary/Keyword: T3SS

Search Result 548, Processing Time 0.028 seconds

Adhesion Characteristics of Polymers and Ceramic Surface Coated on Metal by Plasma Spray (플라즈마 용사법에 의한 금속면에 세라믹 코팅된 표면과 범용고분자와의 접착특성)

  • Lee, Gyeong-Hui;Gwon, Sun-Hun;Jo, Won-Je;Ha, Chang-Sik
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.724-734
    • /
    • 1999
  • The adhesion characteristics of the thermoplastic resins such as PE, PP PVC, PET and PS were investigated on the surfaces of conventional steel (SS41), steel (SS41P) treated with ultrasonic waves and the SS41P coated with several ceramic powders (SS41PC) by the plasma spray. Alumina (Al$_2$O$_3$), alumina titania (Al$_2$O$_3$95%, TiO$_2$ 5%) and zirconia yttria (ZrO$_2$ 95%, $Y_2$O$_3$5% ) were used for the materials plasma spray The morphologies, surface hardness, surface roughness, and contact angles on SS41, SS41P, and SS41PC were examined. The tensile shear strength and peel strength of the polymers which were attached to the surfaces of ceramics coated on SS41P also were measured. The tensile shear strength and peel strength of polymers adhered to ceramic surface coated on steel were found to be stronger than those of conventional steel. The tensile shear strength and peel strength of the polymers adhered on the surfaces of ceramics coated steel increased in the following order PE > PET > PP > PS > PVC. The high adhesion strength of PE may be attributed to the surface roughness and its anchor effect on the ceramic surface.

  • PDF

Study on Pollutant Characteristics of Tunnel Cleaning Wastewater and Removal Characteristics of the Pollutants via Settling and Adsorption (터널 세척 폐수 특성 및 분리.흡착 방식에 따른 오염물질 저감 연구)

  • Park, Sang-Woo;Choi, Young-Hwa;Oh, Je-Ill
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • Washed wastewater generated from the intermittent cleaning process of the three tunnel sites located in the Seoul area showed high concentrations of SS, $COD_{Cr}$, T-N, $NH_3-N$, $NO_3-N$, Zn, Cu, Cr(+6), Mn, Mg, Phenol, $CN^-$ and E-Coli based on the water quality analysis. These characteristics of the deteriorative wastewater depend on the sampling method, cleaning frequency, released amount of washing water, inner material of tunnel wall, traffic volume, and type of drainage systems. Gravitational separation experiment of SS with collected tunnel wastewater showed considerable removal of pollutants such as 80% of $COD_{Cr}$, 30% of T-N and 90% of T-P simultaneously. GAC isotherm test was conducted to remove dissolved portion of the pollutants, and resulted in high removal efficiencies above 80% of $COD_{Cr}$, T-N, Zn, Cu, Mn, Phenol, CN in the experimental condition of GAC dosage of $50g/1/{\ell}$.

  • PDF

A Study on the Optimal Operating Conditions for Removal of Nutrient Influential Substances Using Functional Media (기능성 여재를 활용한 부영양화 영양물질 제거의 최적 운전조건 연구)

  • Lee, Jong-Jun;Oh, Jong-Min;Choi, Seung-Jong;Kim, Ki-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.549-555
    • /
    • 2019
  • The purpose of this study is to ensure optimal operating conditions for improving the removal efficiency of phosphorus (P) and nitrogen (N) that are the causative agents of eutrophication by utilizing functional media. The main ingredients of the functional media used in this study are Si, Al, and Fe, SiO2, KAlSiO3O8, Al2O2·2SiO2O, H3Al2Si2O9, Fe3O4O), and berylite. To identify the maximum efficiency of the filtration process, the processing efficiency experiment was carried out according to flow method, velocity, and thickness of residual media. The flow method carried out two experiments, 50 m/day, 100 m/day, 150 m/day, 200 m/day, 250 m/day, and 20 cm, 40 cm, 50 cm, 60 cm, 80 cm of lead depth. Experiments have shown that SS, T-N, and T-P all showed higher elimination efficiency of the upflow current conditions than the downflow current conditions, and that the processing efficiency of the linearity is the highest at SS 50 m/day, T-N 150 m/day and T-P 100 m/day. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. It is considered desirable to set the top-down flow conditions and residual thickness of 60 cm and adjust the velocity of the line according to the target media for removal.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

Upregulaton of Bradykinin Receptor Mediated by Nucleoside Diphosphate Kinase and Flagellin from Pseudomonas aeruginosa (Bradykinin Receptor의 발현에 미치는 녹농균유래 Nucleoside Diphosphate Kinase 및 Flagellin의 효과)

  • Kim, Yong-Jae;Shin, Hee-Sung;Jin, Shouguang;Ha, Un-Hwan
    • Korean Journal of Microbiology
    • /
    • v.50 no.4
    • /
    • pp.281-284
    • /
    • 2014
  • Immune defense responses against Pseudomonas aeruginosa infection play an important role in maintaining homeostasis in the human body. Previously, we reported that expression of the bradykinin receptor (BR) is induced in response to P. aeruginosa infection. However, the factors responsible for the induction was uncertain. Here, we found that the type III secretion system (T3SS) is responsible for the induction of BR expression, and nucleoside diphosphate kinase (Ndk), as a novel T3SS effector, mediates the upregulation. The Ndk-mediated expression of BR was not induced by fliC mutant treatment, indicating the involvement of flagellin, one of the well-known pathogen-associated molecular patterns (PAMPs). Taken together, this study demonstrated that Ndk cooperates with flagella in the development of defense responses against P. aeruginosa infection.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

Review of 5-year Experimental Data from Treatment Wetland (인공습지 실험시설의 5년간 결과 및 고찰(지역환경 \circled3))

  • 김민희;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.649-654
    • /
    • 2000
  • Field experiment was performed from August 1996 to June 2000. The pilot plant was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand and reed. Average removal rate of BOD, SS was about 75.9%, 73.4%, respectively. T-P removal rate was about 47.3%, and T-N removal rate was 19.6%. The reason for poor T-N removal might be due to high influent concentration and short retention times. As operation period increased, BOD removal rates were increased, and SS and T-P removal rates did not change significantly, but T-N removal rates were decreased.

  • PDF

Effect of Microbubble Ozonation Process on Performance of Biological Reactor System for Excess Sludge Solubilisation (마이크로버블오존을 이용한 잉여슬러지 가용화 처리가 생물반응조의 성능에 미치는 영향)

  • Lee, Shun-Hwa;Jung, Kye-Ju;Kwon, Jin-Ha;Lee, Se-Han
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • The study purpose was to examine an effect of zero emission of excess sludge on biological reactor and treated water quality within the biological reactor in the process of biological treatment combined with excess sludge reduction system with ozone. Under an ozone injection rate 0.03 g $O_3/g$ SS, Sludge Disintegration Number (SDN) 3 and less than pH 4 as pre-treatment process, it was possible to maintain a stable biological treatment process without sludge disintegration. In the test of $OUR_{max}$, of sludge, its value was hardly under the condition of ozone injection rate 0.03 g $O_3/g$ SS. There were almost no changes of MLVSS/MLSS within biological reactor followed by a solubilization of excess sludge. Accumulation of microorganism within biological reactor was also not observed. After solubilization of excess sludge, an increase for organic matter and SS concentrations of an effluent was not observed and T-N concentration was reduced by increasing nitrification and denitrification rate within biological reactor. Most of T-P was not removed by zero emission of excess sludge and was leaked by being included in effluents.

Treatment Efficiencies and Decomposition Velocities of Pollutants in Constructed Wetlands for Treating Hydroponic Wastewater (인공습지시스템을 이용한 폐양액처리장에서 오염물질의 정화효율 및 오염물질 분해속도)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Choong-Heon;Lee, Seong-Tea;Jeong, Tae-Uk;Lee, Sang-Won;Ha, Yeong-Rae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.937-943
    • /
    • 2011
  • In order to develop constructed wetlands for treating hydroponic wastewater in greenhouses, removal efficiencies and decomposition velocities of pollutants in constructed wetland were investigated for treating hydroponic wastewater. Removal rates of BOD, COD, SS, T-N and T-P in effluent in constructed wetlands were 88%, 79%, 92%, 64% and 92%, respectively. The decomposition velocities (K; $day^{-1}$) of pollutants in $1^{st}$ HF bed of constructed wetlands were higher in the order of SS ($0.54day^{-1}$) > BOD ($0.39day^{-1}$) > COD ($0.27day^{-1}$) > T-P ($0.26day^{-1}$) > T-N ($0.06day^{-1}$). In $1^{st}$ HF bed of constructed wetlands, the decomposition velocity of SS was rapid than that for BOD, COD, T-N and T-P in constructed wetland for treating hydroponic wastewater. The decomposition velocity (K; $day^{-1}$) of pollutants in $2^{nd}$ HF bed of constructed wetland were higher in the order of T-P ($0.52day^{-1}$) > BOD ($0.28day^{-1}$) > COD ($0.15day^{-1}$) > T-N ($0.06day^{-1}$) > SS ($0.10day^{-1}$). In $2^{nd}$ HF bed of constructed wetlands, the decomposition velocity of T-P was rapid than that for BOD, COD, SS and T-N in constructed wetland for treating hydroponic wastewater.

Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces (수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가)

  • Kim, Bong Kyun;Seo, Dae Seuk;Oh, Jong Min;Park, Jae-Ro
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.238-246
    • /
    • 2016
  • Water purification facilities utilizing three technologies - a detention pond, an artificial wetland and an ecological revetment - were installed in waterfront spaces, including river embankments and watersides that have so far been left neglected, and then their water purification levels were analyzed in this study. The water purification facilities were found to show average removal efficiencies of 48.6% in suspended solid (SS), 30.5% in biochemical oxygen demand (BOD), 18.4% in total nitrogen (T-N) and 27.3% in total phosphorus (T-P) during rainfall. The removal efficiencies during non-rainfall were 33.2% in SS, 28.6% in BOD, 13.7% in T-N and 17.3% in T-P. These results showed that the water purification facilities using a detention pond, an artificial wetland and an ecological revetment can be used as a useful natural water purification technology in in waterfront spaces.