• Title/Summary/Keyword: T3SS

Search Result 548, Processing Time 0.02 seconds

Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data (2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석)

  • Son, Younggyu;Na, Seungmin;Im, Tae Hyo;Kim, Sang-hun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

The Development on Train Detection System and Performance Testing on Automatic Changeover System in Neutral Section (절연구간 자동통과 열차검지시스템 개발 및 성능시험)

  • Han, M.S.;Chang, S.H.;Shin, M.C.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.431-436
    • /
    • 2013
  • A neutral section is installed around feeding substation(SS) and sectioning post(SP) that M phase and T phase are isolated in AC feeding system. Electric Train under "Notch-OFF" is operated by inertia within the neutral section. It causes disturbing the operation of electric trains for speed drop and driver's mistakes. A automatic changeover system with thyristor recently have taken under development. In the paper, it is introduced the configuration of train detection system and performance testing on automatic changeover system..

Evaluation of Newly Developed Chemical Castration Method: Changes in Hormone Gene Expression of Hypothalamic-Pituitary Axis

  • Kwak, Byung Kuk;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.21 no.3
    • /
    • pp.307-315
    • /
    • 2017
  • Surgical castration (also known as orchidectomy, ORX) has been frequently performed to avoid uncontrolled breeding. However, it has some serious disadvantages. Several laboratories have developed chemical castration methods, using bilateral intratesticular injection (BITI) of simple chemical solutions. The present study was undertaken to compare the effects of ORX and of hypertonic saline BITI on the androgen-sensitive tissues such as pituitary and hypothalamus. Serum testosterone (T) levels of ORX animals and hypertonic saline BITI animals (SAL) after 4 weeks of the manipulations exhibited significantly drops as compared with the levels of intact animals ( $Intact:ORX:SAL=7.74{\pm}1.31:1.34{\pm}0.19:1.28{\pm}0.18ng/ml$, p<0.001). Both ORX and BITI method induced similar stimulatory effects on the pituitary gonadotropin subunits and hypothalamic KiSS-1 gene expressions. In contrast, the effects of ORX and hypertonic saline BITI on hypothalamic GnRH gene expression were different from these gene expressions, shown an inverse relationship between the two groups ($Intact:ORX:SAL=1:0.45{\pm}0.06:1:2.07{\pm}0.41:1.51{\pm}0.37AU$; ORX, p<0.001; SAL, p<0.05). In conclusion, we provided evidence that hypertonic saline BITI method has equivalent efficacy of T depletion to surgical castration in rats. The present study suggests the hypertonic saline BITI could be a promising substitute to conventional surgical castration.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

Strength and Water Purification Characteristics of Effective Microorganism-applied Volcanic Ash Block (유용미생물을 적용한 화산재 블록의 강도 및 수질정화 특성)

  • Lee, Chung-Won;Chang, Dong-Su;Park, Sung-Yong;Choi, Joong-Dae;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The aim of this study is to investigate strength and water purification characteristics of effective microorganism-applied volcanic ash block using flexural strength test and water quality analysis. The specimens were prepared with volcanic ash from Mt. Baekdusan and Mt. Hallasan, and cement as the ratios of 3.5:1, 4.0:1, 4.5:1, 5.0:1 with and without metakaolin. Flexural strength degraded with increasing of the amount of volcanic ash, and increased with addition of metakaolin as a binder. Based on these results, the optimal ratio for fabricating volcanic ash-cement mixture block is determined as 3.5:1 with metakaolin. Furthermore, from water quality analysis on contaminated water, removal ability of effective microorganism-applied volcanic ash-cement mixture block and caged volcanic ash block against T-N, T-P and SS was highly evaluated because of adsorption due to the large specific surface area of volcanic ash. Hence, volcanic ash-cement mixture block and caged volcanic ash block possibly contribute to water purification.

A Study on the Foam Wastewater Treatment and Foam Collection by Inhalation Force at the Outlet of Power Plants (발전소 방류구의 흡입력을 이용한 거품수거 및 거품액 처리 연구)

  • Jang, Heui-Su;Mun, Gyeng-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.496-499
    • /
    • 2005
  • Power Plant is requested, by environmental bodies and fisherman, to correct the pollution of coastal area due to the outflow of foam from the outlet of the power plants. Foam wastewater cause a lot of environmental problems, expecially in aesthetic points of view. Therefore, It is needed to be collect from the stream into nearby ocean, and the collected foams should be treated before being discharged into nearby ocean. The most effective and feasible treatment method researched for the effective treatment of foam wastewater generated at the power plants. The result of the test is confirmed with collecting Foam wastewater by inhalation force. The treatment pilot ($3m^3/hr$) collected wastewater was operated by Biological degradation method(Aerobic/anaerobic Processes) for approximately two months. It was removed SS, COD, nutrient(T-P, T-N), etc. The System is expected successfully by Minimizing the operating costs such as electricity, repair expenses, chemicals and supplies expenses.

Development and Application of Modified Intermittently Aeration mode for Advanced Phase Isolation Ditch (APID) process at Winter Season (APID공정 내 동절기 개량형 간헐포기 운전모드 적용 및 개발)

  • Kwak, Sung-Keun;An, Sang-Woo;Chung, Mu-Keun;Park, Jae-Ro;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.872-878
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to develop and apply the modified intermittently aeration mode as process control conditions for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 6.3, 4.5, 10.0, and 1.3 mg/L. The modified mode decreased the nitrification capability more than the conventional mode in the application period. Nitrate in the anaerobic condition can have a negative effect on biological phosphorus removal. In the decreasing nitrate levels, the modified mode increased the biological ability of removal phosphorus more than the conventional mode in this study. Therefore, newly developed APID process with modified intermittent aeration mode can be one of the useful processes for stable organic matter and nutrients removal.

Evaluation of NPS Pollutant Loads from Clayey Loam Fields (점토질 롬 밭과 논의 비점오염원 부하량 평가)

  • Choi, Joong-Dae;Kwun, Soon-Kuk;Kwon, Gi-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.107-114
    • /
    • 2004
  • NPS pollutant loads from sandy clayey and clayey loam runoff plots were measured. Runoff plots were 2$\times$10 m in size and 8~10% in slope and paddy area was 4,620 $m^2$. Soybean, corn, tobacco and control (natural weed) were cultured. Precipitation during the growing season of June to October, 2002 was 869.5 mm. Runoff and water quality were measured more than 10 times during the measurements depending on the growing stage. Pollutants loads were estimated by using respective concentration and runoff volume. Runoff occurred when daily rainfall exceeded about 30 mm. The largest runoff was observed from the paddy but pollutant loads were larger from upland crops than those from paddy. SS loads from paddy and upland were 1.4 ton/ha/yr and 3.1~4.3 ton/ha/yr, respectively. COD loads 30 kg/ha/yr and 66~90 kg/ha/yr, T-N loads 13 kg/ha/yr and 14~23 kg/ha/yr, T-P loads 1 kg/ha/yr와 4 kg/ha/yr, nitrate nitrogen loads 1 kg/ha/yr and 4~8 kg/ha/yr, and phosphate phosphorus loads 0 kg/ha/yr and 4~6 kg/ha/yr, respectively. It was concluded that NPS pollutant loads from upland crop culture have greater impact on the quality of the receiving water body than those from paddy culture.

Characteristics of Non-Point Pollutants Discharge in a Small Rural Watershed (농촌 소유역에서의 비점오염물질 유출 특성 - 충남 공주시 정안면 고성리 지역을 대상으로 -)

  • Kim, Jin-Ho;Han, Kuk-Heon;Ryu, Jong-Su;Lim, Hyuk-Jin;Lee, Kyung-Do;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.552-556
    • /
    • 2005
  • This study was conducted to identify the characteristics of non-point pollutants discharge in a small Rural watershed. For this purpose, the typical rural area in Gongju city was selected as a research site. Water quality and water quantity data in the stream and the precipitation of the watershed were analyzed periodically from May 1 to August 31 in 2005. Also, pollutant loads were estimated using these data. As a result, the mean concentrations of BOD, TN and TP in the stream were 3.16, 3.20, 0.236 mg/L rainy season and 0.93, 2.75, 0.058 mg/L in normal survey season respectively. The estimation of non-point pollutants discharge loads were shown that BOD was 5,154.2kg, T-N was 9,164.7kg, T-P was 308.4kg, and SS was 117,163.2kg from July to August. That means above of 90% of non-point pollutants discharge was occurred in rainy season.

  • PDF

Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation) (DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구)

  • Lee., Byoung-Ho;Kim, Sung-Hyuk;Lee, Sang-Bae;Kim, Mi-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.