• 제목/요약/키워드: T2-Fat Saturation

검색결과 11건 처리시간 0.028초

Magnetic Resonance Imaging Evaluation of the Prostate in Normal Dogs

  • Cho, Yu-Gyeong;Choi, Ho-jung;Lee, Ki-ja;Lee, Youngwon
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.317-323
    • /
    • 2020
  • The aims of this study were to describe the appearance and size of the normal canine prostate using magnetic resonance (MR) imaging and to calculate the apparent diffusion coefficient (ADC) values. MR images were obtained from seven intact male beagle dogs using a 1.5 T MR unit. The sequences included pre- and post-contrast T1- and T2-weighted imaging with and without fat saturation. The signal intensity of the prostate was compared with the adjacent musculature, fat, and urine in the urinary bladder. We recorded the mean prostatic length, width, and height and the length of the sixth lumbar vertebral body (L6). In addition, the prostatic length (rL), width (rW), and height (rH) ratios to L6 were calculated. Diffusion-weighted images of the prostate were obtained and ADC values were calculated. The prostate was bilobed and oval-shaped, homogenous on T1-weighted images, and heterogeneous with radiating lines on T2-weighted images. Post-contrast T1-weighted sequences showed contrast enhancement of the central and radiating striations. The prostatic capsule was clearly identified on post-contrast T1-weighted images with fat saturation. The ADC values were 1.72-2.04 × 10-3mm2/sec (mean, 1.88 × 10-3mm2/sec). Knowledge of the normal appearance of the prostate on MR images is essential to assess prostatic diseases in dogs.

상완신경총 환자에서 최적의 자기공명영상 지방소거 기법에 관한 연구 : SPAIR, STIR 지방소거 중심으로 (A Study on Optimized MRI Fat-Saturation Technique for Brachial Plexus Patients : Focused on SPAIR and STIR Fat-Saturation)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제8권5호
    • /
    • pp.271-278
    • /
    • 2014
  • 상완신경총에서 STIR(short TI inversion recovery) 지방소거 강조영상과 SPAIR(spectral adiabatic inversion recovery) T2, T1 지방소거 강조영상기법을 비교 평가하여 최적의 지방소거 기법을 알아보고자 하였다. 총 30 명 상완신경총에 질환이 없는 정상인 지원자를 대상으로 3.0 T MRI 기기를 이용하여 검사를 하였고, 분석방법으로 세 기법에 대하여 SNR, CNR 및 4단계 점수로 평가를 하였다. 정량적 분석 결과로 SPAIR T1 기법에 대한 SNR, CNR 값은 상완신경총기시부($03.07{\pm}0.98$, $-2.25{\pm}0.54$), 상완신경총몸체($06.70{\pm}1.81$, $36.31{\pm}2.17$)에서 높은 값을 제공하였다 (p<0.05). 정성적 분석결과 상완신경총 묘출도와 지방소거 정도, 영상의 인공물은 SPAIR T1($3.2{\pm}0.70$, $3.6{\pm}0.51$, $3.4{\pm}0.10$)기법이 의미 있게 높게 나타났다(p<0.05).

화학적 포화 호흡정지 급속 자기공명영상에서 국소적 간지방병변의 특성화 (Chemical Saturation Breath-hold Fast MR Imaging for characterization of Regional Fatty Changes in Liver)

  • 김동국;유정식;김태훈;오세정;김지형
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.135-141
    • /
    • 1997
  • 목적: 초음파에서 의심된 국소적 간지방병변을 진단함에 있어 화학적 포화 방식의 지방억제를 호함한 호흡정지 급속 자기공명영상의 유용성을 알아보기 위함이다. 대상 및 방법: 초음파검사에서 발견된 국소 간병변의 진단을 위해 자기공명영상을 촬영할 때 별도의 parameter 조정없이 지방억제 전후의 영상을 얻을 수 있는 화학적 포화방식의 영상을 추가하였을 때 국소병변의 전체에 걸쳐 균일한 신호가도의 변화가 있었던 환자 13명을 대상으로 하였다. 지방억제 전후의 영상을 fast low-angle shot(FLASH) sequence를 이용한 T1강조영상과 turbo spin-echo sequence를 이용한 T2강조영상으로 호흡정지증의 급속영상을 얻었으며 각각의 병변에 대해 지방억제 전후 의 T1강조영상과 T2강조영상에서 주변 간실질에 대해 상대적인 신호강도의 증감과 초음파 소견상의 에코의 증감을 비교하였다. 결과: T1이나 T2강조영상에서 신호강도가 지방억제 후 감소했던 환자는 7명이었으며 이 중 3명은 지방억제 후의 T1강조영상에서만 신호강도가 감소하였으며 7명 모두 초음파상 고에코의 국소병변과 일치하여 국소지방침착 소견과 일치하였다. 지방억제 후 T2강조영상에서만 주변 간실질에 비해 신호강도가 높았던 2명을 포함하여 지방억제 후 T1과 T2강조영상에서 신호강도가 상대적으로 높아 보였던 6명은 모두 초음파에서 저에코의 병변을 가지고 있어서 국소지방결여와 잘 일치하였다. 국소지방침착의 경우 지방억제 후 T1강조영상의 신호강도의 감소가 T2강조영상에서의 변화에 비해 컸으며(P=0.0002) 국소지방결여의 경우는 T2강조영상에서의 변화가 T1강조영상에 비해 상대적으로 현저하였다(P=0.042). 결론: 호흡정지 급속영상방법의 T1과 T2강조영상에서 공히 화학적 포화방식을 이용한 지방억제 전후의 영상을 얻으면 초음파에서 발견된 국소병변을 간지방변화로 특성화하기에 충분할 것이다.

  • PDF

Improvement of Fat Suppression and Artifact Reduction Using IDEAL Technique in Head and Neck MRI at 3T

  • Hong, Jin Ho;Lee, Ha Young;Kang, Young Hye;Lim, Myung Kwan;Kim, Yeo Ju;Cho, Soon Gu;Kim, Mi Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2016
  • Purpose: To quantitatively and qualitatively compare fat-suppressed MRI quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency selective fat-suppression (FSFS) T2- and postcontrast T1-weighted fast spin-echo images of the head and neck at 3T. Materials and Methods: The study was approved by our Institutional Review Board. Prospective MR image analysis was performed in 36 individuals at a single-center. Axial fat suppressed T2- and postcontrast T1-weighted images with IDEAL and FSFS were compared. Visual assessment was performed by two independent readers with respect to; 1) metallic artifacts around oral cavity, 2) susceptibility artifacts around upper airway, paranasal sinus, and head-neck junction, 3) homogeneity of fat suppression, 4) image sharpness, 5) tissue contrast of pathologies and lymph nodes. The signal-to-noise ratios (SNR) for each image sequence were assessed. Results: Both IDEAL fat suppressed T2- and T1-weighted images significantly reduced artifacts around airway, paranasal sinus, and head-neck junction, and significantly improved homogeneous fat suppression in compared to those using FSFS (P < 0.05 for all). IDEAL significantly decreased artifacts around oral cavity on T2-weighted images (P < 0.05, respectively) and improved sharpness, lesion-to-tissue, and lymph node-to-tissue contrast on T1-weighted images (P < 0.05 for all). The mean SNRs were significantly improved on both T1- and T2-weighted IDEAL images (P < 0.05 for all). Conclusion: IDEAL technique improves image quality in the head and neck by reducing artifacts with homogeneous fat suppression, while maintaining a high SNR.

요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구 (Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane)

  • 정다빈;이해각;허영철
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.927-933
    • /
    • 2021
  • 본 연구에서는 mDixon 기법과 T2 TSE, T2 SPIR 기법을 비교하여 3번 허리뼈 체부, 등 지방, 척수, 뇌척수액 위치에서 검사 시간, 신호대잡음비, 대조도대잡음비의 차이를 알아보고자 하였다. 성인 30명을 대상으로 신호대잡음비에 영향 인자를 고정하고 요추 시상면을 mDixon검사와 T2 TSE, T2 SPIR 검사를 한 후 비교하였다. mDixon의 검사 시간은 115초, T2 TSE는 60초, T2 SPIR는 60초였다. mDixon T2영상은 T2 TSE 영상보다 3번 허리뼈 체부에서 신호대잡음비가 높았고, 등 지방과 뇌척수액에서는 SNR이 낮았으며(p<0.05), 척수에서는 비슷한 신호대잡음비을 가졌다(p>0.05). 3번 허리뼈 체부와 등 지방의 대조도대잡음비는 mDixon T2영상이 높았으며, 뇌척수액과 척수의 대조도대잡음비는 T2 TSE가 높았다(p<0.05). mDixon T2 FS영상은 T2 SPIR영상보다 3번 허리뼈 체부, 등 지방에서 낮았고, 척수, 뇌척수액에서는 높았다(p<0.05). 3번 허리뼈 체부와 등 지방의 대조도대잡음비는 mDixon T2 FS영상이 높았으며(p<0.05), 뇌척수액과 척수의 대조도 대잡음비는 두 영상이 차이가 없었다(p>0.05). mDixon 기법이 기존의 T2 TSE, T2 SPIR 기법에 비해 검사 시간, 각 부위의 신호대잡음비, 대조도대잡음비에서 보다 우수한 영상이라 하기 어려웠다. 하지만 본 연구는 단순 요추통증환자를 대상으로 제한하였다는 한계로, 기존의 연구에서 보고된 금속물 삽입, 척추 종양, 골절 환자 등 특정 환자군의 설정을 통한 추가 연구들이 필요할 것으로 사료된다.

Intramedullary Spinal Cord Lipoma Extending from the Cervicomedullary Junction to the Upper Thoracic Cord

  • Lee, Deok-Gu;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권1호
    • /
    • pp.71-73
    • /
    • 2005
  • A case of intramedullary spinal cord lipoma is presented. A one month-old male infant presented with irritability and weakness on his upper extremities. A magnetic resonance[MR] image of the cervical spine demonstrated a well defined, high signal intensity lesion on both T1 and T2-weighted MR images and suppression on the fat saturation sequence. The tumor mass extended from the foramen magnum to T2 vertebra level. Ventral displacement of the spinal cord with kinking of the cervico-medullary junction was evident on the T2-weighted sagittal image. Partial resection of the tumor mass through laminoplastic laminotomy from C1 to T2 resulted in improved motor weakness on his upper extremities.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법 (Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder)

  • 윤문현;성미숙;인창식;이흥규;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.98-107
    • /
    • 2006
  • 자화전이영상 (MTI)은 무릎의 연골조직, 활액, 연대 등에 있는 거대분자에 붙어 분자운동에 제한을 받은 수소와 비교적 자유로운 물 분자의 수소가 두 가지 자화 상태로 서로 교환되고 있는 상태에서 한쪽 자화상태를 RF 펄스를 사용하여 포화시키면 다른 자화 상태가 교환 상황에 따라 그 신호강도가 달라지면서 영상의 대조도를 이룬다. 교차이완은 수소의 T2 이완시간이 다르면서 생기는 두 스핀 풀로 모델화하여 물 분자와 거대분자 사이의 쌍극자들의 상호교환 뿐만 아니라 물분자와 거대분자의 수소 화학교환으로 설명된다. 이에 의학영상에서 가장 필수적 요소인 신호강도와 대조도를 조절하는 능력으로서 양성자 밀도와 T2 강조 무릎영상을 획득하여 비정상적 조직과 그 변화 위에 시퀀스와 더불어 무릎 조인트의 중간신호들에 의해 무릎 연골주위의 다른 조직과의 신호강도 차이를 더욱 높이기도 한다. 또한 지방억제 기술은 조직 대조도를 증대시키고 화학전이 인공물을 제거할 뿐 아니라 움직임과 관련한 고스트 인공물을 감소시킨다. 이와 같은 지방 포화억제는 위상감각 방법 (Phase Sensitive Method)에서 물과 지방의 세차운동 주파수에 차이를 나타낸다. 본 연구에서 위상감각 방법은 Larmor 주파수 차이를 직접 사용하기 보다는 그 주파수 차이결과를 축적하여 생기는 위상 차이를 보고자 하였다. 자화전이영상이 어떻게 작동하는가는 무릎조직의 자화전이(MT)에 대한 정량적 모델로 유도되는 임상적 증거에서 주어지지만 그 자화전이 효과를 설명하는 수학적 공식화는 전방 십자형 인대 (Anterior Cruciate Ligament)파열과 관절간연골 파열과 같은 무릎관절질환을 평가하는 데 적용하였고, 자화전이 포화 효과의 계산은 MT 펄스에 의한 신호강도에 상대적 감소를 정량적으로 측정하는 자화전이률에 의해 주어졌다.糖) 및 이성화당(異性化糖)의 개발생산(開發生産)이 시급(時急)하며 이런 감미원(甘味源) 생산공장(生産工場)의 대규모화(大規模化)로 경제적(經濟的) 양산(量産)을 서둘러야 될 줄 생각(生覺)한다. 우선적(優先的)으로 소요(所要)의 효소생산(酵素生産)에 대(對)한 개발연구(開發硏究)가 앞서야 하며, 이어서 전분(澱粉)으로부터 이성화당(異性化糖)에 이르기까지 단계적(段階的) 효소처리공정(酵素處理工程)의 확립(確立)과 새로운 공정(工程)의 개발연구(開發硏究)가 이루어져야 하겠다. 나아가서 보다 더 경제적(經濟的) 감미료(甘味料)의 생산(生産)과 생산공정(生産工程)의 능율화(能率化)를 위(爲)하여 전분당화(澱粉糖化) 및 이성화(異性化) 공정(工程)의 연속화(連續化)가 필연적(必然的)이며, 이에 소요(所要) 및 불용성(不溶性) 효소(酵素)의 생산공정(生産工程)도 연구(硏究)되어야 한다.>$16.8{\sim}30.1$ kcal/mole의 범위 안에 있으며 ginsenoside-Re 및 $-Rg_1$$ginsenoside-Rb_1,\;-Rb_2$, -Rc 및 -Rd 보다 훨씬 높으므로 troil saponin이 diol saponin보다 온도(溫度)의 영향(影響)을 더 많이 받고 있었다. 마. total ginsenosides의 분해반응시(分解反應時)의 활성화(活性化)에너지($E_a$)는 17.7kcal/mole이었고 분해속도상수(分解速度常數)의 온도의존성(溫度依存性)은 $k=4.574{\times}10^8{\exp}(-8898.8/T)$의 관계식(關係式)으로 표시(表示)할 수 있다rc}C,\;30^{\circ}C,\;45^{\circ}C$ 별로 각 fine spirit에 oak chip을 넣고 숙성시킨

  • PDF

연조직종양의 조직 성분 평가를 위한 자기공명영상: MEDIC 과 지방억제 T2 영상의 비교 (MRI Evaluation for the Histologic Components of Soft-tissue Tumors: Comparison of MEDIC and Fast SE T2-weighted Imaging)

  • 문태용;이인숙;이준우;최경운;김정일;김의신
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2008
  • 목적: 연조직종양의 조직 성분을 자기공명영상으로 평가하는데 MEDIC과 지방억제 T2 영상을 비교하여 더 나은 검사방법을 선택하고자 하였다. 대상 및 방법: 병리조직학적으로 진단된 연조직종양 10예 (신경집종 3예, 혈관종 2예, 지방종 1예, 혈관각화종 1예, 윤활막육종 1예, 지방육종 1예 그리고 악성섬유조직구종 1예)에서 25 조직 성분 (혈관 5예, 신경 4예, 섬유성 4예, 과세포성 4예, 출혈성괴사 2예, 낭성 2예, 지방성 2예, 점액버팀질 1예, 그리고 혈전 1예)을 선택하였다. 병리조직학적 조직 성분과 일치하는 동일 단면상을 가진 MEDIC과 지방억제 T2영상에 동일한 크기의 관심영역을 그려 불균질치를 얻었다. 불균질치는 영상의 불균질성을 나타내는 표준편차 값을 관심영역에서 얻은 신호강도 평균값으로 나눈 값으로 하였다. 결과: 25 조직 성분의 불균질치는 MEDIC 보다 지방억제 T2영상에서 높게 나타났다 (p < .001). 결론: MEDIC 영상은 불균질치가 현저히 낮으므로, 자기공명영상으로 연조직종양의 조직 성분을 평가하는데 지방억제 T2영상 보다 MEDIC 영상이 더 유용할 것으로 사료된다.

  • PDF

1.0Tesla 자기공명 영상장치에서의 분광영상기법에 관한 연구 (Spectroscopic Imaging at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.517-527
    • /
    • 1997
  • Magnetic Resonance Spectroscopic Imaging is a methodology combining the imaging and spectroscopy. It can provide the spectrum of each areas of image so that one can easily compare the spectrum of one position to another position of the image. In this study, we developed pulse sequence or the spectroscopic imaging method, RF wave forms or the saturation of water signal, computer simulations to validate our method, and confirmed the methodology with phantom experiment. Then we applied the spectroscopic method to human subject and identified a few important metabolites in in vivo. To develope a water saturating RF waveform, we used Shinnar-Le-Roux algorithm and obtained maximum phase RF waveform. With this RF pulse, it could suppress the water signal to 1:1000. The magnet is shimmed to under 1.0ppm with auto-shimming technique. The saturation bandwidth is 80Hz(2ppm). The water and fat seperation is 3.3ppm(about 140Hz at 1 Tesla magnet), the bandwidth is enough to resolve the difference. But we are more concerned about the narrow window in between the two peaks, in which the small quantity of metabolites reside. We performed the computer simulation and phantom experiments in 8*8 matrix form and showed good agreement in the image and spectrum. Finally we applied spectroscopic imaging to the brain of human subject. Only the lipid signal was shown in the periphery region which agrees with the at distribution in human head surface area. The spectrum inside the brain shows the important metabolites such as NAA, Cr/PCr, Choline. We here have shown the spectroscopic imaging which is normally done above 1.5 Tesla machine can be performed in the 1 Tesla Magnetic Resonance Imaging Unit.

  • PDF