• 제목/요약/키워드: T2 Measurement

검색결과 2,003건 처리시간 0.035초

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

원격자료수신장비 소형반사판 안테나 G/T 예측 및 측정 (The calculation and Measurement Methods for G/T of the Telemetry Small Aperture Antenna)

  • 김춘원;안나균;김동현;조병록
    • 한국항공우주학회지
    • /
    • 제50권9호
    • /
    • pp.657-662
    • /
    • 2022
  • 본 논문에서는 나로우주센터에서 운용 중인 원격자료수신장비의 G/T에 대한 시뮬레이션 활용 계산 결과와 측정 방법 2개에 대하여 분석하였다. 안테나 이득과 잡음 온도는 ICARA와 Antenna Noise Temperature Calculator를 이용하여 계산하였다. 시스템 G/T는 안테나 이득/잡음돈도와 LNA 이득/잡음온도, 케이블 손실을 반영하여 산출하였다. 첫 번째 G/T 측정 방법은 Y팩터 측정법으로 LNA 입력단에 안테나와 50ohm 터미네이션을 각각 연결했을 때의 신호 레벨 차이값을 LNA 열잡음 온도와 비교하여 G/T를 산출하는 방법이다. 두 번째 방법은 태양과 최저 레벨 지점을 바라보았을 때의 잡음 레벨 값 차이를 비교하여 G/T를 구하는 Solar Calibration 측정법이다. 마지막으로 G/T 계산결과와 두 측정법 비교를 통해 정확성을 검토하고 이로부터 안테나 성능, 운용환경에 따른 최적 측정법을 제시하였다.

An Automated Measurement System for the Microwave Surface Resistance of High-$T_c$ Superconductor Films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • 제2권1호
    • /
    • pp.27-32
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-$T_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-$T_c$ $YBa_2Cu_3O_{7-\delta}$ (YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K $\sim$ 90 K. An open-ended $TE_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded Q and the resonant frequency of the $TE_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-$T_c$ superconductor films is discussed.

  • PDF

An automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.173-178
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-T$_c$ YBa$_2$Cu$_3$O$_{7-{\delta}}$(YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K ${\sim}$ 90 K. An open-ended TE$_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded ${\varrho}$ and the resonant frequency of the TE$_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-T$_c$ superconductor films is discussed.

  • PDF

백서를 이용한 심자도 신호 측정 (Magnetocardiogram Measurement of Laboratory Rat)

  • 김인선;안산;권혁찬;송종현
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.147-151
    • /
    • 2010
  • We have developed a high-$T_c$ SQUID magnetocardiogram (MCG) system for small laboratory animals. White noise of the measurement system was about 30 fT/$Hz^{1/2}$ when measured in a magnetically shielded room. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 30 pT. We could observe well defined P-, QRS-, and T-waves from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of the heart disease model by using a laboratory rat.

웹 기반 학습 프로그램이 혈압측정에 대한 자기효능감, 지식 및 수행능력에 미치는 효과 (Effectiveness of web based learning program on self efficacy, knowledge, and competence in measurement of blood pressure)

  • 이숙희
    • 기본간호학회지
    • /
    • 제19권1호
    • /
    • pp.66-73
    • /
    • 2012
  • Purpose: This study was done to identify the effectiveness of a web based learning program on self efficacy, knowledge, and competence in measurement of blood pressure in college nursing students. Method: This study was an experimental research study. Data were collected from April 20 to June 1. 2011. The participants were 68 first year nursing students (experimental group 37, control group 31). The collected data were analyzed with the PASW 18.0 program, using ${\chi}^2$-test, t-test, and Cronbach's ${\alpha}$. Results: The mean score for self efficacy in blood pressure measurement in the experimental group was 61.9 and in the control group 60.7. This result was statistically significant (t=3.301, p=.002). The mean score for knowledge of blood pressure measurement in the experimental group was 11.5 and in the control group 10.8. This result was statistically significant (t=2.910, p=.005). But effectiveness of competence in blood pressure measurement was not significant. Conclusion: The study results show that the web based learning program was effective for self efficacy and knowledge in blood pressure measurement but not for competence indicating.-a need to develop strategies to improve competence in blood presessure measurement for these students.

IoT 기반 하이브리드 계측시스템 실시간 다점 측정 성능 평가 (Evaluation on real-time multi-point sensing performance of IoT-based hybrid measurement system)

  • 김헌영;강동훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.543-550
    • /
    • 2018
  • 4차 산업혁명의 도래와 함께 빠른 속도로 발전하고 있는 IoT 기술은 다양한 센서의 무선화를 가능하게 하였으며 많은 분야에서 응용연구가 활발히 진행되고 있다. 하지만, 철도현장의 경우 수 km에 이르는 교량, 터널 등 계측사이트의 규모가 매우 방대한 특징으로 인해, 보편적으로 활용되는 전기식 센서의 경우 원거리 계측으로 인한 신호 잡음 문제, 전철화에 따른 고전압 환경에 기인한 전자기파 간섭 문제로 계측에 어려움이 있다. 이를 극복하고자, 전기식 센서를 대체하기 위한 광섬유 센서 연구가 많이 수행되었으나, 센서 종류의 다양성 부족 등이 현장 적용의 한계로 작용하고 있는 실정이다. 이런 현장의 상황을 토대로, 전기식 센서와 광섬유 센서를 동시에 사용할 수 있으며 IoT 기술을 통해 무선 데이터 통신이 가능한 하이브리드 계측시스템이 개발되었다. 본 연구에서는, 선행연구를 통해 개발된 하이브리드 계측시스템의 다양한 계측현장 적용성을 평가하기 위해 4가지 형태의 계측환경을 모사하여 실시간 계측 실험을 수행하였다. 실험결과, 전기식 및 광학식 센서 모두 높은 추종성을 보이며 원격지에서 실시간으로 계측이 가능하였으며, 본 계측시스템이 50개의 센서를 동시에 2.5kHz의 샘플링으로 계측할 경우에도 적용 가능한 수준임을 확인하였다. 향후, IoT 기반 하이브리드 계측시스템의 다양한 현장 적용을 통해 실시간 건전성 모니터링 기술 기반의 구조안전성 향상에 기여할 것으로 기대한다.

DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교 (Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA)

  • 한범희;정홍량;임청환;이혜남;정천수;이상호
    • 한국콘텐츠학회논문지
    • /
    • 제10권3호
    • /
    • pp.250-257
    • /
    • 2010
  • 본 연구는 골밀도측정기 Norland와 Osteocore, Lunar 세 기종을 이용하여 각각 100명씩 총 300명을 대상으로 신체특징 중 연령, 신장, 체중으로 구분하여 측정오차를 비교분석하였으며, 요추부와 대퇴경부를 각각 정상(T-score$\geqq$-1.0), 골감소증(-1.0>T-score>-2.5), 골다공증(T-score>-2.5)으로 분류하여 각각의 그룹에서 측정오차를 비교분석하여 다음과 같은 결론을 얻었다. 연령과 신장에서 Norland측정기가 측정오차의 변화가 가장 적었으며, 체중에서는 Lunar측정기가 측정오차의 변화가 가장 적은 것으로 나타났다. 또한, 요추부를 기준으로 골밀도 측정오차를 비교한 결과 Lunar, Norland, Osteocore 세 기종 모두 골감소증에서 측정오차의 변화가 가장 적은 것으로 나타났고, 대퇴경부를 기준으로 골밀도 측정오차를 비교한 결과 Lunar, Norland, Osteocore 세 기종 모두 골다공증에서 측정 오차의 변화가 가장 적은 것으로 나타났다. 각 변수에 있어서 기종 마다 측정오차가 다르게 나타났으며, 이를 해결하기 위해서는 표준화된 공통 Phantom을 사용하여 각 회사의 측정치를 환산 비교하고, 소프트웨어의 교체에 따른 상호보정이 필요할 것으로 사료된다.

전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구 (A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag)

  • 장홍제;이한희;최효식;송태승;조원서
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.478-482
    • /
    • 2021
  • 본 논문에서는 버려지는 전기로산화슬래그를 재활용하여 차폐용 콘크리트를 제작하는데 있어 필요한 차폐효과 측정방법에 대하여 연구하였다. 차폐용 콘크리트 블록의 전자파 차폐효과를 측정하기 위한 시스템의 결과와 실제 콘크리트로 구축된 건축물의 차폐효과를 비교하여, 소형화된 콘크리트 블록의 전자파 차폐효과 측정 시스템의 유효성을 검증하였다. 콘크리트 건축물의 크기는 2.9 × 2.9 × 3.4m이고 콘크리트 블록은 0.3 × 0.3 × 0.2m로 차폐효과 측정 방법은 MIL-STD-188-125-1을 준용하였다. 비교하여 위하여 사용되는 주파수 대역은 600MHz - 2GHz이고 비교되는 콘크리트의 구성은 일반적인 콘크리트와 전기로산화슬래그가 포함된 콘크리트이다. 콘크리트 구조물의 경우에는 구조적 안전성을 위하여 철근이 15cm 간격으로 설치되어 있지만, 철근의 전자파 특성을 주파수가 증가할수록 차폐효과 특성이 점점 감소하기에 두 비교대상의 측정결과에서 약간의 차이가 발생하였다. 결론적으로는 콘크리트 블록을 통한 차폐효과 측정결과는 건축물을 만들었을 때의 결과와 유사하여, 전자파 엔지니어링 설계에 충분히 활용할 수 있을 것으로 생각되고 표준시편을 활용한 콘크리트의 차폐효과 측정 시스템이 유효함을 검증하였다.

위치/힘 동시제어를 위한 F/T측정 기능을 갖는 6축 순응기구 설계 (Design of a 6-axis Compliance Device with F/T Sensing for Position/Force Control)

  • 김한성
    • 한국산업융합학회 논문집
    • /
    • 제21권2호
    • /
    • pp.63-70
    • /
    • 2018
  • In this paper, the design of a novel 6-axis compliance device with force/torque sensing capability and the experiment results on force measurement are presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, the force control method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment for more stable force control. The proposed compliance device is designed to have a diagonal stiffness matrix at the tip and uses strain gauge measurement which is robust to dust and oil. The measurement circuit is designed with low-cost IC chips however the force resolution is 0.04N.