• Title/Summary/Keyword: T1-weighted imaging

Search Result 453, Processing Time 0.021 seconds

Hippocampal Sclerosis: Correlation of MR Imaging Findings with Surgical Outcome

  • Yoon Hee Kim;Kee-Hyun Chang;Sun-Won Park;Young Whan Koh;Sang Hyun Lee;In Kyu Yu;Moon Hee Han;Sang Kun Lee;Chun-Kee Chung
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.63-67
    • /
    • 2001
  • Objective: Atrophy and a high T2 signal of the hippocampus are known to be the principal MR imaging findings of hippocampal sclerosis. The purpose of this study was to determine whether or not individual MRI findings correlate with surgical outcome in patients with this condition. Materials and Methods: Preoperative MR imaging findings in 57 consecutive patients with pathologically-proven hippocampal sclerosis who underwent anterior temporal lobectomy and were followed-up for 24 months or more were retrospectively reviewed, and the results were compared with the postsurgical outcome (Engel classification). The MR images included routine sagittal T1-weighted and axial T2-weighted spin-echo images, and oblique coronal T1-weighted 3D gradient-echo and T2-weighted 2D fast spin-echo images obtained on either a 1.5 T or 1.0 T unit. The images were visually evaluated by two neuroradiologists blinded to the outcome; their focus was the presence or absence of atrophy and a high T2 hippocampal signal. Results: Hippocampal atrophy was seen in 96% of cases (55/57) [100% (53/53) of the good outcome group (Engel class I and II), and 50% (2/4) of the poor outcome group (class III and IV)]. A high T2 hippocampal signal was seen in 61% of cases (35/57) [62% (33/53) of the good outcome group and 50% (2/4) of the poor outcome group]. All 35 patients with a high T2 signal had hippocampal atrophy. 'Normal' hippocampus, as revealed by MR imaging, occurred in 4% of patients (2/57), both of whom showed a poor outcome (Engel class III). The presence or absence of hippocampal atrophy correlated well with surgical outcome (p<0.01). High T2 signal intensity did not, however, significantly correlate with surgical outcome (p>0.05). Conclusion: Compared with a high T2 hippocampal signal, hippocampal atrophy is more common and correlates better with surgical outcome. For the prediction of this, it thus appears to be the more useful indicator.

  • PDF

T1-weighted FLAIR MR Imaging for the Evaluation of Enhancing Brain Tumors: Comparison with Spin Echo Imaging (조영증강을 보이는 뇌종양의 평가에 있어 T1강조 FLAIR 영상과 스핀에코 MR 영상의 비교)

  • Jeong, Boseul;Choi, Dae Seob;Shin, Hwa Seon;Choi, Hye Young;Park, Mi Jung;Jeon, Kyung Nyeo;Na, Jae Beom;Chung, Sung Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.151-156
    • /
    • 2014
  • Purpose : Spin-echo (SE) technique is most commonly used pulse sequence for T1-weighted MR imaging. T1-weighted fluid-attenuated inversion recovery (T1FLAIR) is a relatively new pulse sequence and it provides higher tissue contrast between the gray matter (GM) and white matter (WM) of the brain than T1-weighted SE (T1SE) sequence. However, there has been controversy for the evaluation of enhancing brain tumors with T1FLAIR compared to T1SE. The purpose of this study was to compare T1FLAIR and T1SE sequences for the evaluation of enhancing intracranial tumors. Materials and Methods: Fifty-two patients with enhancing brain tumors were evaluated with contrast-enhanced (CE) T1SE and T1FLAIR imaging. Eight quantitative criteria were calculated: lesion-to-WM contrast ratio (CR) and contrast-to-noise ratio (CNR), lesion-to-GM CR and CNR, lesion-to-CSF CR and CNR, and WM-to-GM CR and CNR. For qualitative evaluation, two radiologists assessed lesion conspicuity on CE T1SE and T1FLAIR sequences with three-scale: 1, T1SE superior; 2, sequence equal; T1FLAIR superior. Results: Seventy-nine tumors (31 primaries, 48 metastases) were assessed. For quantitative measurement, the T1FLAIR lesion-to-GM, lesion-to-CSF, WM-to-GM CR and CNR values were comparable and statistically superior to those of the T1SE images (p < 0.001 in all). However, lesion-to-WM CR and CNR were similar on both two sequences without statistically significant difference (p = 0.661, 0.662, respectively). For qualitative evaluation, both radiologists assessed that T1FLAIR images were superior to T1SE images for the evaluation of lesion conspicuity. Conclusion: For the evaluation of enhancing intracranial tumors, T1FLAIR sequence was superior or comparable to T1SE sequence.

Bilateral Warthin tumor of the parotid gland: A case report (이하선에 발생된 양측성 Warthin 종양의 증례)

  • Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.57-62
    • /
    • 2008
  • The Warthin tumor is a benign neoplasm that occurs mostly in the parotid gland. The tumor frequently occurs in the tail of the parotid gland. A 75-year-old man was referred to Wonkwang dental hospital with a chief complaint of swelling on the right submandibular area. Numerous salivary stones were observed in the right submandibular gland on computed tomography (CT). And the two tumorous lesions were incidentally found in the parotid gland bilaterally. The tumorous lesions showed homogeneous enhancement on the CT and intermediate signal intensity on both T1- and T2-weighted magnetic resonance (MR) images. This tumorous lesions also showed contrast enhancement on fat suppressed T1 weighted MR images. We report common CT and MR features of this case of Warthin tumor in the parotid gland with literature review.

  • PDF

Evaluation by Contrast-Enhanced MR Imaging of the Lateral Border Zone in Reperfused Myocardial Infarction in a Cat Model

  • Ae Kyung Jeong;Sang Il Choi;Dong Hun Kim;Sung Bin Park;Seoung Soo Lee;Seong Hoon Choi;Tae-Hwan Lim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • Objective: To identify and evaluate the lateral border zone by comparing the size and distribution of the abnormal signal area demonstrated by MR imaging with the infarct area revealed by pathological examination in a reperfused myocardial infarction cat model. Materials and Methods: In eight cats, the left anterior descending coronary artery was occluded for 90 minutes, and this was followed by 90 minutes of reperfusion. ECG-triggered breath-hold turbo spin-echo T2-weighted MR images were initially obtained along the short axis of the heart before the administration of contrast media. After the injection of Gadomer-17 and Gadophrin-2, contrast-enhanced T1-weighted MR images were obtained for three hours. The size of the abnormal signal area seen on each image was compared with that of the infarct area after TTC staining. To assess ultrastructural changes in the myocardium at the infarct area, lateral border zone and normal myocardium, electron microscopic examination was performed. Results: The high signal area seen on T2-weighted images and the enhanced area seen on Gadomer-17-enhanced T1WI were larger than the enhanced area on Gadophrin-2-enhanced T1WI and the infarct area revealed by TTC staining; the difference was expressed as a percentage of the size of the total left ventricle mass (T2= 39.2 %; Gadomer-17 =37.25 % vs Gadophrin-2 = 29.6 %; TTC staining = 28.2 %; p < 0.05). The ultrastructural changes seen at the lateral border zone were compatible with reversible myocardial damage. Conclusion: In a reperfused myocardial infarction cat model, the presence and size of the lateral border zone can be determined by means of Gadomer-17- and Gadophrin-2-enhanced MR imaging.

  • PDF

Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging (최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용)

  • Oh, C.H.;Choi, H.J.;Yang, Y.J.;Lee, D.R.;Ryu, Y.C.;Hyun, J.H.;Kim, S.R.;Yi, Y.;Jung, K.J.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF

MR Imaging Characteristics of Primary T-Cell Lymphoma of the Cauda Equina: A Case Report and Literature Review (말총의 원발성 T세포 림프종에서 MR 영상 소견: 증례 보고와 문헌 고찰)

  • Younguk Kim;Guen Young Lee;Sujin Kim;Kwang-sup Song;Hee Sung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1613-1618
    • /
    • 2021
  • Primary central nervous system lymphoma is a rare form of extranodal non-Hodgkin lymphoma, and primary T-cell lymphoma of the cauda equina is extremely rare. We describe a case involving a 56-year-old female who presented with low back pain and radiating leg pain for 4 months. MRI of the lumbar spine revealed an elongated, multinodular intradural lesion of approximately 10 cm from the L4 body to the S2 body level with iso-signal intensity on T1-weighted imaging, heterogeneous iso- and high-signal intensity on T2-weighted imaging, and a heterogeneous intense enhancement on gadolinium contrast-enhanced T1-weighted imaging. A peripheral T-cell lymphoma of the cauda equina was diagnosed on the basis of immunohistochemical and T-cell receptor gamma gene rearrangement analysis after intradural biopsy of the mass.

High-resolution magnetic resonance imaging of teeth and periodontal tissues using a microscopy coil

  • Shinya Kotaki;Hiroshi Watanabe;Junichiro Sakamoto;Ami Kuribayashi;Marino Araragi;Hironori Akiyama;Yoshiko Ariji
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.276-282
    • /
    • 2024
  • Purpose: This study aimed to assess the performance of 2-dimensional (2D) imaging with microscopy coils in delineating teeth and periodontal tissues compared with conventional 3-dimensional(3D) imaging on a 3 T magnetic resonance imaging (MRI) unit. Materials and Methods: Twelve healthy participants (4 men and 8 women; mean age: 25.6 years; range: 20-52 years) with no dental symptoms were included. The left mandibular first molars and surrounding periodontal tissues were examined using the following 2 sequences: 2D proton density-weighted (PDw) images and 3D enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) images. Two-dimensional MRI images were taken using a 3 T MRI unit and a 47 mm microscopy coil, while 3D MRI imaging used a 3 T MRI unit and head-neck coil. Oral radiologists assessed dental and periodontal structures using a 4-point Likert scale. Inter- and intra-observer agreement was determined using the weighted kappa coefficient. The Wilcoxon signed-rank test was used to compare 2D-PDw and 3D-eTHRIVE images. Results: Qualitative analysis showed significantly better visualization scores for 2D-PDw imaging than for 3D-eTHRIVE imaging (Wilcoxon signed-rank test). 2D-PDw images provided improved visibility of the tooth, root dental pulp, periodontal ligament, lamina dura, coronal dental pulp, gingiva, and nutrient tract. Inter-observer reliability ranged from moderate agreement to almost perfect agreement, and intra-observer agreement was in a similar range. Conclusion: Two-dimensional-PDw images acquired using a 3 T MRI unit and microscopy coil effectively visualized nearly all aspects of teeth and periodontal tissues.

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

Detection of Malignant Primary Hepatic Neoplasms with Gadobenate Dimeglumine (Gd-BOPTA) Enhanced T1-Weighted Hepatocyte Phase MR Imaging: Results of Off-site Blinded Review in a Phase-II Multicenter Trial

  • Constantino S. Pena;Sanjay Saini;Richard L. Baron;Bernd A. Hamm;Giovanni Morana;Roberto Caudana;Andrea Giovagnoni;Andrea Villa;Alessandro Carriero;Didier Mathieu;Michael W. Bourne;Miles A. Kirchin;Gianpaolo Pirovano;Alberto Spinazzi
    • Korean Journal of Radiology
    • /
    • v.2 no.4
    • /
    • pp.210-215
    • /
    • 2001
  • Objective: To investigate the efficacy of gadobenate dimeglumine (GdBOPTA) enhanced MR imaging for the detection of liver lesions in patients with primary malignant hepatic neoplasms. Materials and Methods: Thirty-one patients with histologically proven primary malignancy of the liver were evaluated before and after administration of GdBOPTA at dose 0.05 or 0.10 mmol/kg. T1-weighted spin echo (T1W-SE) and gradient echo (T1W-GRE) images were evaluated for lesion number, location, size and confidence by three off-site independent reviewers and the findings were compared to reference standard imaging (intraoperative ultrasound, computed tomography during arterial portography or lipiodol computed tomography). Results were analyzed for significance using a two-sided McNemar's test. Results: More lesions were identified on Gd-BOPTA enhanced images than on unenhanced images and there was no significant difference in lesion detection between either concentration. The largest benefit was in detection of lesions under 1 cm in size (7 to 21, 9 to 15, 16 to 18 for reviewers A, B, C respectively). In 68% of the patients with more than one lesion, Gd-BOPTA increased the number of lesions detected. Conclusion: Liver MR imaging after Gd-BOPTA increases the detection of liver lesions in patients with primary malignant hepatic neoplasm.

  • PDF

Diagnosis of Meniscal Tear of the Knee Using Proton-weighted Fast Spin-Echo MR Imaging : Can be an Alternative to Conventional Spin-Echo Imaging\ulcorner (양지밀도강조 고속 스핀에코 자기공명영상을 이용한 슬관절 반월판 열상의 진단 : 고식적 스핀에코를 대체할 수 있는가\ulcorner)

  • 김기준;이재희;주종관;이성용
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.73-77
    • /
    • 1999
  • Purpose : The purpose of the study was to evaluate the sensitivity and specificity of proton-weighted fast spin-echo MR imaging in diagnosing the meniscal tear of knee as an reasonable substitute for conventional spin-echo imaging. Materials and Methods : 102 consecutive patients, proved by surgery, proved by surgery, were participated in this study. All of them were suspected internal derangement of knee, examined by fast spin-echo MR imaging including sagittal and coronal images on a 1.5T MR imager and underwent arthroscopic or open surgery of knee joint within 2 months. These images were reviewed retrospectively by three radiologists. The sensitivity and specificity of meniscal tear were calculated. Results : The sensitivity and specificity of meniscal tear using proton-weighted fast spin-echo MR imaging were 94%, 93% inmedialmeniscus and 92%, 88% in lateral meniscus. Conclusion : The sensitivity and specificity of meniscal tear using proton weighted fast-spin echo MR images were as high as those using conventional spin-echo images. The proton-weighted fast-spin echo MR imaging can be an alternative to conventional spin-echo MR imaging in diagnosing meniscal tear of the knee.

  • PDF