• Title/Summary/Keyword: T1-201 Scintigraphy

Search Result 10, Processing Time 0.023 seconds

T1-201 and I-131 Whole Body Scintigraphy in Postoperative Well-differentiated Thyroid Cancer (분화된 갑상선암 수술후 T1-201 및 I-131 전신신티그라피 소견)

  • Hyun, In-Young;Cha, Joong-Jik;Lee, Jin-Oh;Kang, Tae-Woong;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.87-92
    • /
    • 1990
  • T1-201 and I-131 scintigraphy were performed to visualize malignant lesions postoperatively in 26 patients with well-differentiated thyroid cancer. Anyone of uptake index and retention index was higher in malignant lesions than that in benign lesions. T1-201 scintigraphy showed uptake ininflammatory tissues. T1-201 concentration was observed in fourteen patients and six of them had malignant lesions, while I-131 concentration was observed in six patients and all had malignant lesions. In sensitivity, combination of T1-201 and I-131 scintigraphy is higher than I-131 or T1-201 scintigraphy only. In postoperative patients with well-differentiated thyroid cancer, it may be useful that T1-201 scintigraphy will be performed simultaneously with I-131 scintigraphy for detecting recurrence.

  • PDF

Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교)

  • Lee, Hyun-Kyung;Song, Jae-Soon;Shinn, Joon-Jae;You, Kye-Hwa;Cha, Wang-Ki;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.346-355
    • /
    • 1997
  • To evaluate the utility of I-131, T1-201 scintigraphy, and serum thyroglobulin(Tg) in the follow-up of differentiated thyroid cancer, we compared retrospectively the data from 33 patients who underwent total or subtotal thyroidectomy. I-131 scintigraphy was performed after optimal endogenous TSH stimulation ($TSH>50{\mu}U/ml$). Total 41 cases of I-131 and T1-201 scintigraphy pairs were examined. Concomitant serum thyroglobulin levels were measured for 41 pairs of scan. Tg-off levels(that measured after discontinuation of the thyroid hormone) higher than 40ng/m1 were considered positive, and Tg-on levels(that measured during the thyroid hormone replacement) higher than 5ng/ml were considered positive. The concordance rates between I-131 therapeutic scintigraphy and T1-201 scintigraphy was 48% in the 38 case of total scan pairs(59% in the 17 cases of postoperative preablation group, and 38% in the 21 cases of postoperative postablation group). Of 17 studies before the I-131 ablation therapy(preablation group), 7 showed positive I-131 therapeutic scintigraphy despite of negative T1-201 scintigraphy. Among patients with negative I-131 therapeutic scintigraphy, no patients had abnormal T1-201 uptake. However, of 21 studies which were done after radioiodine therapy(postablation group) 6 had abnormal uptake on T1-201 scintigraphy which were not seen on I-131 therapeutic scintigraphy, and Tg-off levels also elevated in this 4 of 6 cases. As a result, I-131 therapeutic scintigraphy showed highest positive rate at postoperative preablation follow-up study in differentiated thyroid cancer patients. T1-201 scintigraphy may be useful in postablation studies, and the use of the combined modalities(T1-201 and Tg levels) provides a higher diagnostic yield.

  • PDF

T1-201 Per Rectum Scintigraphy in Chronic Liver Disease: Assessment of T1-201 Uptake Indices (만성 간질환에서의 T1-201 경직장 문맥 신티그라피: T1-201 섭취 지표의 평가)

  • Moon, Won-Jin;Choi, Yun-Young;Cho, Suk-Shin;Lee, Min-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.49-56
    • /
    • 1999
  • Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.

  • PDF

The Role of Thallium-201 Scintigraphy in Bone and Soft Tissue Tumor (근골격계 종양에서 탈륨 스캔의 역할)

  • Shin, Duk-Seop
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.117-128
    • /
    • 2003
  • Thallium-201 scintigraphy is used to discriminate the malignant bone tumor from the benign by qualitatively and quantitatively, and to predict the response of preoperative chemotherapy in osteosarcoma, by comparing the changes of thallium uptake ratio after chemotherapy to the tumor necrosis ratio. Thallium-201 scintigraphy scan should be done prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator is usually used for scanning. The patient is injected with 2-3mCi of Tl-201 and the early phase is checked in 30 minutes and delayed phase in 3 hours. The scan images are visually evaluated by a blinded nuclear medicine physician. We could evaluate true positive, true negative, false positive and false negative by the comparison of results with those of biopsy, and calculate positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%). For the quantitative analysis of thallium uptake, we drew the region of interest on the tumor side and contralateral normal side as mirror image, and calculated the uptake ratio with dividing the amount of gamma count in tumor side by normal side. We could calculate the percent changes of thallium uptake ratio in early and delayed phase, and compare them to the ratio of tumor necrosis. Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors. We can use T1-201 scan to differentiate the benign from the malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy (우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의)

  • Lee, Do-Yun;Lee, Jong-Doo;Cho, Seung-Yun;Shim, Won-Heum;Ha, Jong-Won;Kim, Han-Soo;Kwon, Hyuk-Moon;Jang, Yang-Soo;Chung, Nam-Sik;Kim, Sung-Soon;Park, Chang-Yun;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

[ $^{201}T1/^{99m}Tc$ ] Subtraction Scan in the Diagnosis of Hyperparathyroidism ($^{201}T1/^{99m}Tc$ Pertechnetate 감영스캔을 이용한 부갑상선 항진증의 진단)

  • Ahn, Bo-Young;Sohn, Hyung-Sun;Kim, Euy-Neyung;Kim, Sung-Hoon;Chung, Soo-Kyo;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.460-464
    • /
    • 1995
  • [ $^{201}T1/^{99m}Tc$ ] pertechnetate subtraction scintigraphy of the parathyroid gland was performed in a study of 8 patients with clinical and biochemical evidence of hyperparathyroidism for diagnosis and Localization of the lesion prior to sugery. 6 cases of parathyroid adenomas were accurately localized and 2 cases of diffuse hyperplasia associated with chronic renal failure(CRF) and multiple endocrine neoplasia (MEN) type I. $^{201}T1/^{99m}Tc$ pertechnetate scan was useful for patients with hyperparathyroidism, especially in definite localization preoperatively.

  • PDF

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

The Study on the drug pharmacokinetics according to the progression of liver disease

  • Sohn, Soo-Jung;Choi, Hong-Serck;Ahn, Mee-Ryung;Chung, Hye-Joo;Yoo, Tae-Moo;Lee, Min-Ho;Park, Moon-Seung;Shin, In-Chul;Kim, Ju-ll
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.308.1-308.1
    • /
    • 2003
  • We underwent this study to know correlation between the amount of portosysternic shunt/hepatic fibrosis and bioavailability parameters such as AUC, Cmax, Tmax and t1 /2 of high extraction ratio drug, propranolol, in CCl4-induced liver cirrhosis model of rats. This study describes the bioavaility study of propranolol(5 mg/kg), Shunt Index using thallium-201 per rectum scintigraphy to to measure the amount of portosystemic shunt indirectly and intrahepatic hydroxyproline content performed in the CCl4-induced liver cirrhosis model of rats. (omitted)

  • PDF

Safety and Feasibility of Thallium-201 Myocardial SPECT with Intravenous Infusion of Disodium Adenosine Triphosphate (ATP) in the Diagnosis of Coronary Artery disease (관상동맥 질환 진단에서 ATP부하 T1-201 심근 관류 SPECT의 안전성과 유용성)

  • Pai, Moon-Sun;Park, Chan-H.;Yoon, Seok-Nam;Kim, Won;Kim, Han-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.250-258
    • /
    • 1998
  • Purpose: ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet been sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-201 myocardial SPECT using an intra-venous ATP infusion in patients with suspected coronary artery disease. Materials and Methods: Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/kg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Results: Although 76.5% of the patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Conclusion: Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease.

  • PDF

Lung/Heart Uptake Ratio and Transient Dilation Ratio of the Left Ventricle During Thallium-201 Imaging with Dipyridamole (Dipyridamole 부하를 T1-201 심근스캔에서 폐/심장 섭취율과 일과성 좌심실 확장율에 관한 연구)

  • Lee, Jae-Tae;Chung, Byung-Chun;Kim, Sang-Hyun;Lee, Kyu-Bo;Chae, Sung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.177-185
    • /
    • 1991
  • Dipyridamole thallium imaging is one of the most widely accepted means of evaluating patients with suspected or known coronay artery disease. The results of thallium imaging help diagnose coronary artery disesse (CAD), determine the hemodynamic significance of coronary stenosis, evaluate viability of myocardium, assess the outcome of therapeutic interventions and stratify patients according to their risk for luther cardiac events. An increased lung thallium uptake and transient LV dilation has been reported as poor prognostic indicator and associated with extensive and severe coronary artery disease. We quantitated lung/heart uptake ratio (l/HUR) and transient left ventricular dilation ratio in 44 patients and 17 controls undertaking dipyridamole thallium-201 scintigraphy. The results are as follows: 1) The lung/heart uptake ratio was high in patients with CAD and which became higher according to increasing number of diseased vessel. The L/HUR of patients with low LVEF (<35%) was lower than those with normal LVEF. 2) Transient left ventricular dilation ratio of CAD patients had no close relation between numbers of diseased vessels and was not higher than normals. But transient left ventricular dilation ratio of patients with myocardial infartion was higher than normals. We concluded that lung/heart uptake ratio seems to be sensitive marker for severity of CAD and myocardial function, but transient left ventricular dilation ratio alone is not sufficient to be a marker for severe and extensive CAD.

  • PDF