• 제목/요약/키워드: T-tube

검색결과 836건 처리시간 0.023초

다중버너 수관식 보일러를 위한 전열모듈의 열전달 특성: 0.5 t/h급 모형 수치해석 (Heat Transfer Module for Multi-Burner Water Tube Boiler: 0.5 t/h Class Model Simulation)

  • 안준;김종진;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.528-533
    • /
    • 2007
  • A finned tube type heat transfer module has been proposed for a multi-burner water tube boiler. Fins change their geometry along the streamwise direction to maximize the performance, which makes it difficult to apply conventional bulk analysis. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also performed to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, where the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

  • PDF

족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구 (Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination)

  • 문주완;한재복;최남길
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.39-46
    • /
    • 2018
  • 본 연구는 영상의학과에 내원한 족부환자를 대상으로 족부 X선 검사 시 주상골(navicular)의 관찰이 어려운 점을 바탕으로 환자의 position과 X선관 각도의 변화를 주어 어떠한 position과 X선관 각도에서 주상골의 관찰이 용이한지를 알아보고자 하였다. 주상골 관찰을 위해 실험대상자의 position은 Foot AP, internal oblique, external Oblique position의 세 가지로 하였다. T-F angle(Tibia-Foot angle)은 $90^{\circ}$$135^{\circ}$로 정의하였고, X선관 각도는 $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$로 정의하여 실험한 후 획득한 영상을 비교 평가하였다. 실험결과, Foot AP position에서 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 3%이었고 블라인드 테스트 결과는 4.89점으로 골절의 판독 용이성이 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.30점으로 판독 용이성이 가장 높았다. Foot internal oblique position에서는 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $0^{\circ}$일 때 설상골과 주상골의 겹침 정도는 4%이었고 블라인드 테스트 결과는 4.70점으로 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $0^{\circ}$일 때 그 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.55점으로 가장 높게 나타났다. Foot external oblique position에서 T-F angle이 $90^{\circ}$인 경우 X선관 각도가 $15^{\circ}$일 때 설상골과 주상골의 겹침 정도는 4%이었고 블라인드 테스트 결과는 4.85점으로 가장 높았으며, T-F angle이 $135^{\circ}$경우에는 X선관 각도가 $15^{\circ}$일 때 그 겹침 정도는 5%이었고 블라인드 테스트 결과는 4.75점으로 가장 높게 나타났다. 결론적으로, 본 연구를 통하여 X 선 족부검사에서 각 position에 해당하는 주상골 관찰에 용이한 T-F 각도와 X선관 각도를 확인할 수 있었으며, 향후 본 연구 결과를 바탕으로 주상골 골절 판독에 유용한 참고자료가 될 수 있을 것으로 여겨진다.

Fast initialization of a F!T tube

  • Willemsen, Oscar H.;Hoppenbrouwers, Jurgen J.L.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.122-125
    • /
    • 2003
  • We describe a new method to initialize the raster and convergence of a flat intelligent tracking (F!T) tube. By splitting up the initialization algorithm into three parts, it can comply with the variety of boundary conditions that are stated for a consumer product. Experiments on raster initialization have shown that the new algorithm speeds up the initialization by one order of magnitude.

  • PDF

Tensile capacity of mortar-filled rectangular tube with various connection details

  • Kim, Chul-Goo;Kang, Su-Min;Eom, Tae-Sung;Baek, Jang-Woon
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.339-351
    • /
    • 2022
  • A mortar-filled rectangular hollow structural section (RHS) can increase a structural section property as well as a compressive buckling capacity of a RHS member. In this study, the tensile performance of newly developed mortar-filled RHS members was experimentally evaluated with various connection details. The major test parameters were the type of end connections, the thickness of cap plates and shear plates, the use of stud bolts, and penetrating bars. The test results showed that the welded T-end connection experienced a brittle weld fracture at the welded connection, whereas the tensile performance of the T-end connection was improved by additional stud bolts inserted into the mortar within the RHS tube. For the end connection using shear plates and penetrating stud bolts, ductile behavior of the RHS tube was achieved after yielding. The penetrating bars increased load carrying capacity of the RHS. Based on the analysis of the load transfer mechanism, the current design code and test results were compared to evaluate the tensile capacity of the RHS tube according to the connection details. Design considerations for the connections of the mortar-filled RHS tubes were also recommended.

튜브뱅크 배열특성에 따른 전열특성변화 수치모사 (Numerical Simulation of Heat Transfer Characteristics of Tube Banks with Non-conventional Arrangement)

  • 전용두;남명환;구병수;이금배
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1129-1134
    • /
    • 2009
  • A numerical study has been conducted to investigate the effect of tube arrangement on the heat transfer and the pressure loss for cross flow heat exchangers. By defining a transverse deviation factor, ${\varepsilon}_t=l_T/S_T$, the flow pattern and the heat transfer characteristics are compared for selected ${\varepsilon}_t$ values of 0.0(in-lined), 0.1, 0.2, 0.3, 0.4, 0.5(staggered) by using a commercial software. Computational domain includes 1 pitch in the transverse direction and 5 pitches in the flow direction with due periodic boundary conditions.

  • PDF

온간액압성형공정 적용을 위한 알루미늄 6061, 7075 튜브의 열처리조건에 따른 변형특성연구 (A Study on Deformation Behaviors of Al 6061, 7075 Tube at Different Heat Treatments for Warm Hydroforming)

  • 이혜경;문영훈
    • 열처리공학회지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2007
  • The deformation behaviors of full annealed and T6 treated 6061, 7075 aluminum tubes are investigated at various temperature performing uniaxial tensile test. Full annealed Al 6061 and Al7075 tubes, and T6 treated Al7075 tube don't show sharp local necking with an elongation of 50% at $300^{\circ}C$. So it is expected that influenced by elevated tempterature. At $300^{\circ}C$ and strain rate of 0.001/s, many micro-cracks are observed in T6 treated Al 6061 tube, which is believed to be responsible for the decrease of total elongation.

비위관 영양방법 개선에 따른 간호효과 비교 (A comparison of nursing effects after the improvement of nasogastric tube feeding method)

  • 최자윤;장금성;황선영
    • 간호행정학회지
    • /
    • 제8권4호
    • /
    • pp.645-654
    • /
    • 2002
  • Purposes : This study was conducted to examine nursing effects after using a new method of nasogastric tube feeding with recycled PETE bottle making use of gravity, and to compare with those of bolus method using syringe and pressure. Methods : The data collected from patients with nasogastric tube feeding more than a week at an internal medicine unit of C university hospital located in G-city from January 1st, 1998 through June 30th, 2000. For this nonequivalent control group posttest non-synchronized design, 28 patients were assigned to an experimental group and 35 patients to a control group. The homogeneity of two groups and the dependent variables were tested with use of $x^2-test$ and t-test. Results : The duration of hemostatic use was significantly shorter in the experimental group than control group(t=2.63, p=0.02). Also, the patients with PETE bottle feeding had a lower cost of material(t=3.51, p=0.01) and a lower rate of the time of direct nursing care(t=2.44, p=0.04) than those of control group. But, there was no significant difference between two groups in the length of hospital stay. Conclusion : This results indicates that nasogastric tube feeding with PETE bottle is superior to nasogastric tube feeding with syringe. This findings gave us an evidence to enhance nursing effectiveness in clinical setting.

  • PDF

해양 응급상황 알림을 위한 TPMS 디바이스와 모바일 앱 시스템 개발 (Development of TPMS Device and Mobile App System for Marine Emergency Notification)

  • 공동환
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권3호
    • /
    • pp.49-53
    • /
    • 2024
  • 해양 안전은 바다에서의 사고로부터 인명을 보호하고, 보다 안전한 해양 환경을 조성하는 데 중요한 요소다. 본 연구에서는 해양 안전을 향상시키기 위한 TPMS 디바이스를 개발하고, 이를 통해 바다에서의 사고 상황을 감지하고 신속한 대응을 가능케 하는 기술적 솔루션을 제시한다. 이를 위해 개발한 튜브 압력 측정 시스템(TPMS)을 활용하여 튜브의 팽창을 감지하고, 실시간으로 데이터를 수집하여 주변 기기와 통신함으로써 빠른 대응이 가능하도록 설계되었다. 실험 결과를 통해 TPMS(Tube Pressure Monitoring System)가 효과적으로 압력을 감지하고, Main IoT 디바이스와 통신하며 안정적인 데이터 송수신이 가능함을 확인하였다. 또한 비상 상황에 빠르게 대응할 수 있도록 비상 상황 알림 메시지를 수신하고 정보를 조회할 수 있는 모바일 앱을 개발하였다. 개발한 디바이스와 모바일 앱은 해양 안전 분야뿐만 아니라 다양한 응용 분야에서도 활용 가능한 기술을 포함하고 있으며, 향후에는 실제 현장에서의 적용 가능성을 확대할 것이다. 이러한 결과는 해양 환경의 안전성을 높이는 데 기여할 것으로 기대된다.

Successful Management of Delayed Esophageal Rupture with T-Tube Drainage Using Video-Assisted Thoracoscopic Surgery

  • Do, Young Woo;Lee, Chang Young;Lee, Sungsoo;Kim, Ha Eun;Kim, Bong Jun;Lee, Jin Gu
    • Journal of Chest Surgery
    • /
    • 제49권6호
    • /
    • pp.478-480
    • /
    • 2016
  • Spontaneous perforation of the esophagus after forceful vomiting is known as Boerhaave syndrome, a rare and life-threatening condition associated with a high rate of mortality. The management of Boerhaave syndrome is challenging, especially when diagnosed late. Herein, we report the successful management of late-diagnosed Boerhaave syndrome with T-tube drainage in a 55-year-old man. The patient was transferred to our institution 8 days after the onset of symptoms, successfully managed by placing a T-tube, and was discharged on postoperative day 46 without complications.

Syringo-Subarachnoid-Peritoneal Shunt Using T-Tube for Treatment of Post-Traumatic Syringomyelia

  • Kim, Seon-Hwan;Choi, Seung-Won;Youm, Jin-Young;Kwon, Hyon-Jo
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권1호
    • /
    • pp.58-61
    • /
    • 2012
  • Various surgical procedures for the treatment of post-traumatic syringomyelia have been introduced recently, but most surgical strategies have been unreliable. We introduce the concept and technique of a new shunting procedure, syringo-subarachnoid-peritoneal shunt. A 54-year-old patient presented to our hospital with a progressive impairment of motion and position sense on the right side. Sixteen years before this admission, he had been treated by decompressive laminectomy for a burst fracture of L1. On his recent admission, magnetic resonance (MR) imaging studies of the whole spine revealed the presence of a huge syrinx extending from the medulla to the L1 vertebral level. We performed a syringo-subarachnoid-peritoneal shunt, including insertion of a T-tube into the syrinx, subarachnoid space and peritoneal cavity. Clinical manifestations and radiological findings improved after the operation. The syringo-subarachnoid-peritoneal shunt has several advantages. First, fluid can communicate freely between the syrinx, the subarachnoid space, and the peritoneal cavity. Secondly, we can prevent shunt catheter from migrating because dural anchoring of the T-tube is easy. Finally, we can perform shunt revision easily, because only one arm of the T-tube is inserted into the intraspinal syringx cavity. We think that this procedure is the most beneficial method among the various shunting procedures.