• 제목/요약/키워드: T-factor

검색결과 7,085건 처리시간 0.042초

CLS 시편의 탄성일인자 유도 및 이를 적용한 열가소성 Graphite/Peek 복합재의 파괴인성 $G_c$ 측정 (Elastic Work Factor of CLS Specimen and Determination of $G_c$ for Graphite/Peek Composites by Using the Elastic Work Factor)

  • 이경엽
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2792-2799
    • /
    • 1996
  • It was shown in the previous study that the numerically derived elastic work factor for CLS specimen was independent of fiber direction for a unidirectional case. Also, it was proposed the elastic work factor could be used to determine energy release rate from a single test record. In the present study, elastic work factor was derived from a simple beam theory to investigate its dependence on material property and geometric condition. Also, the elastic work factor of CLS specimen was applied experimentally to determine critical energy release rate in order to prove its validity determining critical energy release rate from a single specimen. For this purpose, critical energy release rate determined using the elastic work factor was compared with that determined by the compliance method. The results showed that while elastic work factor is affected by $t_2/t_1$ and $L_2/L_1$ it is independent of fiber angle for a unidirectional case. It was also found that critical energy release rates determined by both methods are comparable each other, thus elastic work factor approach can be used to determine energy release rate from a single test specimen.

Simian virus 40의 T항원 도입으로 수립한 지방유래줄기세포주의 효율적인 무혈청 배양법 및 무혈청 배지조성 (Composition of a Medium for Serum-free Culture of an Adipose-derived Stem Cell Line Established with a Simian Virus 40 T Antigen)

  • 김규빈;주우홍;김동완
    • 생명과학회지
    • /
    • 제24권12호
    • /
    • pp.1301-1307
    • /
    • 2014
  • 지방유래줄기세포(adipose-derived stem cell; ADSC)는 조직재생을 위한 탁월한 수단으로 인정되고 있으나 세포증식속도가 느려 ADSC의 배양용 배지에는 대게 fetal bovine serum (FBS)이 첨가된다. FBS는 세포에 다양한 영양분을 공급하지만 세포의 기능에 영향을 미칠 수 있는 미 동정 물질도 많이 함유하고 있다. FBS에 의한 예상밖의 영향과 동물유래물질의 오염을 방지하기 위해 ADSC의 무혈청 배양법에 관한 연구가 광범위하게 이루어지고 있다. 본 연구에서는 ADSC세포에 SV40의 T항원 유전자를 도입하여 증식속도를 향상시킨 ADSC-T세포주의 효율적인 무혈청 배양법을 확립하기 위해 ADSC-T의 세포증식에 미치는 아미노산복합체, 비타민 복합체 및 여러가지 영양분 혼합물(B27)의 영향을 검토하였다. 그 결과, ADSC-T세포를 DMEM/F12 무혈청 배지에 현탁하여 plate에 주입하였을 때는 증식하지 않았으며 아미노산, 비타민 및 B27 영양소복합체는 증식촉진효과를 나타내지 않았다. 그러나 ADSC-T세포를 유혈청 DMEM배지로 24시간 배양 후 DMEM/F12 무혈청 배지로 교체하여 배양했을 때는 세포가 증식하였으며 이때, 비타민 복합체와 B27 영양소복합체는 증식촉진효과를 나타내었다. 또한 Stem pro 배지를 이용하면 ADSC-T의 무혈청 부유배양이 가능한 것으로 나타났다. ADSC-T세포는 분자량 70 kDa 부근의 단백질을 다량으로 분비하였으며, 성장인자 중에서 insulin-like growth factor (IGF)와 fibroblast growth factor basic (FGF basic)는 유혈청 배양보다 무혈청 배양에서 더 많이 분비되었다.

5-블레이드 배플이 설치된 로켓엔진 연소실에서의 상온음향 해석 (Acoustic Analysis of KSR-III Combustion Chamber with Various 5-Blade Baffles under Non-Reacting Condition)

  • 김홍집;김성구;손채훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.167-171
    • /
    • 2003
  • Acoustic characteristics of baffled combustion chamber to elucidate suppressing effect of baffle on combustion instability are numerically investigated by linear acoustic analysis. A hub-blade baffle of 5 blades is selected as a candidate one and five variants of baffles with various configuration are designed. Resonant-frequency shift and damping factor are analyzed quantitatively as damping parameters. When the hub is located radially at the pressure node, the decrease of resonant frequency and increase of damping factor in 1R mode are dominant. But sub-1T mode is formed within hub, therefore, there would be a possibility of initiating 1T mode in unbaffled region, which would occur another problem. For smaller hub size, four kinds of axial baffle length is selected. As the axial baffle length increases, resonant frequency shift and increase of damping factor of transverse acoustic modes is obtained. Especially, two close acoustic modes such as 1L and 1T could be overlapped for a certain axial length, resulting in extreme increase of damping factor. The present study based on linear acoustic analysis is expected to be a useful confirming tool to predict acoustic field and design a passive control devices such as baffle and acoustic cavity.

  • PDF

ZnO의 과잉첨가가 Ba(${Zn}_{1/3}{Ta}_{2/3}$)$O_3$세라믹스의 마이크로파 유전특성에 미치는 영향 (Effect of Excess ZnO on Microwave Dielectric Characteristics of Ba(${Zn}_{1/3}{Ta}_{2/3}$)$O_3$ Ceramics)

  • 이두희;윤석진;박창엽
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.613-619
    • /
    • 1994
  • Dielectric properties of Ba(ZnS11/3TTaS12/3T)OS13T+x ZnO(x=0, 0.4, 0.8, 1.0 wt%) ceramics have been investigated at microwave frequencies. With excess ZnO, the sinterability was improved and the dielectric constant($\varepsilon$S1rT) and the unloaded quality factor(QS1UT) were increased. The structure changed into hexagonal from pseudocubic as being annealed at 140$0^{\circ}C$ in excess ZnO composition. Also, the temperature coefficient of the resonant frequency ($\tau$S1fT) turned into (-)ppm/$^{\circ}C$ when sintered at 155$0^{\circ}C$ for 2 hours. But the specimen sintered in ZnO muffling showed increased density and $\varepsilon$S1rT but lowerde QS1uT. Among the specimen investigated, expecially the composition added with 0.4wt% excess ZnO showed the most optimum dielectric values ($\varepsilon$S1rT=28, QS1uT x f=120000GHz) better than those of original Ba(ZnS11/2T TaS12/3T)OS13T ceramics.

  • PDF

BaO-Sm2O3-TiO2 세라믹스의 마이크로파 유전특성에 미치는 어닐링 효과 (Annealing Effect on the Microwave Dielectric Properties of the BaO-SmS12TOS13T-TiOS12T Ceramics)

  • Lee, Geun-Ill;Chung, Jang-Ho;Lee, Young-Hie
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.789-794
    • /
    • 1994
  • In this study, the structural and microwave dilelectric properties of 0.15BaO-0.15SmS12TOSI3T-0.7TiOS12T ceramics with sintering and annealing conditions were investigated. In the specimen sintered at 1350 [$^{\circ}C$], dielectric constant and quality factor were good values of 80.19,2006 (fS10T=4.6851[GHz]). To improve the $\tau$S1fT of specimen which was manufactured by the optimumsintering condition (1350[$^{\circ}C$],2[Hr.]), annealed from 2[hr.] to 16[hr.] at the annealing temperature of 1200 [$^{\circ}C$]. Increasing the annealing time, dielectric constant was almost constant and quality factor was increased. In the specimen of 4[hr.] annealed, the temperature coefficient of resonant frequency was minimum value, and increased with increasing the annealing time.

Factor Analyses for Water Quality Indicators of Streams, Ground Water, and Reservoir in Agricultural Small Catchments of the Han River Basin

  • Park, C-S;Joo, J-H;Jung, Y-S;Yang, J-E
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.382-393
    • /
    • 2000
  • The principal indicators contributing to water qualities was screened by factor analyses, based on the monitored chemical parameters of water quality for various water resources from 1995 to 1999 in the small agricultural catchments of the Han River Basin. Water samples of streams, groundwaters, and reservoirs were taken four times a year from upper (Daegwanryong), middle (Dunnae and Chunchon) and lower (Guri) reaches of Han River Basin. In these areas, the respective type of farming practiced was alpine agriculture and livestocks raising, typical upland and paddy cultivation, and intensive cropping in the plastic film house. Water quality was monitored for twenty-one water quality parameters, including pH, EC, SS, T-N, T-P, COD, cations, anions, and heavy metals. pH, EC and COD of the stream waters were suitable for the Korea irrigation water quality guidelines. However, T-N and T-P concentrations of water samples in four catchments far exceeded the irrigation water guideline. Concentrations of canons and heavy metals in Wangsuk stream in Guri area were higher than those in streams in other areas. Factor analysis revealed that significant correlation was observed for 81 pairs out of 231 water quality indicators of stream water among the $21\;{\times}\;21$ cross correlation matrix of stream water quality indicators. The first factor accounted for 27.01% of the total variation in stream water quality indicators, and high positive factor loadings were shown on EC, K, Na, $NH_4\;^+-N$, $PO_4\;^{3-}$, $SO_4\;^{2-}$, and COD. Fifty-three water quality indicator pairs were significant out of 190 ground water quality parameters. The first factor accounted for 28.54% of the total variation in ground water quality indicators, and high loadings were revealed on EC, Ca, Mg, K, Na, $NH_4\;^+-N$, and $SO_4$. Twenty-nine pairs of reservoir water quality indicators were significant out of 66 pairs. The first factor accounted for 37.06% of the total variation in reservoir water quality indicators, and high loadings were shown on EC, Mg, K, Na, SS, T-P, Cl, and COD. These results demonstrate that EC was the first factor contributing to water quality.

  • PDF

한국어판 임상학습환경과 슈퍼비전, 임상실습지도교수(CLES+T) 측정도구의 타당도와 신뢰도 (Validity and Reliability of the Korean Version Scale of the Clinical Learning Environment, Supervision and Nurse Teacher Evaluation Scale (CLES+T))

  • 김선희;유소연;김예영
    • 대한간호학회지
    • /
    • 제48권1호
    • /
    • pp.70-84
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the validity and reliability of the Korean version of the clinical learning environment, supervision and nurse teacher evaluation scale (CLES+T) that measures the clinical learning environment and the conditions associated with supervision and nurse teachers. Methods: The English CLES+T was translated into Korean with forward and back translation. Survey data were collected from 434 nursing students who had more than four days of clinical practice in Korean hospitals. Internal consistency reliability and construct validity using confirmatory and exploratory factor analysis were conducted. SPSS 20.0 and AMOS 22.0 programs were used for data analysis. Results: The exploratory factor analysis revealed seven factors for the thirty three-item scale. Confirmatory factor analysis supported good convergent and discriminant validities. The Cronbach's alpha for the overall scale was .94 and for the seven subscales ranged from .78 to .94. Conclusion: The findings suggest that the 33-items Korean CLES+T is an appropriate instrument to measure Korean nursing students'clinical learning environment with good validity and reliability.

반도체패키지에서의 층간박리 및 패키지균열에 대한 파괴역학적 연구 (1) -층간박리- (A Fracture Mechanics Approach on Delamination and Package Crack in Electronic Packaging(l) -Delamination-)

  • 박상선;반용운;엄윤용
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.2139-2157
    • /
    • 1994
  • In order to understand the delamination between leadframe and epoxy molding compound in an electronic packaging of surface mounting type, the stress intensity factor, T-stress and J-integral in fracture mechanics are obtained. The effects of geometry, material properties and molding process temperature on the delamination are investigated taking into account the temperature dependence of the material properties, which simulates as more realistic condition. As the crack length increases the J-integral increases, which suggest that the crack propagates if it starts growing from the small size. The effects of the material properties and molding process temperature on stress intensity factor, T-stress is and J-integral are less significant than the chip size for the practical cases considered here. The T-stress is negative in all eases, which is in agreement with observation that interfacial crack is not kinked until the crack approaches the edge of the leadframe.

Regulation of Nrf2 Mediated Phase II Enzymes by Luteolin in human Hepatocyte

  • Park, Chung Mu
    • 대한의생명과학회지
    • /
    • 제20권2호
    • /
    • pp.56-61
    • /
    • 2014
  • This study attempted to confirm the antioxidative potential of luteolin against tert-butyl hydroperoxide (t-BHP) induced oxidative damage and to investigate its molecular mechanism related to glutathione (GSH)-dependent enzymes in HepG2 cells. Treatment with luteolin resulted in attenuation of t-BHP induced generation of reactive oxygen species (ROS) and oxidative stress-mediated cell death. In addition, accelerated expression of GSH-dependent antioxidative enzymes, glutathione peroxidase (GPx) and glutathione reductase (GR), and heme oxygenase (HO)-1, as well as strengthened GSH content was induced by treatment with luteolin, which was in accordance with increased nuclear translocation of nuclear factor-erythroid 2 p45-related factor 2 (Nrf2), a transcription factor for phase 2 enzymes, in a dose-dependent manner. These results suggest that the cytoprotective potential of luteolin against oxidative damage can be attributed to fortified GSH-mediated antioxidative pathway and HO-1 expression through regulation of Nrf2 in HepG2 cells.