• Title/Summary/Keyword: T-N 제거

Search Result 442, Processing Time 0.023 seconds

Nutrients Removal Efficiency by Vegetation Density on Constructed Wetland from Small Watershed (소수계 유역 인공습지에서 식생 밀도 차이에 다른 영양염류 제거효율)

  • Ko, Jee-Yeon;Kang, Hang-Won;Lee, Jae-Sang;Kim, Chun-Song;Sakadevan, K.;Bavor, H.J.
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.266-272
    • /
    • 2003
  • This study was conducted to evaluate effects of 2 constructed wetlands with different vegetation states (plumpton park wetland and Woodcroft park wetland) for reducing non-point source pollution from small watershed consisted of residential and agricultural area in suburban district of Sydney, Australia. The total nitrogen and phosphate removal efficiency of Plumpton park constructed wetland, composed of stable and dense vegetation, were 38.3% and 26.2% and Woodcroft park constructed wetland having still poor vegetation due to the short time to settle down transplanted plants after construction, showed relatively low removal efficiency of 20.2% and 14.0%. The removal efficiency of inorganic nutrients such as $NH_4-N$, $NO_3-N$, $PO_4^{-3}$ were higher than total nitrogen and phosphate because plants and microorganisms in rhizosphere of constructed wetlands took up inorganic nutrients shortly. According to the type of wetland inflow, the nutrients removal efficiency of storm water flow was lower than base flow.

The Removal of Organics and Nutrients in an Anoxic/Oxic Process Using Surface-modified Media (표면개질 담체를 이용만 무산소/호기 공정에서의 유기물 및 영양염류 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2008
  • Surface of hydrophobic media was modified to become hydrophilic by ion beam irradiation. Fixed bed biofilm reactors packed with or without surface modification were used to remove organics, nitrogen, and phosphorus from sewage. This system composed of anoxic/oxic cycles to increase the nutrient removal. A cylindrical polyethylene was used as a packing media in this study. With 12 hours of hydraulic retention time (HRT), the reactors with and without surface modification showed 95% and 92% $COD_{cr}$ removal, respectively. Both reactors showed over 95% $COD_{cr}$ removals for a longer HRT of 16 hours. Nitrogen removal ranged 54.8% to 70.2% for the surface modified system and 57.5% to 76.5% for the non-modified system under same condition. Finally, phosphorus removal ranged 59.4% to 69.8% for the surface modified system and 51.3% to 63.4% for the non-modified system under same condition. From this study organics and phosphorus were better removed in using surface modified media and vice versa for nitrogen removal.

A study on the desulfurization wastewater treatment using Ferrate(VI) (Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구)

  • Jo, Eun-young;Park, Chan-gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

Reusing of Dye Wastewater through Combined Membrane Process (조합형 분리막 공정을 이용한 염색폐수의 재이용 연구)

  • 박헌휘;최호상
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2002
  • Submerged membrane bioreactor(SMBR) and reverse osmosis(R/O) systems treated dye wastewater for reusing of industrial water. The permeate fluxes of SMBR at 20-25 cmHg of lab. test and field test were 10 LMH($1/m^2$.hr) all test. Removal efficiencies of CODcr, $COD_{Mn}$ and T-N were 93%, 90% and 60% in the SMBR, respectively The advanced treatment of combined process(SMBR+R/0) was accomplished for increasing the removal efficiency of non-biodegradable materials and T-N. Therefore, the removal efficiency of T-N obtained in 80% above, then nitrogen concentration was under 15 mg/L. The combined process(SMBR+R/0) was suitable to reuse of the dye wastewater.

A Study on the Removal of Nitrogen and Phosphorus by Addition of Coagulant in the Sulfur Denitrification Process Coupled to the Membrane Bioreactor (MBR과 황탈질 공정에서 응집제 주입에 따른 질소.인 제거에 관한 연구)

  • Lee, Young-Ho;Yoo, Soung-Jong;Oh, Dae-Min;Lee, Young-Sin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.949-956
    • /
    • 2010
  • A method for simultaneous removal of nitrogen and phosphate from sewage by elemental sulfur denitrification with membrane bioreactor was proposed, and capacity $10\;m^3$/day of pilot plant was operated for 350 days. This study was investigated to have the effect of denitrification rate and T-P removal with the addition of Alum in Sulfur denitrification Reactor (SDR). The addition of Alum and alkalinity ($NaHCO_3$) in the effluent of MBR was tried to remove simultaneous phosphate and nitrogen in SDR. Characteristics of total nitrogen (T-N) and total phosphate (T-P) removal was compared without and with the addition of Alum as a coagulant. T-N removal without and with the addition of Alum was 92.1% and 87.8%, respectively. And denitrification efficiency was 93.8% and 87.1%, respectively. T-P removal rate was increased to 75.6% in SDR by addition of Alum (2.6~4 mg/L as Al), but T-P removal rate was about 26.7% without the addition of Alum. Therefore, denitrification rate was 6.7% of reduction but T-P removal rate was increased by addition of Alum.

Further Treatment of Constructed Wetland Effluent using Filter Materials (여재를 이용한 인공습지 유출수 추가처리)

  • Haam, Jong-Hwa;Kim, Hyung-Joong;Kim, Yeong-Kyung
    • Journal of Wetlands Research
    • /
    • v.11 no.2
    • /
    • pp.9-16
    • /
    • 2009
  • Further treatment facility using various filter materials was evaluated to treat effluent of constructed wetland. Further treatment facility was installed with 1m length in outlet of 3 constructed wetland (unplanted constructed; reed bed constructed wetland; cattail bed constructed wetland) using 3 filter materials (slag, activated carbon, oyster shell). Flow rate of three further treatment facility was 63 $m^3$/day (slag), 19 $m^3$/day (activated carbon), and 81 $m^3$/day (Oyster shell). COD removal rate of slag, activated carbon, and oyster shell was 6 %, 24 %, 1 %, and removal mass was 32 g/day, 30 g/day, and 5 g/day, respectively. All of further treatment facility was effective to removal organic materials. T-N and T-P removal rate of activated carbon was 24 % and 4 %, and slag and oyster shell was not effective to remove T-N and T-P. Overall, further treatment facility was effective to remove organic mater, constructed wetland combined with further treatment facility can remove nutrient and organic matters effectively.

  • PDF

Evaluation on Odor Removal Performance of Bacteria-Based Odor Reduction Kit for Revetment Blocks (호안블록용 박테리아 기반 악취저감 키트의 악취제거 성능평가)

  • Keun-Hyoek Yang;Ju-Hyun Mun;Ki-Tae Jeong;Hyun-Sub Yoon;Jae-Il Sim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.229-238
    • /
    • 2024
  • This study evaluated the odor removal performance of a bacteria-based odor reduction kit. The bacteria used were Rhodobacter capsulatus, Paracoccus limosus, and Brevibacterium hankyongi, which can remove ammonia (NH3), hydrogen sulfide (H2S), total nitrogen (T-P), and total phosphorus (T-N), which are odor pollutants. The materials used were bacteria and porous aggregates (expanded vermiculite, zeolite beads, activated carbon), and the combination of the materials varied depending on the removal mechanism. Materials with a physical adsorption mechanism (zeolite beads and activated carbon) gradually slowed down the concentration reduction rate of odor pollutants (NH3, H2S, T-P, and T-N), and had no further effect on reducing the concentration of odor pollutants after 60 hours. Expanded vermiculite, in which bacteria that remove odors through a bio-adsorption mechanism were immobilized, had a continuous decrease in concentration, and the concentration of odor pollutants reached 0 ppm after 108 hours. As a result, the odor removal performance of materials with physical adsorption mechanisms in actual river water did not meet the odor emission standard required by the Ministry of Environment, while the expanded vermiculite immobilized with bacteria satisfied the odor emission permissible standard and achieved water quality grade 1.

A Study on Optimum HRT Combination for Efficient Nitrogen Removal at WWTP in Winter Days (동절기 하수처리장에서 효율적인 질소제거를 위한 최적 HRT조합 도출에 관한 연구)

  • Gil, Kyung-Ik;Lee, Un-Gil;Rho, Hae-Yeon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.165-169
    • /
    • 2008
  • It has been reported that most wastewater treatment plants have difficulties in nitrogen removal during winter season due to declined activity of nitrifiers in the condition of low temperature. This study was conducted in order to find out optimum operating condition for efficient nitrogen removal in low temperature. A series of operating conditions with various HRTs of each tank were simulated using the GPS-X program. The optimum HRT combination for effective nitrogen removal was 0.3 hr/0.5 hr/1.36 hr/4.84 hr(PreAx/An/Ax/Ox) with 51.4% of T-N removal efficiency and 57.3% of $NH_4^+$-N removal efficiency.

Remediation of Sediments using Micro-bubble (미세기포를 이용한 퇴적물 정화)

  • Kang, Sang Yul;Kim, Hyoung Jun;Kim, Tschung Il;Park, Hyun Ju;Na, Choon Ki;Han, Moo Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.420-427
    • /
    • 2016
  • This study was conducted on the sediment remediation using micro-bubble to remove fine particles. For this study, characteristics of contamination and release in sediment were analyzed. And then, the characteristics of bubbles on removal efficiency was investigated at various operation conditions. In particle size distribution of the sediment used for the study, the proportion of clay and silt (<0.075 mm) was about 7.7%, sand (0.075~4.75 mm) was about 67.8%, and gravel (${\geq}4.75$) was 24.5%. Total nitrogen (TN) and total phosphorus (TP) of the sediment were 2,790~3,260, 261~311 mg/kg respectively. Ignition loss and water content were 4.1~9.6, 32.9~53.2% respectively. In analysis of removal efficiency according to operation conditions of micro-bubble, it was the highest when operation condition is pressure 6 atm, pressurized water ratio 30%, and coagulant dosage 15 ppm. At the time, the sediment's removal efficiency was 19.9%. Accordingly removal efficiency of TN and TP were 21.4, 22.6% respectively. Finally a research was found that fine particles in sediment were almost removed by micro-bubble, which led to decrease nutrients' release at about 20.1~64.3% in comparison to sediment including lots of fine particles.

토양컬럼을 이용한 도금공장 유출수의 고도처리

  • Jeong, Gyeong-Hun;Kim, Se-Yeong;Im, Byeong-Gap;Choe, Hyeong-Il;Park, Sang-Il;Kim, Yeong-Ju
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.377-381
    • /
    • 2006
  • 실험실 규모의 토양컬럼을 사용하여 도금폐수처리장의 유출수를 대상으로 처리한 결과 다음과 같은 결론을 얻었다. 1) 유입수 $NH_4-N$의 대부분은 질산화 토양컬럼에서 질산화 되었으며 HRT가 단축되면 제거율이 낮아졌다. 2) 질산화 토양컬럼에서 생성된 $NO_3-N$은 탈질 토양컬럼에서 탄소원이 없으면 탈질이 이루어지지 않지만 탄소원으로 메탄올을 주입하면 대부분의 $NO_3-N$는 탈질되었다. 3) 탈질 토양컬럼에서 HRT 72시간일때 T-N 제거율은 81.5%이었고 HRT 48시간일 때는 77.8%이었다. 4) 유입수 평균 T-P농도는 13.06 mg/L이고 탈질 토양컬럼에서의 유출수 평균 T-P는 0.83 mg/L로 제거율은 96.83% 이었다. 5) 실험기간 동안의 COD변화는 탄소원으로 메탄올 주입했 때와 HRT 변화시를 제외하고는 25 mg/L이하로 처리되었으며, 질산화 토양컬럼에는 폐굴껍질을 충진한 결과 $NO_3-N$의 생성에도 불구하고 pH 8.5정도를 유지할 수 있었다.

  • PDF