• Title/Summary/Keyword: T-Junction

Search Result 399, Processing Time 0.028 seconds

Experimental Study on Flow Noise in a T-Junction Pipe at Different Flow Velocity (유동속도에 따른 T-접합관의 유동소음에 관한 실험적 연구)

  • Jian-bin Hu;Hou-lin Liu;Kai Wang;Guang-xin Ding;Yu-bo Jin;He-ming Liu;Hyoung-bum Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.55-62
    • /
    • 2024
  • Using an internal flow noise test bench, this study investigates the variation in internal flow noise at the inlet and outlet monitoring points of a DN100 T-junction pipe under different flow velocities. Results indicate that with increasing flow velocity, both the sound pressure level and total sound pressure level at the inlet and outlet monitoring points increase. The highest total sound pressure level is observed at the vertical outlet monitoring point B, followed by the horizontal inlet monitoring point A, with the lowest at the horizontal outlet monitoring point C. At a constant flow velocity, the sound pressure level at the inlet and outlet points initially increases and then decreases as frequency increases.

Low Temperature Properties of Exchange-biased Magnetic Tunnel Junction

  • Lee, K. I.;J. G. Ha;S. Y. Bae;K. H. Shin
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.325-326
    • /
    • 2000
  • Low temperature diagnosis was performed as a probe for the integrity of MTJ(Magnetic tunnel junction) process which is optimised for the given plasma oxidation condition. TMR ratio increased slowly with decreasing temperature than that expected from spin wave exitation theory〔1〕. Junction resistance (RJ) does not follow T$\^$-$\frac{1}{2}$/ law below 200 K, indicating another conduction path besides spin polarized tunneling is involved at low temperature. Temperature dependence of conductance dip and bias dependence of TMR with temperature are discussed, from which the quality of tunnel barrier and its formation process can be inferred.

  • PDF

Junction, Circuit and System Developments for a High-$T_c$ Superconductor Sampler

  • Hidaka, M.;Satoh, T.;Tahara, S.
    • Progress in Superconductivity
    • /
    • v.1 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • A Josephson sampler circuit using high-Tc superconductor (HTS) ramp-edge junctions has been designed, fabricated, and experimentally tested. It consists of five ramp-edge junctions with a stacked groundplane and is based on single-flux-quantum (SFQ) operations. The sampler was used to measure current waveforms at picosecond and microampere resolutions. We are developing a system based on the sampler for measuring the current waveform in a room-temperature sample. And measuring current flowing through wiring in a semiconductor large-scale integrated circuit is a promising application for the HTS sampler system.

  • PDF

Numerical Study on the Droplet Flows in a Cross-Junction Channel Using the Lattice Boltzmann Method (Lattice Boltzmann 법을 이용한 Cross-Junction 채널 내의 droplet 유동에 관한 수치해석적 연구)

  • Park, Jae-Hyoun;Suh, Young-Kweon
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.407-410
    • /
    • 2006
  • This study describes a simulation of two-dimensional bubble forming and motion by the Lattice Boltzmann Method with the phase field equation. The free energy model is used to treat the interfacial force and deformation of binary fluids system, drawn into a T-junction the micro channel. A numerical simulation of a binary flow in a cross-junction channel is carried out by using the parallel computation method. The aim in this investigation is to examine the applicability of LBM to numerical analysis of binary fluid separation and motion in the micro channel.

  • PDF

Transport Properties of Ramp-Edge Junction with Columnar Defects (원통형 결함을 포함한 Ramp-Edge Junction의 수송특성)

  • Lee, C. W.;Kim, D. H.;Lee, T. W.;Sung, Gun-Yong;Kim, Sang-Hyeob
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.65-69
    • /
    • 2001
  • We measured the transport properties of$ YBa_2$$Cu_3$$O_{x}$ ramp-edge junction fabricated with interface-engineered barrier. The current-voltage characteristics show a typical resistively-shunted junction like behavior Voltage noise measurement revealed that the main source of the 1/f noise is the critical current and resistance fluctuations. The analysis of the noise data showed that the critical current fluctuations increase with temperature, whereas the resistance fluctuations are almost constant, and both fluctuations are almost correlated. The smaller magnitude of the critical current and resistance fluctuations seems to result from the columnar-deflects.s.

  • PDF

The Case Study on Thoraco-lumbar junction and Lumbo-sacral junction Transitional Zone Syndrome. (복합적으로 병발한 등-허리, 허리-엉치 이행부위 증후군에 대한 증례를 통한 고찰)

  • Hwang, Eun-Mi;Jung, Min-Gyu;Park, Young-Hoi;Keum, Dong-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.113-125
    • /
    • 2010
  • Objectives: We have evaluated the effects of conservative treatment on one patient who was diagnosed to thoraco-lumbar junction and lumbo-sacral junction transitional zone syndrome. so, we investigate thoraco-lumbar junction and Jumbo-sacral junction tranzitional zone syndrome that was suggested by Maigne R. Methods : One patient was diagnosed as T12-L1 herinated intervetebral disc through MRI. We diagnosed the patient to transitional zone syndrome by symptoms and physical examination and used Acupuncture therapy, Cox technique to the patient. We measured Visual Analog Scale(VAS) before and after treatment. Results: After treating Acupuncture therapy, Cox technique in the case, We find out that the patient was improved. VAS score changed from 7 to 2 and physical examinations are improved. Conclusions: We improved the patient who had thoraco-lumbar junction and lumbo-sacral junction transitional zone syndrome by Cox technique and Acupuncture therapy, and we found that thoraco-lumbar junction related lumbo-sacral junction.

  • PDF