• 제목/요약/키워드: T Equivalent Circuit

검색결과 111건 처리시간 0.025초

바닥난방 시스템의 열환경 개선을 위한 제어방안 연구 (A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System)

  • 송재엽;안병천;김경철;장사윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

전압방정식에서 시변성이 고려된 파라미터에 의한 토크 리플 산정 (The Estimation of Torque Ripple According to Parameters Considered Time-varying in Voltage Equation)

  • 김규화;조규원;김규탁
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1047-1052
    • /
    • 2017
  • In this paper, the calculation torque using the d-q axis has advantage like faster execution time. However, the torque ripple can't be considered in the torque calculation using d-q axis equivalent circuit because the time-dependent component is removed. When d-q transformation was performed, it was founded that some parameters has some characteristics. These characteristics were considered for representing torque ripple. The calculation with d-q axis transformation and Finite Element Analysis(FEA) were performed, and the results were compared. As a result, it was validated that the calculated torque can be expressed with ripple.

26GHz 대역 박막 Duplexer 설계에 관한 연구 (A Study on the Design of 26GHz Band Thin Duplexer)

  • 윤종남;이현주;오용부;이청운;김기돈;이정해
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2003년도 기술심포지움 논문집
    • /
    • pp.208-213
    • /
    • 2003
  • 본 논문에서는 mm대역에서 NRD를 사용하여 듀플렉스를 디자인하였다. 디자인된 듀플렉스는 두개의 단계적인 임피던스 필터와 T-junction으로 구성되어 있다. 단계적인 임피던스 필터는 무한 도파관의 등가회로모델과 리턴로스를 최소화하기 위해서 선택되어진 T-junction과 함께 디자인되었다. 듀플렉서의 특성은 기대되었던 결과와 함께 우수한 일치를 보여준다.

  • PDF

PV cell modeling의 수학적 고찰 (Mathematical Consideration on PV Cell Modeling)

  • 박현아;김효성
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2014
  • PV cell modeling is necessary both for software and hardware simulators in analyzing and testing the performance of PV generation systems. Unique I-V curve of a PV cell identifies its own characteristics by electrical equivalent model that is composed of diode constants ($I_o$, $v_t$), photo-generated current ($I_{ph}$), series resistance ($R_s$), and shunt resistance ($R_{sh}$). Photo-generated current can be easily estimated since it is proportional to irradiation level. However, other electrical parameters should be solved from the manufacturer's data sheet that is consisted with three remarkable operating points such as open circuit voltage ($V_{oc}$), short circuit current ($I_{sc}$), and maximum power voltage/current ($V_{MPP}/I_{MPP}$). This paper explains and analyzes mathematical process of a novel PV cell modeling algorithm that was proposed by the authors with the name of "K-algorithm".

직렬연결된 두 코일의 자기결합을 이용한 초전도 사고전류제한기의 사고전류제한 특성 컴퓨터 시뮬레이션 분석 (Computer Simulation Analysis on Fault Current Limiting Characteristics of SFCL using Magnetic Coupling of Two Coils with Series Connection)

  • 임성훈;안재민;김진석;문종필;김재철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.213-216
    • /
    • 2007
  • The computer simulation for the fault current limiting characteristics of the superconducting fault current limiter (SFCL) using the magnetic coupling of two coils was performed. The magnetic fluxes generated from two coils were canceled out during a normal time. However, the resistance generation of high-$T_c$ superconducting (HTSC) element after a fault occurrence keeps up the magnetic fluxes of two coils and contributes to the fault current limiting operation. Through the computer simulation for the fault current limiting characteristics based on its electrical equivalent circuit, its operational current and the limiting impedance could be improved by adjusting the inductance ratio between two coils.

  • PDF

준정상상태 해석을 통한 고정속 풍력 발전기의 FRT에 대한 STATCOM의 효과 분석 (Quasi-Steady-State Analysis on the Effect of the STATCOM on FRT Performance of Fixed Speed Wind Turbines)

  • 안선주;황평익;남순열;강상희;문승일
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.686-692
    • /
    • 2010
  • This paper analyzes the effect of the STATCOM on the improvement of the Fault Ride Through (FRT) capability of the fixed speed wind turbines(FSWTs). The steady-state models of the wind farm components, such as induction generator, capacitor bank, and the STATCOM, are developed based on the simplified equivalent circuit. Especially, the STATCOM is modeled as a controllable current source and a method that analytically determines the magnitude of the injection current is developed. For the quasi-steady-state(QSS) analysis, the steady-state model of the generator and STATCOM are merged with the dynamic model of drive train. The QSS simulation with the STATCOM shows that the STATCOM can enhance the FRT performance by improving the $W_r-T_e$ characteristics of the FSWTs.

인버터로 구동되는 대용량 LIM의 정특성 시험과 동특성 해석 (The Analysis on Dynamic Characteristics and the Static test of Inverter-fed Large capacity LIM)

  • 장석명;이현구;정상섭;박영태;김봉섭;정현갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.213-215
    • /
    • 1996
  • Until now the test of LIM have been mainly experimented for a small capacity LIM. This paper deals with the static characteristics of a large capacity LIM which is designed for MAGLEV. And we developed the simulation program using electro-magnetic field theory and equivalent circuit method. Hence it is evaluated the performance of a large capacity LIM. Also this paper predicts the dynamic characteristics of LIM with the proposed simulation program.

  • PDF

Fault Current Limiting Characteristics of Separated and Integrated Three-Phase Flux-Lock Type SFCLs

  • Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.289-293
    • /
    • 2007
  • The fault current limiting characteristics of the separated and the integrated three-phase flux-lock type superconducting fault current limiters (SFCLs) were analyzed. The three-phase flux-lock type SFCL consisted of three flux-lock reactors and three $high-T_c$ superconducting (HTSC) elements. In the integrated three-phase flux-lock type SFCL, three flux-lock reactors are connected on the same iron core. On the other hand, three flux-lock reactors of the separated three-phase flux-lock type SFCL are connected on three separated iron cores. The integrated three-phase flux-lock type SFCL showed the different fault current limiting characteristics from the separated three-phase flux-lock type SFCL that the fault phase could affect the sound phase, which resulted in quench of the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the separated and the integrated three-phase flux-lock type SFCLs according to the ground fault types were compared.

600W급 IPMSM의 고정자 설계 변수 변화에 따른 온도 특성 분석 및 고찰 (Analysis of IPMSM Temperature Characteristics based on Stator Design Parameters)

  • 고덕화;김용태;김규탁
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1201-1206
    • /
    • 2017
  • In this paper, the temperature characteristics by change the width of teeth and yoke in the stat or parameters were analyzed. An initial model of fill factor 45 [%] was produced. Through the experiment, the validity of the temperature analysis using the thermal equivalent circuit method was verified. So, initial model was selected as basic model. Also, temperature characteristic analysis was performed for each width change of the stator teeth and yoke, and the effects of the width of stator teeth and yoke on the temperature characteristics were analyzed.

X-Band용 HBT의 전력 특성에 관한 연구 (Power Performance of X-Band Heterojunction Bipolar Transistors)

  • 이제희;김연태;송재복;원태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.158-162
    • /
    • 1995
  • We report rf and power characteristics of AlGaAs/GaAs Heterojunction Bipolar Transistor (HBTs) for X-band power applications. HBTs have been fabricated with polyimide a an interlayer dielectric. By characterizing the DC and RF characteristics we obtained the maximum current gain of 45, BV$\_$CEO/ of 10 V, fT of 30 GHz and f$\_$max/ of 17 GHz for device with 6x14$\mu\textrm{m}$$^2$emitter size. To extract accurate equivalent parameters, the De-embedded method was applied for extraction of parasitic parameters and the calculation of circuit equations for intrinsic parameters. Based on the Load-pull method, power characteristics was simulated and measured to get the maximum output power of the device.

  • PDF