A Study on the Parameters and Characteristic of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • 전내석;김종윤;오진석;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.497-504
    • /
    • 2000
  • This paper presents a method for the equivalent-circuit parameters and torque characteristics calculation of squirrel-cage induction motors. The measurment of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test through T type equivalent-circuit method. Especially, this paper describes the test results obtained by using hall sensor and strain gage for the current and the torque characteristics of induction motors. 1(HP), three-phase squirrel cage induction motor has been used during the test and the parameters are compared with those obtained by the maker parameters of simulation results and experiment.

  • PDF

A design of the annular induction electromagnetic pump by equivalent circuit modelling (등가회로 해석법에 의한 환단면형 유도전자펌프의 설계)

  • Kim, H.R.;Hong, S.H.;Hwang, J.S.;Min, B.T.;Nam, H.Y.;Cho, M.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

A Study on the Parameters and Characteristics of Induction Motor driven by Inverter (인버터로 구동되는 유도전동기의 정수 및 특성에 관한 연구)

  • Jeon, Nae-Suck;Kim, Jong-Yun;Park, Chan-Kun;Eum, Sang-O;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1111-1113
    • /
    • 2000
  • This paper presents the calculation method for the equivalent-circuit parameters and torque characteristics of squirrel-cage induction motors. The measurement of motor parameters were calculated by the stator resistance test, the blocked rotor test and no load test to T type equivalent-circuit. Especially, this paper describes the test results obtained by using hall sensor and strain gauge for the current and torque characteristics of induction motors. Three-phase squirrel-cage induction motor which has 1[hp] was used to the test and the parameters obtained by the test were compared with the maker parameters.

  • PDF

Neutral Current Calculation of Pole-Top Overhead Distribution Line (가공 배전선로 장주의 중성선 전류 계산)

  • Seo, Hun-Chul;Kwon, O-Sang;Kim, Chul-Hwan;Jung, Chang-Soo;Yoo, Yeon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.

Analysis of Distributed Airgap Magnetic Density for Induction Motor using Magnetic Equivalent Circuit (자기등가회로법에 의한 유도전동기의 공극자속밀도 분포해석)

  • Jeong, J.H.;Lee, E.W.;Sohn, H.K.;Koo, T.M.;Lim, S.S.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.65-67
    • /
    • 2001
  • In general, the results of finite element method(FEM) on the analysis of the electrical machines has known as high accuracy but required very long time to calculate the field distribution. Magnetic equivalent circuit(MEC) method can be computing times less than the finite element method and also it provides steady state and transient state simulation. In this paper, describes matrix representation of the winding magneto motive force(MMF) and carry out the distributed the airgap magnetic density takes into account the influence on the stator slots.

  • PDF

Nonlinear Analysis of Hybrid Stepping Motor using 3D Equivalent Magnetic Circuit Network Method (3차원 등가자기회로방법을 이용한 하이브리드 스태핑 모터의 비선형 해석)

  • Jin, C.S.;Kim, S.;Lee, J.;Kim, Y.T.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.131-133
    • /
    • 2001
  • 2D analysis is impossible for Hybrid stepping motor(HSM) and 3D analysis is necessary because the permanent magnet is magnetized to the axial direction. In this paper, the characteristics of HSM are analyzed by using 3D equivalent magnetic circuit network method(3D EMCNM). In addition, the trapezoidal element is introduced for the exact permeance calculation in the complex shape machinery such as HSM. The magnetic saturation of core is considered.

  • PDF

A Study on Characteristics and Equivalent Circuit Model of Underwater Wireless Power Transfer System by Salinity (염도에 따른 수중 무선전력전송 시스템 특성 및 등가모델 연구)

  • Lee, Jeong-Geon;Kang, Wonshil;Ku, Hyunchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.851-856
    • /
    • 2018
  • In this study, we analyze the characteristics of wireless power transfer(WPT) based on magnetic resonance in an underwater environment and propose an equivalent model suitable for underwater WPT. The proposed underwater WPT equivalent model is constructed by expanding the free-space WPT T-model reflecting characteristics change according to media. Considering the water salinity, we propose a method to extract the parameters of the proposed model based on the S parameters. To verify the proposed model, a 6.78-MHz underwater WPT system was constructed and compared with the predicted power transfer efficiency of the model. As a result, it was confirmed that the proposed model predicts the variation of characteristics with an average error of less than 3 %.

A 3 ~ 5 GHz CMOS UWB Radar Chip for Surveillance and Biometric Applications

  • Lee, Seung-Jun;Ha, Jong-Ok;Jung, Seung-Hwan;Yoo, Hyun-Jin;Chun, Young-Hoon;Kim, Wan-Sik;Lee, Noh-Bok;Eo, Yun-Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.4
    • /
    • pp.238-246
    • /
    • 2011
  • A 3-5 GHz UWB radar chip in 0.13 ${\mu}m$ CMOS process is presented in this paper. The UWB radar transceiver for surveillance and biometric applications adopts the equivalent time sampling architecture and 4-channel time interleaved samplers to relax the impractical sampling frequency and enhance the overall scanning time. The RF front end (RFFE) includes the wideband LNA and 4-way RF power splitter, and the analog signal processing part consists of the high speed track & hold (T&H) / sample & hold (S&H) and integrator. The interleaved timing clocks are generated using a delay locked loop. The UWB transmitter employs the digitally synthesized topology. The measured NF of RFFE is 9.5 dB in 3-5 GHz. And DLL timing resolution is 50 ps. The measured spectrum of UWB transmitter shows the center frequency within 3-5 GHz satisfying the FCC spectrum mask. The power consumption of receiver and transmitter are 106.5 mW and 57 mW at 1.5 V supply, respectively.

Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

Analysis on Operational Current and Current Distribution between Two Coils of flux-lock Type SFCL (자속구속형 고온초전도 전류제한기의 동작전류와 각 코일의 전류분류 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Hyo-Sang;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.753-758
    • /
    • 2005
  • A flux-lock type superconducting fault current limiter(SFCL) consists of two coils, which are wound in parallel each other through an iron core, and a high-$T_c$ Superconducting(HTSC) thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance of the HTSC thin film generated, and thereby the fault current can be limited by the impedance of the fluk-lock type SFCL. In this paper, we investigated the dependence of both the fault current limiting characteristics and the current distribution between two coils on the operational current of the flux-lock type SFCL through the equivalent circuit analyses and short circuit tests. From the comparison of both the results, the experimental results well agreed with the analyses for equivalent circuit.