• 제목/요약/키워드: T/N ratio

검색결과 1,175건 처리시간 0.033초

상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향 (The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment)

  • 신명철;이영신
    • 한국환경보건학회지
    • /
    • 제35권1호
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

Clinical significance of the lymph node ratio in N1 breast cancer

  • Kim, Jaeho;Kim, Jin Hee;Kim, Ok Bae;Oh, Young Kee;Park, Seung Gyu
    • Radiation Oncology Journal
    • /
    • 제35권3호
    • /
    • pp.227-232
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the prognostic value of the lymph node ratio (LNR), which was defined as the proportion of involved nodes of all dissected nodes, in pN1 breast cancer. Materials and Methods: We retrospectively analyzed the clinical data of patients with pN1 breast cancer (n = 144) treated at Keimyung University Dongsan Medical Center, Daegu, Korea between 2001 and 2010. The median age was 46 years (range, 27 to 66 years). The LNR was 0.01-0.15 (low LNR) in 130 patients and >0.15 (high LNR) in 14 patients. Sixty-five patients (45.1%) had T1 tumors, 74 (51.4%) had T2 tumors, and 5 (3.5%) had T3 tumors. Eighty-eight patients (61.1%) underwent total mastectomy and 56 (38.9%) underwent partial mastectomy. Fifty-nine patients (41.0%) underwent radiotherapy and 12 (8.3%) underwent regional radiotherapy. The median follow-up period was 65 months. Results: The 5- and 10-year disease-free survival (DFS) rates were 92.7% and 82.4%, respectively. Univariate analyses revealed that high LNR (p = 0.004), total mastectomy (p = 0.006), no local radiotherapy (p = 0.036), and stage T2 or T3 (p = 0.010) were associated with worse DFS. In multivariable analysis, only high LNR (p = 0.015) was associated with worse DFS. Conclusion: High LNR is an independent prognostic factor in pN1 breast cancer and could be an indication for adjuvant radiotherapy in these patients.

격벽에 의한 조분리와 내부반송을 이용한 산화구 시설의 고도처리개선에 관한 연구 (A Study on the Treatment of Nutrients and Organic Carbon in Wastewater through Spatial Separation and Internal Recycling in a Modified Oxidation Ditch)

  • 이영신;오대민
    • 한국환경보건학회지
    • /
    • 제37권1호
    • /
    • pp.64-72
    • /
    • 2011
  • This study was performed to assess the removal efficiency on nitrogen, phosphorus and organic carbon in wastewater by spatial separation and internal recycling in a modified oxidation ditch process (modified OD). The performances of the modified OD were evaluated via laboratory-scale experiments. The process was operated at hydraulic retention times of 6-48 hours and solid retention times of 17-38 days. We found that organic carbon removal efficiency increased after the modified OD operation period. T-N removal efficiency remained stable; average T-N concentration of effluent was 8.02 mg/l after modified OD operation. In contrast, T-P concentration of effluent was over 1 mg/l. Nitrogen and phosphorus removal efficiency of modified OD at HRT 12 hr were 83.1% and 74.1%, respectively. Also, maximum efficiency was found at SRTs from 20 to 30 days. T-N removal efficiency was 83.1% at a C/N ratio from 3.0 to 3.5. However, T-N removal efficiency decreased at C/N ratios over 3.5. Also, T-P removal efficiency increased with HRT at C/P ratios in the same condition. Maximum efficiency was 74.1% at a C/P ratio from 25 to 28. T-N removal efficiency was 79.2% and T-P removal efficiency was 65.3% after M4 mode operation (added to the internal recycle line connected to the anoxic reactor). The modified OD with spatial separation and internal recycling developed in this study is, therefore, believed to be an improvement for solving problems in the nutrient removal technologies.

Characterization of focal hepatic lesions with ferucarbotran (Resovist)-enhanced T2 and T2*-weighted MR imaging

  • 조은석;유정식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.40-40
    • /
    • 2003
  • The purpose of this study was to characterize focal hepatic lesions through pre and post ferucarbotran-enhanced T2 and T2*-weighted imaging and to help differentiate benign and malignant lesions 대상 및 방법: Consecutive 34 patients with 52 hepatic lesions underwent MRI before and after intravenous bolus injection of ferucarbotran (Resovist Sobering, Berlin, Germany) for evaluation of focal hepatic lesions. Lesions included hemangiomas (n=17), metastases (n=12), cysts (n=10), hepatocellular carcinomas (n=8), dysplastic nodules (n=4), and focal fat deposit (n=1). T2-weighted fast spin echo (TR/TE: 4060/138) and gradient echo T2*-weighted images(TR/TE: 140/5.3, FA = 90) were obtained according to the institutional routine imaging protocol. Lesional signal-intensity and lesion-to-liver contrast changes were measured by contrast-to-noise ratio (CNR) from region of interest.

  • PDF

T-N 제거공정 개선을 위한 하수처리장 공정 분석 (Analysis of sewage treatment process for the improvement of T-N removal process)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제27권2호
    • /
    • pp.99-107
    • /
    • 2018
  • In order to design the improvement process for T-N removal, the treatment process of Suyoung, Gangbyeon, and Noxan sewage treatment plants (STP) in Busan was anlayzed. Suyoung STP shows a T-N removal efficiency of about 69.8% with MLE(Modified Ludzack ettinger) and A2O+MBR. However, it is necessary to improve the process to maintain over DO of 1 mg/L and is required to install a flow control tank to minimize the rainfall effect. Gangbyun STP shows a about 70.2% T-N removal efficiency with A2O+GFF(gravity fiber filtration). However, in order to improve T-N removal efficiency, it is needed to install MLE process to treat recycle water. Noksan STP shows a T-N removal efficiency of about 71.0% with MLE+Chemical treatment and shows stable T-N concentration in effluent. However, it is required a toxic chemical management process because bad wastewater flows into the STP, also is necessary a process improvement in order to increase internal recycling ratio. Especially, it is required a process improvement to increase HRT of nitrification tank because Suyoung and Gangbyeon STPs shows low nitrification efficiency during winter season.

저온 감열 특성을 가지는 Comb-Type Grafted Polymer Hydrogels의 합성 및 특성평가 (Synthesis and Characterization of Comb-Type Grafted Polymer Hydrogels with Low Temperature Sensitivity)

  • 정택규;김승수;신병철
    • 대한화학회지
    • /
    • 제47권1호
    • /
    • pp.59-66
    • /
    • 2003
  • 생물학적 의약품, 식품 등과 같이 저온 유통 체계(cold chain)를 관리하는데 있어서 제품 용기에 부착하여 보관 온도 이상에 노출될 경우 비가역적인 변화를 일으켜 고온 노출여부를 검지 할 수 있는 라벨의 소재로소 poly(N-isopropylacrylamide-co-t-butylacrylamide) [p(NIPAAm-co-t-BAM)]수화겔의 적용 가능성을 평가하였다. p(NIPAAm-co-t-BAM)수화겔은 cold chain 온도인 8$^{\circ}$C 이하에서 온도 민감성을 갖도록 t-BAM양을 조절하여 레독스 중합반응을 통하여 저온 (4$^{\circ}$C)합성하였고, 또한 oli해(NIPAAm-co-t-BAM) 공중합체를 그라프트하여 빗살 구조를 가지는 가교수화겔을 제조함으로써 수화겔의 수축 팽윤 속도를 향상시키고자 하였다. 합성 된 수화겔의 lower critical solution temperatures(LCSTs)는 흐림 점 측정법과 시차주사열량계(DSC)를 이용하여 측정하였으며, NIPAAm 단량체와 빗살형태의 t-BAM 공중합체의 조성비가 가교제의 양에 따라 수화겔의 수축과 팽윤 거동을 관찰하였다. 소수성기를 포함하는 t-BAM의 조성비율에 따라 8$^{\circ}$C 이하 저온에서 수화겔의 LCST조절이 가능하며, 빗살 형태로 그라프트된 공중합체의 조성비에 따라 수축-팽윤율 및 속도의 조절이 가능한 것으로 확인되었다.

양성자 자기회전비율 측정을 위한 지자장 상쇄장치 제작 (Construction of an Earth's Field Compensation System for the Mcasurement of. Proton Gyromagnetic Ratio)

  • 우병칠;박포규;김철기;유권상;김창석
    • 한국자기학회지
    • /
    • 제2권2호
    • /
    • pp.156-162
    • /
    • 1992
  • 저자장방법으로 양성자 자기회전비율을 측정할 때, 지자장을 상쇄시켜 무자장 실험공간을 형성시킬 필요가 있다. 이를 위해 일정한 자장성분은 헬름홀쯔코일에 흐르는 정전류에 의하여 상쇄 되고, 미소변화 자장은 폐회로를 구성하는 궤환장치에 의해 자동적으로 상쇄되는 지자장 상쇄장치 를 설계하였다. 지자장성분을 상쇄하기 위해 코일상수가 같은 대형 및 소형 3축 헬름홀쯔코일과 미 소변화 자장 상쇄용 궤환증폭기를 제작하였다. 제작된 시스템을 사용하여 일반실험실 내에서 예비 실험을 한 결과 수십 ${\mu}T$ 의 일정한 자장성분과 ${\pm}100nT$ 의 미소변화 자장을 상쇄하여 잔류자 장이 ${\pm}10nT$ 이하인 공간을 형성하였다.

  • PDF

WASP7 모형을 이용한 임하호 수질모의에 관한 연구 (The Research about the Water Quality Prediction at Imha Reservoir Using a WASP7 Model)

  • 안승섭;서명준;정도준;박노삼
    • 한국환경과학회지
    • /
    • 제17권6호
    • /
    • pp.611-621
    • /
    • 2008
  • This study intends to provide the necessary basic data needed for predicting the water quality and examining changes in water quality on the basis of the hydrological changes: an outflow or the character of a flow by investigating the interaction of the parameters through the estimation of optimal parameters need for predicting the water quality of the dam basin and the sensitivity among those estimated parameters. Im-Ha Dam in the upstream area of the Nakdong River was selected for analysis, and the water quality survey data necessary for parameter estimation was based on the monthly water quality data (water temperature, BOD, T-N and T-P) between December 1, $2005{\sim}$November 31, 2006. K1C(the saturated growth rate of plant plankton), K1RC (endogenous respiratory quotient of plankton), KDC(deoxidized ratio), K71C(minealized ratio of dissolved organic phosphorus), K83C(mineralized ratio of dissolved organic nitrogen) have been considered as the factors of the water quality performed in this water quality simulation, that is, the most effective parameters on BOD, T-N and T-P. In the result of the analysis of the sensitivity, KDC(deoxidized ratio) was the most sensitively reacted parameter on BOD and it was K71C(mineralized ratio of dissolved organic phosphorus) and K83C(mineralized ratio of dissolved organic nitrogen) on T-N and T-P. It is considered that it will be possible to apply the most optimal parameter to an analysis of the water quality simulation at Im-Ha Ho basin in the goal year by examining the interaction of the parameters through the parameters sampling which are able to applicable to prediction of the water quality and the analysis of the its sensitivity, in the future, also the analysis on the basis of the hydrological conditions: an outflow or the character of a flow will be needed.

다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거 (Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio)

  • 최규철;윤용수;정일현
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발 (Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage)

  • 정진우;김성원;津野洋
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.