Study of Hot Salt Stress Corrosion Crack Initiation of Alloy IMI 834 by using DC Potential Drop Method

  • Pustode, Mangesh D.;Dewangan, Bhupendra;Raja, V.S.;Paulose, Neeta;Babu, Narendra
    • Corrosion Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.203-208
    • /
    • 2016
  • DC potential drop technique was employed during the slow strain rate tests to study the hot salt stress corrosion crack (HSSCC) initiation at 300 and $400^{\circ}C$. Threshold stresses for HSSCC initiation were found to about 88 % of the yield strength at both temperatures, but the time from crack initiation to final failure (${\Delta}t_{scc}$) decreased significantly with temperature, which reflects larger tendency for brittle fracture and secondary cracking. The brittle fracture features consisted of transgranular cracking through the primary ${\alpha}$ grain and discontinuous faceted cracking through the transformed ${\beta}$ grains.

Improvement of output voltage drop characteristic for 3-phase voltage disturbance generator (3상 전압변동 발생기의 출력전압강하 특성 개선)

  • Lee, Y.H.;Min, B.H.;Park, S.D.;Nho, E.C.;Kim, I.D.;Chum, T.W.;Kim, H.G.;Choi, N.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.120-122
    • /
    • 2007
  • A new power quality disturbance generator is proposed. The proposed scheme overcomes the problem of voltage drop of the conventional generator in normal mode. Therefore, the output voltage of the proposed generator is constant in normal mode and the efficiency of the series transformer is improved. The proposed generator has good feature of simple structure, cost effective implementation, high reliability and easy control. The usefulness of the scheme is verified through simulation and experiments.

  • PDF

Study on Performance Test of Plate Type ER-Valves (평판형 ER-Valve의 성능실험에 관한 연구)

  • Jang S.C.;Yum M.O.;Kim D.T.;Park J.B.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.321-324
    • /
    • 2002
  • Hydraulic valve control the pressure and the How of fluid by the hydraulic oil transfered from pump but the ER fluid consists of solid particles of micrometer in size and insulating oil so in the general hydraulic valve. We invented ER-Valve using ER fluid as working fluid. The ER fluid, working fluid of ER-Valve is a functional fluid to represent the feature of fluid according to strength of electric field. In this research we made our own 4 types of plate type ER-Valve which has same surface but different width and length and then we conducted performance test. We measured flow rate and pressure drop of fluid which is flowing in the ER-Valve according to the electric field strength to conduct this test. We modeling ER-Valve relating to ER-Valve system and yield shear stress according to the strength of electric field. We used the pressure drop according to the strength of electric field by differential pressure gauge in the our own made ER-Valve. This test reviewed experimental the special changes of ER-Fluid in the steady flow condition.

  • PDF

Feasibility of UHPC shields in spent fuel vertical concrete cask to resist accidental drop impact

  • P.C. Jia;H. Wu;L.L. Ma;Q. Peng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4146-4158
    • /
    • 2022
  • Ultra-high performance concrete (UHPC) has been widely utilized in military and civil protective structures to resist intensive loadings attributed to its excellent properties, e.g., high tensile/compressive strength, high dynamic toughness and impact resistance. At present, aiming to improve the defects of the traditional vertical concrete cask (VCC), i.e., the external storage facility of spent fuel, with normal strength concrete (NSC) shield, e.g., heavy weight and difficult to fabricate/transform, the feasibility of UHPC applied in the shield of VCC is numerically examined considering its high radiation and corrosion resistance. Firstly, the finite element (FE) analyses approach and material model parameters of NSC and UHPC are verified based on the 1/3 scaled VCC tip-over test and drop hammer test on UHPC members, respectively. Then, the refined FE model of prototypical VCC is established and utilized to examine its dynamic behaviors and damage distribution in accidental tip-over and end-drop events, in which the various influential factors, e.g., UHPC shield thickness, concrete ground thickness, and sealing methods of steel container are considered. In conclusion, by quantitatively evaluating the safety of VCC in terms of the shield damage and vibrations, it is found that adopting the 300 mm-thick UHPC shield instead of the conventional 650 mm-thick NSC shield can reduce about 1/3 of the total weight of VCC, i.e., about 50 t, and 37% floor space, as well as guarantee the structural integrity of VCC during the accidental drop simultaneously. Besides, based on the parametric analyses, the thickness of concrete ground in the VCC storage site is recommended as less than 500 mm, and the welded connection is recommended for the sealing method of steel containers.

Effect of transverse compressive stress on $I_{c}$ degradation characteristics in Bi-2223 superconducting tapes (Bi-2223 초전도테이프의 임계전류 열화특성에 미치는 횡방향 압축응력의 영향)

  • 신형섭;김병수;오상수;하동우;하홍수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.101-104
    • /
    • 2003
  • Influences of transverse compressive stress on the critical current ( $I_{c}$) in AgMg and AgMn alloy sheathed Bi-2223 tapes were investigated at 77 K and 0 T. The $I_{c}$ degradation behavior depending on sample specifications was discussed in viewpoints of n-value and damage morphology. As a result, Bi-2223 tapes showed a significant drop in $I_{c}$ for stresses greater than 50MPa. The AgMg sheathed Bi-2223 tapes representing higher $I_{c}$ showed a lower $\sigma$$_{irr}$ and a significant $I_{c}$ degradation with increase in compressive stress. There existed a voltage tap separation dependency of the $I_{c}$ degradation behavior caused by the transverse compressive stress.sive stress.s.

  • PDF

A Study on Corrosion Fatigue Crack Growth Behavior in Al-Alloy 7075-T651 (I) (Al-Alloy 7075-T651의 부식피로균열 성장거동에 관한 연구(I))

  • 김봉철;한지원;우흥식
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 1998
  • Fatigue crack growth rates(i.e. crack initiation and crack growth of short and long crack) are investigated using commercial plates of high strength Al alloy 7075-T651 for the transverse-longitudinal(T-L) direction in air, water and sea water. Also, the evaluation direct current potential drop(D.C.P.D) method and the fractographical analysis by SEM are carried out. Near threshold region, short crack growth rates were much faster than those of comparable long cracks, and these short crack growth rates actually decrease with increasing crack growth and eventually merge with long crack data. Fatigue crack propagation rates in aggressive media(i.e. sea water) increase noticeably over three times those in air. One of the most significant characters in this phenomenon as a corrosion-fatigue causes an acceleration in crack growth rates. Sea water environment, particularly Cl$^{[-10]}$ solution brings the most detrimental effects to aluminum alloy. The result of fractographical morphology in air, water and sea water by SEM shows obvious dimpled rupture and typical striation in air, but transgranular fracture surface in water and sea water.

  • PDF

Electrical Properties of $C_{22}$-Quinolium(TCNQ) Langmuir-Blodgett Films Depending on the Frequency ($C_{22}$-Quinolium(TCNQ) LB 막의 주파수에 따른 전기적 특성)

  • Lee, S.K.;You, D.S.;Kim, T.W.;Kim, Y.K.;Kwon, Y.S.;Kang, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1289-1291
    • /
    • 1994
  • Dielectric properties of $C_{22}$-Quinolium(TCNQ) Langmuir-Blodgett (LB) films were studied as a function of frequency(10Hz-13MHz) and annealing temperature($20{\sim}240^{\circ}C$). A complex dielectric constant ${\epsilon}^*={\epsilon}'-i{\epsilon}"$, in general, shows the frequency dependence of orientational polarization in the measured frequency range. A dielectric permittivity ${\epsilon}'$ at 10Hz is around 8.2 and decreases very slowly as the frequency increases up to 1 MHz, and then suddenly drops above this frequency, while a dielectric loss factor ${\epsilon}"$ reaches a maximum near 1 MHz. Its annealing temperature dependence at 10Hz shows that ${\epsilon}'$ and ${\epsilon}"$ increase as the temperature increases upto $180^{\circ}C$, even though there is a little drop near $120{\sim}160^{\circ}C$. Both ${\epsilon}'$ and ${\epsilon}"$ drop quickly above $180^{\circ}C$. which may be thought of a destruction of the LB films. Another fact of the annealing temperature dependence of the dielectric constant is an occurrence of the new dielectric dispersion below 100Hz. This low frequency dispersion is getting clear above $80^{\circ}C$.

  • PDF

The Transient Response of CF$_4$ RF Plasmas Using One-dimensional Fluid Model (1차원 유체모델을 이용한 CF$_4$ RF 플라즈마의 과도응답 특성)

  • 소순열;임장섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • $CF_4$ gas is one of the most useful gases in modern technologies for semiconductor fabrication. However, there are many problems which should be solved in order to fabricate semiconductor device, for example, etching speed drop due to ion charge-up and etching selectivity drop due to the high electron energy. One of useful method in order to suppress their damages above is pulsed-time modulated plasma (PM). However, transient responses of charged particles occur when the source power is turned-on and -off in PM method. To control plasma properties in detail, such a transient phenomenon must be investigated. In this paper, we investigate $CF_4$ RF plasma properties under a one-dimensional fluid model. And also for dynamic and stable control of $CF_4$ plasmas, we investigated the transient behavior of the plasmas after step up or down of the amplitude of the power source voltage $V_s$(t). Fundamental properties of transient $CF_4$ plasmas was discussed. Furthermore, we intend to discuss new method for pulsed-time plasma modulation.

Multidrop Ethernet based IoT Architecture Design for VLBI System Control and Monitor (VLBI 시스템 제어 및 모니터를 위한 멀티드롭 이더넷 기반 IoT 아키텍처 설계)

  • Song, Min-Gyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1159-1168
    • /
    • 2020
  • In the past, control and monitor of a large number of instruments is a specialized area, which requires an expensive dedicated module to implement. However, with the recent development of embedded technology, various products capable of performing M&C (Monitor and Control) have been released, and the scope of application is expanding. Accordingly, it is possible to more easily build a small M&C environment than before. In this paper, we discussed a method to replace the M&C of the VLBI system, which had to be implemented through a specialized hardware product, with an inexpensive general imbeded technology. Memory based data transmission, reception and storage is a technology that is already generalized not only in VLBI but also in the network field, and more effective M&C can be implemented when some items of Ethernet are optimized for the VLBI (Very Long Baseline Interferometer) system environment. In this paper, we discuss in depth the design and implementation for the multidrop based IoT architecture.

A Clinical Measure of the Skin to Cervical Epidural Space Depth in the Korean Adults (한국 성인의 피부에서 경부 경막외강까지의 깊이)

  • Han, Kyung-Ream;Choi, Hee-Roung;Hyun, Hye-Shin;Kwak, No-Kil;Kim, Chan
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.114-118
    • /
    • 1999
  • Backgrouds: Cervical epidural blocks were used as part of a comprehensive multimodal treatment program for patients with chronic pain in the head, neck and upper extremities. The depth of the epidural space beneth the skin surface varies at different levels of the spinal column in the same patient. It also varies from patient to patient at the same vertebral level. We studied the distance the skin to the cervical epidural space in adults patients at different intervertebral spaces. Methods: Date were gathered from 628 patients having cervical epidural block for relief of cervical and upper extrimity pain. All blocks were performed using hanging drop method after loss of resistance with saline at C5-6, C6-7, C7-T1 intervertebral space. Results: Mean distances for skin to cervical epidural space (DSES) were 5.42 cm, 5.06 cm, 4.68 cm in male, 5.00 cm, 4.61 cm, 4.10 cm in female at C7-T1, C6-7, C5-6 intervertebral space. DSES correlated with body weight, neck circumference and body mass index significantly. Conclusion: In the cervical spine, DSES varies from space to space. The longest DSES were noted at C7-T1 level in male, and the shortest DSES were at C5-6 in female. DSES has significant relationships with weight, neck circumference and body mass index.

  • PDF