• Title/Summary/Keyword: Systolic blood measurement

Search Result 151, Processing Time 0.025 seconds

The Antihypertensive Effect of Gyeok pal sang saeng yeok chim Acupuncture Treatment in Hypertension Patients (고혈압 환자에서 격팔상생역침범(隔八相生易鐵法)의 혈압강하 효과)

  • Han, Chang-Hyun;Han, Choong-Hee;Shin, Mi-Suk;Shin, Seon-Hwa;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.49-60
    • /
    • 2006
  • Objectives : The aim of the study was to investigate the antihypertensive effect of Gyeok pal sang saeng Yeok chim Acupuncture in hypertensive patients. Methods : We measured the blood pressure of the patients who were admitted in the Oriental Medical Clinic of Brother from 13th February 2006 to 13th May 2006. We included the patients only in case of the systolic blood pressure was over 120mmHg or diastolic blood pressure was over 80mmHg, thirty patients were treated by Gyeok pal sang saeng Yeok chim Acupuncture. In order to evaluate the effect of the Gyeok pal sang saeng Yeok chim Acupuncture, the blood pressure and pulse rate were measured before and after Acupuncture procedure total 10 times. Results : There were significant decrease in the systolic blood pressure and significant decrease in the diastolic blood pressure treated by Gyeok pal sang saeng Yeok chim Acupuncture 10 times but pulse rate was not significantly decreased. The effect of Gyeok pal sang saeng Yeok chim Acupuncture by measurement time on blood pressure were follows: In a systolic blood pressure and diastolic blood pressure was gradually deceased significantly from 1st to 10th but pulse rate was not significantly decreased. Conclusion : These results suggest that Gyeok pal sang saeng Yeok chim Acupuncture is effective in decreasing the systolic and diastolic blood pressure.

  • PDF

Effectiveness of Hwang-gu acupuncture treatment in hypertension patients; case report (황구침법(黃丘鍼法)을 이용한 고혈압 환자의 혈압강하 효과에 대한 증례보고)

  • Han, Chang-Hyun;Hwang, Chi-Won;Shin, Mi-Suk;Shin, Seon-Hwa;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.23 no.3
    • /
    • pp.37-50
    • /
    • 2006
  • Objectives : The aim of the study was to investigate the antihypertensive effect of Hwang-gu Acupuncture in hypertensive patients. Methods : We measured the blood pressure of the patients who were admitted in the Oriental Medical Clinic of Brother from 25th November 2005 to 27th March 2006. We included the patients only in case of the systolic blood pressure was over 140mmHg or diastolic blood pressure was over 90mmHg, Twenty two patients were treated by Hwang-gu Acupuncture. In order to evaluate the effect of the Hwang-gu Acupuncture, the blood pressure was measured before and after Acupuncture procedure total 4 times, 10times. Results : There were a significant decrease in the systolic blood pressure and significant decrease in the diastolic blood pressure by Hwang-gu Acupuncture 4 times. The effect of Hwang-gu Acupuncture by measurement time on blood pressure were follows: In a systolic blood pressure was gradually deceased significantly from 1st to 4th but diastolic blood pressure was significantly decreased after 2nd and 4th only. Conclusions : These results suggest that Hwang-gu Acupuncture is effective in decreasing the systolic and diastolic blood pressure.

  • PDF

Evluation of the DINAMAP 8100 Automated Blood Pressure monitor ; comparison with the Mercury Sphygmomanometer (수은 혈압계와 DINAMAP 8100 자동 혈압계의 혈압측정치 비교연구)

  • Kim Mee-Yeon;Choi Hee-Kang;Kim Nam-Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.1
    • /
    • pp.96-107
    • /
    • 1996
  • Automated blood pressure monitors have gained acceptance in many clinical settings with the increasing demand, the accurate BP measuring devices reguire the need for validation. We have evaluated the Dinamap 8100, an oscillometric automated blood pressure monitor, using the Mercury sphygmomanometer as a reference. Comparison of sphygmomanometers was conducted 60 patients (30-Normotensive group, 30-Hypertensive group at Seoul National University Hospital. Two trained observers took measure blood pressure(systolic/diastolic) at the same time using the Dinamap 8100 on one arm and the Mercury on the other. For each measurement, the device was randomly selected from a group of devices repetively used for the experiment. Mean readings for systolic pressure with the Dinamap 8100 in normotensive group were lower(mean difference ; 4.26mmHg) than the Mercury type. Mean readings for systolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.05mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in normotensive group were lower (mean difference ; 7.46mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.03mmHg) than the Mercury type. We have found that blood pressure readings with the Dinamap 8100 were lower than those with the Mercury type. we are using the Mercury type in clinics, although it has observer bias and terminal digit preference. But the Dinamap 8100 is readily portable, simple to use, and capable of preventing observer bias and terminal digit preference. The Dinamap 8100 is acceptable for blood pressure determination in subjects who are normotensive or hypertensive ones.

  • PDF

Analysis of the Convergence Algorithm Model for Estimating Systolic and Diastolic Blood Pressure Based on Two Photoplethysmography (두 개의 광전용적맥파 기반의 수축기 혈압과 이완기 혈압 추정 융합 알고리즘 모델 분석)

  • Kim, Seon-Chil;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.8
    • /
    • pp.53-58
    • /
    • 2019
  • Recently, product research has been continuously conducted to enhance accessibility to blood pressure measurement for the purpose of healthcare for the chronic patient. In previous studies, electrocardiogram (ECG) and photoelectric pulse wave (PPG) are analyzed to calculate systolic and diastolic blood pressure. The problem is the development of analysis algorithms for accuracy and reproducibility. In this study, in the development stage of a micro blood pressure measuring device, the size of the device was reduced and the measurement method was simplified, while the algorithm was to extract systolic blood pressure (SBP) using only two PPGs and obtain diastolic blood pressure (DBP). The difference value of PPG, DF_P, is inversely related to SBP, and has a proportional relationship with DBP, which can be leaked by algorithm, and DBP can be tracked through SBP.

The Effect of Health Promotion Programs on Health Promoting Behavior and Cardiovascular Risk Factors of Middle-aged Women (건강증진프로그램이 중년기 여성의 건강증진행위와 심혈관계 위험요인에 미치는 영향)

  • Park, Jeong-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.2
    • /
    • pp.233-243
    • /
    • 2002
  • Purpose: This study is aimed at testing the effect of health promotion program on health promoting behavior and cardiovascular risk factors of middle-aged women. Method: The research design was the nonequivalent control group pre-post test. Twelve middle-aged women were the experimental group and ten were the control group. The 8-week health promotion program was given to the experimental group. There were health promotion theories, flexibility and muscle strength exercise, cardiopulmonary endurance exercise, nutrition, stress management, cancer prevention and early detection, management of menopause and wrap-up in health promotion program for middle-aged women. The measurement tool was Health Promoting Behavior developed by researcher using serum cholesterol, obesity rate, systolic blood pressure, and diastolic blood pressure as cardiovascular risk factors. Result: The experimental group showed a higher score of health promoting behavior than the control group. There were no differences on cardiovascular risk factors(cholesterol, obesity rate, diastolic blood pressure) between the experimental and control groups except systolic blood pressure. Conclusion: Conclusively, this health promotion program for middle-aged women was effective in increasing health promotion behaviors, but wasn't effective in decreasing cardiovascular risk factors except the systolic blood pressure. It seems it's necessary to re-study this using more samples and a longer duration of the program, and smaller mortality rate.

  • PDF

Measurement of Leg Arterial Compliance of Normal and Diabetics (정상인과 당뇨병 환자의 다리 동맥의 Compliance 측정)

  • 김덕원;김상수
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.189-194
    • /
    • 1992
  • As people's income and intake of animal fat rapidly increase, so does choresterol concentration in blood. Thus diseases such as non-insulin-dependent diabetes mellitus(NIDDM)myocardial infraction, high blood pressure, cerebral stroke resulting from atherosclerosis rapidly increase recently. It is very difficult to diagnose atherosclerosis early since its progress is so slow and there is no sypmtoms in the beginning of the disease. In this study a mechanical characteristic, compliance, of the lower leg arteries was measured noninvasively. Changes of blood volume and pressure were measured using impedance plethysmgraphy and mercury sphygmomanometer, respectively. The compliance was calculated by dividing the change of blood volume by the change of pulse pressure ( systolic-diastolic pressure ) . Subjects were 24 asymptomatic persons ranging (rom 30 Ic 58yeras and 14 diabetics from 41 to 59years. The compliances, mean, and systolic pressures were statistically analyzed using a t-test be- tween the healthy and diabetic groups. The average compliance of the healthy and diabetic group was measured 2.79 and 1.82U1/mmHg/cm, respectively and these were significantly different(p<0.01). It was also found that the compliance is a better parameter in differentiating the vascular disease than mean or systolic blood pressure.

  • PDF

A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair

  • Kim Ko-Keun;Chee Young-Joon;Lim Yong-Gyu;Choi Jin-Wook;Park Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.83-88
    • /
    • 2006
  • A new method of measuring pulse arrival time (PAT), which is usually used for the estimation of systolic blood pressure, in an unconstrained manner using a chair, is proposed. The capacitive-coupled ECG (CC-ECG) measurement system and the air cushion with balancing tubes system were used for unconstrained PAT measurement. Firstly, the correlation between the standard PAT (S-PAT) from the photoplethysmography (PPG) and the PAT measured in an unconstrained manner (U-PAT) was evaluated. It was observed that U-PAT, which is the time delay from the R-peak of ECG to the steepest decent point of air cushion pressure wave, is significantly correlated with the S-PAT. Secondly, systolic blood pressure (SBP) measured by the radial tonometer is compared to the U-PAT. The ten-beat averaged U-PAT removed respiration effects and demonstrated a high intra-subject correlation with SBP in all participants. Finally, the tonometry SBP was estimated from these U-PAT values for one participant intermittently during half a day.

Analysis of BMI Menopose, Blood Pressure and Dietary Habits Affecting Born Mineral Density of 30~60 Years Women (30~60대 여성의 골밀도와 비만도, 폐경, 혈압, 식생활 관련 요인 분석)

  • Koo, Jae-Ok;Park, Seo-Yun
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.3
    • /
    • pp.403-414
    • /
    • 2010
  • Reducing women's bone mineral density (BMD) has close relationship to risk in osteoporosis. This study was carried out to identify bone density risk factors affecting women's BMD, and to analyze the relationship of age, between BMD and menopause, BMI, blood pressure lifestyle and dietary habits for bone health by physical measurement and questionnaires. The study subjects, 128 women living in Seoul, were divided into 4 age group; 30~39 years (17), 40~49 years (54) and 50~59 years (36) and 60~69 years (21). There were significant differences in mean height, BMI, systolic blood pressure, menache and menopause age and menopause ratio and BMD T-score among the 4 age groups. BHD was significantly decreased according to increasing age and BMI and menopause. The rate of BMD risk subjects was significantly different increasing with age and BMI. The rate of risk group were 0%, 13%, 22.2% and 71.4%, by age groups and 0%, 16.2%, 33.3% and 52.9% by BMI respectively. BMD of menopause groups was significantly decreased from 1.23 (40 years) to 1.34 (60 years). p < 0.001. Also systolic blood pressure were significantly increased from 116.5 mmHg (30 years) to 130.81 mmHg (60 years). The T-score of normal group also decreased significantly from 1.27 to 0.13 (60years) with age. There were significant negative correlation between BMD and age (r = -0.409) menopause (r = -0.346), BMI (r = -0.218) systolic blood pressure (r = -0.193), salty taste eating out (r = -0.185) (p < 0.05). There were significant positive correlation between BMD and meat fish and walking time. In conclusion, bone density decreased with age. Most of the 50 years' subjects were in risk group. BMI, menopause, systolic blood pressure, frequency alcohol consuming. To prevent osteoporosis, over 40 years needed to be educated to maintain normal weight and the improvement of eating and living habits.

Development of Blood Pressure Estimation Algorithm Using Variable Characteristic Ratios on Oscillometric Method (진동법에서 가변 특성 비를 이용한 혈압 추정 알고리즘의 개발)

  • Shin, Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.510-515
    • /
    • 2009
  • In this paper, variable characteristic ratio algorithm based on oscillometric method is proposed to enhance the accuracy of blood pressure measurement. We combined the slope-based approach and fuzzy inference technique to change the characteristic ratios of height-based method. The proposed algorithm was assessed on 255 measurements from 85 subjects and compared with the conventional height-based algorithm. The testing results showed that the developed algorithm achieved an overall grade A for both systolic and diastolic blood pressures according to the BHS protocol. And, mean standard deviation between the observers and the developed algorithm were 5.71mmHg and 6.29mmHg for systolic and diastolic pressures respectively, which also fulfilled the AAMI criteria. In conclusion, this algorithm was successfully developed and recommended for further clinical trials with the wider adult population.