• 제목/요약/키워드: System-frequency

검색결과 17,697건 처리시간 0.038초

감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구 (A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System)

  • 안찬우;최석창;김동영
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

대형 봉상 접지전극의 접지임피던스와 주파수 응답특성 (Ground Impedance and Frequency Response Characteristics of Large-scale Ground Rods)

  • 이복희;엄주홍;김태두;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1791-1793
    • /
    • 2003
  • In order to analyze the dynamic characteristics of ground impedance in large grounding system for lightning and surge protections, a novel method for measuring the ground impedance as a function of frequency was proposed. The experiments were carried out in the grounding system composed of ground rods and mesh grids. The test current was injected by the variable frequency inverter whose frequency is linearly controlled in the range of $5{\sim}500$kHz. The ground impedance and frequency response of the grounding system were mainly caused by the inductive current flowing through grounding conductors over the frequency of 2002. In the combined grounding system of rods and mesh grids, inductive component of ground impedance was significantly decreased. It was fumed out that the grounding system is effective for the surge protection.

  • PDF

135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석 (An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator)

  • 옥연호;이은웅;변일환;오석영
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

The Analysis of Protection Ratio and Its Effect of Interference-to-Noise Ratio for Digital Microwave System with Diversity

  • Suh Kyoung-Whoan;Jang Won-Gyu
    • Journal of electromagnetic engineering and science
    • /
    • 제6권3호
    • /
    • pp.189-195
    • /
    • 2006
  • In this paper, the derivation of the protection ratio for the digital microwave system with diversity is newly suggested for a basic guidance of initial planning for frequency coordination, and computational results are presented for an actual radio frequency band. The net filter discrimination has been also examined to see the effect of the adjacent channel protection ratio caused by adjacent channel interference. In addition, the protection ratios for the space or frequency diversity system are analyzed in terms of diversity improvement factors to find out an equivalent allowable noise-to-interference ratio (N/I) from degraded fade margin. According to results for 6.2 GHz system, with the space diversity of 25 m distance between antennas or the frequency diversity of ${\Delta}f/f=0.05$, under 64-QAM and 60 km at BER $10^{-6}$, the protection ratio can be greatly reduced in comparison to the non-diversity system. So, assuming that only the same protection ratio as the non-diversity system is kept, it is shown that the system with diversity may get more interference level of N/I allowing from 9.0 to - 5.9 dB or from 6.0 to - 4.3 dB for the space or frequency diversity. In consequence, it is concluded that the diversity system is more robust or tolerable for interferences or fades, which may play an important role in overcoming N/I to some extent.

부하를 분담하고 있는 디젤발전기의 무한대 모선과의 병렬운전 시스템 (Parallel Running System of the Loaded Diesel Generator to Infinite Bus)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.1017-1025
    • /
    • 2004
  • Generally generator is connected to the bus with no load. After the connection to the bus. the frequency of generator system with no load has to be increased for preventing the reverse power. But in a few case of parallel running with infinite bus system, we have to synchronize the loaded generator to the infinite bus. The frequency of generator system with load has to be lowered for prevention of load shift to the bus system. The blackout of infinite bus decreases the parallel running generator's frequency because of load increasing. In this paper we propose a method that the generator with load maintains the frequency constantly after the blackout of infinite bus. With the constant speed control and load control method of parallel running system to the infinite bus we apply the method to the industrial generating system.

주파수 영역 민감도 방법을 이용한 집중 질량 구조물의 응답 해석 (Analysis of Response of Lumped Mass System Using Sensitivity Method in Frequency Domain)

  • 백문열;기창두
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.164-169
    • /
    • 1997
  • The aim of this paper is to present some results of sensitivity analysis in frequency domain. The sensitivity fonctions in frequency domain is not depend on the external excitation but depend on the frequency of the system's resonance. The sensitivity functions are determined as function of partial derivatives of system transfer functions taken with respect to system design parameters. The logarithmic sensitivity function is the dimensionless sensitivity funciton available, making it useful to compare the influence of various parameters on system variables. Two degree of fredom system is used to illustrate the procedure for sensitivity analysis proposed in this paper.

  • PDF

초음파 도플러 시스템에서 새로운 평균 주파수 확장 방법 (A New Mean Frequency Extension Method in Doppler System)

  • 백광렬
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.183-190
    • /
    • 1995
  • The use of ultrasound pulsed Doppler systems has become increasingly popular due to the advantages of easy measurements of blood velocity, volume blood blow, and irregularities of the circulatory system. However, the 2-D Doppler systems have several problems, such as range ambiguity, low signal to noise ratio, and slow frame rate. The mean frequency aliasing problem originating from the pulse repetition frequency is one of major limitations in pulsed Doppler systems. A conventional approach to resolve this problem is tracking the mean frequency close to and beyond the Nyquist frequency along the temporal axis. In this paper, a new concept of tracking the mean frequency along the spatial axis is proposed. The proposed technique is fault tolerant by nature and more suitable for multi gate and 2-D Doppler system than conventional methods.

  • PDF

국내외 PV PCS 기술현황 (Recent PV PCS Technology)

  • 최주엽;유권종;정영석;소정훈;최익
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.117-122
    • /
    • 2005
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency converter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AC filter. The high frequency converter bridge switching at 20kHz is used to generate bipolar PWM pulse, and the high frequency transformer raise its voltage twice, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. Even though the high frequency link system needs more power semiconductors, a reduced size, light weight, and saved parts cost make this system more comparative than the other systems due to elimination of 60Hz transformer.

  • PDF

변화하는 감쇠를 갖는 계가 조화력을 받을 때의 운동 - 이론적 해석 (Motion of a System with Varying Damping Subject to Harmonic Force - Analytical Analysis)

  • 박오철;이건명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.898-902
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation ${\Large f}_1\;and\;{\Large f}_2$ respectively, the displacement at the center of the plate has the strongest component at frequency ${\Large f}_1$. The angular displacement of the plate has strong components at ${\Large f}_1-{\Large f}_2$ and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. Part of these simulation results are proved analytically.

  • PDF

레이더용 주파수합성기의 위상잡음 모델링 및 분석 (Modeling and Analysis of the Phase Noise in a Frequency Synthesizer for a Radar System)

  • 김동식;김민철;이수호;정명득;권호상
    • 한국군사과학기술학회지
    • /
    • 제14권5호
    • /
    • pp.818-824
    • /
    • 2011
  • In this paper, we proposed a phase noise model of a frequency synthesizer for a radar system. Especially, it was proposed a phase noise model in a DAS(Direct Analog Synthesizer) and a frequency up converter system using Leeson's model. The proposed phase noise model was derived from the measurement data of model 1 and evaluated by adapting to model 2 and model 3 frequency synthesizers. The prediction phase noise by modeling was totally matched to the measured data and the effective analysis of the phase noise was done in a frequency synthesizer and a frequency converter of radar system.