• 제목/요약/키워드: System operation type

검색결과 2,044건 처리시간 0.031초

Battery type 외과수술용 핸드피스 구동 드라이브 시스템 (Development of Battery Type Powered Handpiece Drive System for Surgical Operation)

  • 하정준;윤용호
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

기선권현망어업의 3척식 자동화 양망시스템 개발 (Development of the Automatic Hauling Operation System by Three boats for Anchovy Boat Seine)

  • 안영수;장충식;이명규
    • 수산해양기술연구
    • /
    • 제41권2호
    • /
    • pp.147-155
    • /
    • 2005
  • This study was conducted in order to improve the automatic fishing operation system for anchovy boat seine by comparison with the fishing gear geometry and efficiency using the labor saving nets and the combined type net with midwater trawl. Field experiments were carried out to observe the geometry of nets and improve the fishing operation system by catcher boats. The vertical net opening of fore wing net, square, fore bag net and after bag net of the combined type net were varied in the range of 9.9~12.9. 16.2~28.2, 6.8~12.1 and 9.5~15.2m respectively, when the towing speed was 1.0m/sec and the distance between boats were 100m, 200m, 300m. The vertical net opening of the combined type nets was gradually decreased as function of with increasing the distance between catcher boats. Labor saving net which was maintained the net opening and towing depth stable was more suitable for the automatic hauling operation system by improvement of bag net rather than the combined type nets which was impossible in swallow depth and near to anchovy school. 3 boats hauling operation system of the labor saving net was carried out by crane with power block in 2 catcher boats for improvement of hauling operation and pushing equipment of anchovy cooking system in the processing boat for maintain more anchovy in dry frame. From the results of field experiments, 3 boats hauling operation system with power block and improved cooking system was very 3 boats hauling operation system with power block and improved cooking system was very useful and more practical as hauling time 20~35min and No. of fishermen 12~13 in comparison with the traditional system such as hauling time 30~50 min and No. of fishmen 28~38.

멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘 (A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

표준전동차 자동/무인운전장치 개발 및 주행시험 (Development and Test of Automatic/Driverless Operation System for Standardized EMU)

  • 안태기;이수길;한성호;이관섭
    • 한국철도학회논문집
    • /
    • 제3권3호
    • /
    • pp.154-160
    • /
    • 2000
  • The automatic/driverless operation which are great important techniques in metro railway are required to increase higher safety, greater reliability, and transport capacity. To satisfy such demands, we must have the system design and testing technique for the railway system operation. These techniques are related to the onboard train control and communication systems which include TCMS(Train Control and Monitoring System), ATO(Automatic Train Operation), ATC(Automatic Train Control), and TWC(Train to Wayside Communication). These sub-systems must be interfacing with not only each others but also the signal system on the ground. We tested the train control system on Test line that has been developed on the basis of the standardized type EMU for korea railway systems. This test line which is located in Sangju, have been constructed for testing 7 & 8 line of Seoul Metro railway.

  • PDF

표준전동차 자동/무인운전기술 개발 및 시운전에 관한 연구 (Test operation and development of Automatic/Driverless operation system for the standardized type EMU)

  • 한성호;안태기;이수길;이관섭;김원경;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.172-179
    • /
    • 2000
  • The automatic/driverless operation which are great important techniques in metro railway are required to increase higher safety, greater reliability, and transport capacity. To satisfy such demands, we must have the system design iかd testing technique for the railway system operation. These techniques are related to the onboard train control and communication systems which include TCMS(Train Control md Monitoring System), ATO(Automatic train Operation), ATC(Automatic train Control), and TWC(Train to wayside communication). These sub-systems must be interfacing with not only each others but also the signal system on the ground. We tested the train control system on Test line that has been developed on the basis of the standardized type EMU for korea railway systems. This test line which is located in Sangju, have been constructed for testing 7 & 8 line of Seoul Metro railway.

  • PDF

Analysis on operation characteristics and power burdens of the double quench trigger type SFCLs

  • Lim, Seung-Taek;Lim, Sung-Hun;Han, Tae-Hee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.33-37
    • /
    • 2017
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. The capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system operator need a counter-measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as effective solutions to reduce the fault current. For the above reasons various type SFCLs have been studied recently. In this paper, operation characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. Another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

전압증가 시 재폐로 동작에 따른 변압기형 초전도 한류기의 특성 분석 (Characteristics on the Transformer-Type SFCL According to Reclosing Operation the Voltage Increase)

  • 최수근;최효상
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.477-480
    • /
    • 2010
  • Fault current in power system is expected to increase by demand of power capacity. Therefore, when the fault occurred, fault current was increased in the power system. Many studies have been progressed to limit the fault current. Superconducting fault current limiter (SFCL) is one of them which has been studied in worldwide. In this paper, we will analyze characteristics of a transformer-type SFCL by reclosing operation when the voltage increases. Twice opening times in the reclosing of circuit breaker were set as the 0.5 and 15 seconds, respectively. Turn's number of primary and secondary coils set 4:2 and we increased voltages from 120V to 280V for each experiment. By the current waveform, maximum fault current in second and third cycles was lowered when the voltage was increased. In the recovery waveform, recovery time was increased as the voltage was increased. The reason was that power burden of the SFCL increased when consumption power was increased, so the time to get back to SFCL took longer. We compared the characteristics of a resistive-type and transformer-type SFCL. As a result, we found that the fault current of a transformer-type was lower than resistive-type and recovery time of the SFCL was shorter. Consequently, transformer-type SFCL was more profitable for limitation of fault current and recovery time under the same condition for reclosing operation.

전자유압제어식 리그형 CVT 개발과 최적운전 (Development and Optimal Operation of an Electro-Hydraulic Controlled Rig Type CVT)

  • 김광원;권혁빈;김현수;은탁;박찬일
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2181-2190
    • /
    • 1993
  • An electro-hydraulic controlled rig type CVT(Continuously Variable Transmission) system was developed and its performance tests were carried out for the optimal operation. A CVT map was suggested based on the speed ration-axial force-torque relationship which was derived from the metal belt CVT mechanics. Also, a real time control and operation software was developed for the electro-hydraulic CVT system. By using the software and the CVT map, the control system was designed for the CVT speed ratio control with various drive modes. The electro-hydraulic CVT system developed in this study showed that the optimal operation algorithm could be obtained for the best fuel economy or the maximum power mode.

아크유도형 DC 차단기의 동작 특성 (Operating Characteristics of Arc-induction Type DC Circuit Breaker)

  • 박상용;최효상
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.981-986
    • /
    • 2018
  • AC(alternating current) CB(circuit breaker) at the fault occurred in the existing AC distribution system is limiting the fault current through zero cross-point. However, DC(direct current) CB does not have zero cross-point. Therefore, arc occurred by on-off operation of DC CB is very huge. Nowadays, many research team are studying the way to decrease breaking time, which is one of the essential conditions in DC CB. We suggested novel arc-induction type DC CB in this paper. The proposed arc-induction type DC CB is composed of the mechanical Arc ring and DC CB. We confirmed the operation of arc-induction type DC CB through the HFSS(High Frequency Structure Simulator) 3D simulation program and performed the experiment for operation characteristics. Results showed that arcing time of the arc-induction type DC CB by using induction ring was faster than existing mechanical DC CB. On the transient system, we confirmed stable operation characteristics of the arc-induction type DC CB through the simulation and experimental results. We expect that the proposed arc-induction type DC CB technology is will go to stay ahead of the existing DC CB technology.