• 제목/요약/키워드: System air permeability

검색결과 96건 처리시간 0.023초

유류로 오염된 철로지역의 지중정화를 위한 영향반경 산정과 공기주입법/토양증기추출법의 적용성 평가 (Calculation of Radius of Influence and Evaluation of Applicability of Air Sparging/Soil Vapor Extraction system for the Remediation of Petroleum Contaminated Rail Site)

  • 조장환;박정구;김용덕;서창일;김해금;최상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2015
  • The objectives of this study were to calculate the radius of influence (ROI) of well for an air-sparging (AS)/soil vapor extraction (SVE) system and to evaluate the applicability of the system applied for the remediation of the petroleum contaminated rail site. For air permeability test, three monitoring wells were installed at a location of 1.3 m, 2.3 m, 3.0 m from the extraction well. And the pressure of each monitoring well was measured by extracting air from the extraction well with the pressure and flow of $(-)2,600mmH_2O$ and $1.58m^3/min$. The ROI for an extraction well was calculated as 4.31 m. Air was injected into the injection well with the pressure and flow of $3,500mmH_2O$ and $0.6m^3/min$ to estimate the radius of influence for oxygen transfer. Oxygen concentrations of air from three monitoring wells were measured. The ROI of an injection well for oxygen transfer was calculated as 3.46 m. The 28 extraction wells and 19 injection wells were installed according to the ROI calculated. The AS/SVE system was operated eight hours a day for five months. The rail site was contaminated with the petroleum and concentrations of benzene, toluene, and xylene were over the 'Worrisome Standard' of the 'Soil Environment Conservation Act'. The contaminated area was estimated as $732m^2$ and contaminants were dispersed up to (-)3 m from the ground. During the operation period, soil samples were collected from 5 points and analyzed periodically. With the AS/SVE system operation, concentrations of benzene, toluene, and xylene were decreased from 7.5 mg/kg to 2.0 mg/kg, from 32.0 mg/kg to 23.0 mg/kg, from 35.5 mg/kg to 23.0 mg/kg, respectively. The combined AS/SVE system applied to the rail site contaminated with volatile organic compounds (VOCs) exhibited a high applicability. But the concentration of contaminants in soil were fluctuated due to the heterogeneous of soil condition. Also the effect of the remediation mechanisms was not clearly identified.

Effect of spinning parameters of polyethersulfone based hollow fiber membranes on morphological and mechanical properties

  • Tewfik, Shadia R.;Sorour, Mohamed H.;Shaalan, Hayam F.;Hani, Heba A.
    • Membrane and Water Treatment
    • /
    • 제9권1호
    • /
    • pp.43-51
    • /
    • 2018
  • Hollow fiber (HF) membranes are gaining wide interest over flat membranes due to their compaction and high area to surface volume ratio. This work addresses the fabrication of HF from polysulfone (PS) and polyethersulfone (PES) using N-methylpyrrolidone (NMP) as solvent in addition to other additives to achieve desired characteristics. The semi-pilot spinning system includes jacketed vessel, four spinneret block, coagulation and washing baths in addition to dryer and winder. Different parameters affecting dry-wet spinning phase inversion process were investigated. Dope compositions of PES, NMP and polyvinyl pyrrolidone (PVP) of varying molecular weights as additive were addressed. Some critical parameters of importance were also investigated. Those include dope flow rate, air gap, coagulation & washing baths and drying temperatures. The measured dope viscosity was in the range from 1.7 to 36.5 Pa.s. Air gap distance was adjusted from 20 to 45 cm and coagulation bath temperature from 20 to $46^{\circ}C$. The HF membranes were characterized by scanning electron microscope (SEM), atomic force microscope (AFM) and mechanical properties. Results indicated prevalence of finger like structure and average surface roughness from about 29 to 78.3 nm. Profile of stress strain characteristics revealed suitability of the fibers for downstream interventions for fabrication of thin film composite membrane. Different empirical correlations were formulated which enable deeper understanding of the interaction of the above mentioned variables. Data of pure water permeability (PWP) confirmed that the fabricated samples fall within the microfiltration (MF)-ultrafiltration (UF) range of membrane separation.

청바지의 소재별 쾌적감에 관한 연구 (Comport Sensation of Blue Jeans depending on Fiber Contents)

  • 홍문경;이미식;권계화;전정애
    • 한국의류학회지
    • /
    • 제25권2호
    • /
    • pp.237-248
    • /
    • 2001
  • The purpose of this study was to compare the comfort sensation depending on four different kinds of denim blue jeans: cotton, cotton/tencel, tencel, cotton/pp. The objective and subjective experiments were conducted to measure the comfort of blue jeans. To investigate the objective comfort, physical properties related to thermal insulation, moisture properties and hand were measured. For subjective comfort measurement, 5 healthy female college students were taken as subjects. The outcomes of the experiments are as follows: The higher the air permeability and bulk density of the denim, the lower the thermal insulation, the thicker the denim, the higher the thermal insulation. Tencel blending denim showed the higher bulk density, the lower air contents, and consequently the lower thermal insulation than the other denims. Tencel showed the highest moisture regain, and cotton/tencel blend showed the highest water vapor permeability. Tencel denim had relatively better flexibility, shape stability and elastic recovery than the other denims. The total hand values of the denims by KES-FB system were not significantly different. Cotton and cotton/pp denims raised the subjects body temperature after excercise more than tencel or cotton/tencel denims. Average skin temperature was found to have a correlation with micro climate temperature and micro climate humidity. The correlation coefficients were 0.749 and 0.767, respectively. However, average skin temperatures were not significantly different among the materials. Pulse rate was found to be the highest when wearing cotton/pp and the lowest in case of cotton/tencel denim. The energy was consumed in order of cotton>cotton/pp>tencel>cotton/tencel. There was no significant difference in preference before excercise, but, after the excercise, the order of preference changed as the following; cotton/tencel>tencel>cotton/pp>cotton.

  • PDF

질소 분리용 막을 이용한 매립가스내 메탄 회수 연구 (Research on the Methane Recovery from Landfill Gas by Applying Nitrogen Gas Separator Membrane)

  • 천승규
    • 대한환경공학회지
    • /
    • 제35권8호
    • /
    • pp.586-591
    • /
    • 2013
  • 정제 질소가스 생산용 기체 분리막을 매립가스의 $CH_4$ 순도를 높이는데 활용하기 위한 연구를 수행하였다. 1단과 2단 분리막 모듈의 면적비는 1:6인 경우가 $CH_4$ 회수를 위해서 적절하였다. 분리막 장치 설치 후 총 249회에 걸쳐 실험을 하였으며, 투과율은 평균 $CH_4$ 28.4%, $CO_2$ 94.3%로서, 매립가스로부터 $CH_4$를 회수하는데 $N_2$ 분리막의 사용 가능성을 확인할 수 있었다. 다만, $N_2$ 투과율 역시 16.5%에 불과하였으며, 이에 따라 최종 정제된 LFG의 농도는 $CH_4$ 69.7%, $CO_2$ 4.3%, $N_2$ 26.0%이었다. 따라서 $CH_4$의 순도를 높이기 위해서는 매립장내 외기유입 억제를 통해 $N_2$ 농도를 적어도 2.0% 이내로 제한할 필요가 있었다.

마직물 및 마혼방직물의 온열특성에 대한 흡습의 영향 (The Effect of Absorption Water on Thermal Properties of Pure Linen and Linen Blended Woven Fabrics)

  • 권오경;이참미;성우경
    • 한국의류산업학회지
    • /
    • 제1권2호
    • /
    • pp.160-165
    • /
    • 1999
  • The thermal properies of the pure linen fabrics available in the market and linen blended woven fabrics were measured at the moisture content of 0%, 20%, 40% and 60% using KES-F7 system (Thermo Iabo II type). The experimental properties were statistically analyzed by the rate of water absorbent. The main results were as follows; There is a positive correlation between the thermal insulation value (TIV) and thickness of pure linen fabrics and linen blended woven fabrics by water absorption. Whereas an negative correlation exists between the TIV and cover factor. There is a high positive correlation among the thermal conductivity (k), thickness and weight of pure linen fabrics and linen blended woven fabrics by water absorption. Wherase a high negative correlation exist between the k and air' permeability (Ap). There is a high positive correlation between the feeling of warmth/coldness and bulk density of pure linen and linen blended woven fabrics by water absorption. Wherase a high negative correlation exists between the feeling of warmth/coldness and porosity. There is a negative correlation between TIV and $q_{max}$ of pure linen fabrics and linen blended woven fabrics. The higher the rate of water absorbent, the lower the TIV. This means that TIV decreases by water absorption. As for the thermal property by rate of water absorbent $q_{max}$ and k increase by water absorption and reach max-value at 60% rate of water absorbent. The TIV decreases by water absorption and has +value at 0% rate of water absorbent, whereas it has -value with a feeling of coldness at 20%, 40%. and 60% rate of water absorbent.

  • PDF

Effect of the Calcium Nitrate Solution Treatment on the Tensile, Bending, and Shear Properties of Silk Fabric

  • Park, Su-Zin;Kang, Ji-Young;Seol, Da-Won;Yang, Hye-Min;Lee, Ji-Min;Ahn, Ye-Ji;Han, Seo-Young;Kim, Jong-Jun
    • 패션비즈니스
    • /
    • 제14권6호
    • /
    • pp.39-52
    • /
    • 2010
  • Interests in creating three-dimensionally designed fabric materials are growing rapidly in the sectors of the fashionable textiles with the creativity, new functions, and aesthetics. A number of finishing methods have been developed and proposed to add or create new functions and designs for silk fabrics. Due to the strong hydrogen bonds between the molecules of silk fibroins, the thermal treatment methods used in thermoplastic fiber processing, which can easily deform the synthetic filament fabrics to endow three-dimensional appearance to the fabrics, are not applicable to the silk fabric treatment. In order to modify the fine structure of silk fiber, neutral salt solution treatment methods have been suggested. In this study, the effect of the calcium nitrate solution on the physical and mechanical properties of silk fabrics was investigated by using the KES(Kawabata Evaluation System) equipment. Based on these findings, relationships between parameters, for example, the thickness and the compressional energy, the thickness and the compressional linearity, and the air permeability and the pore area statistical analysis were investigated. The relationships between the process parameters such as treatment temperature/time and the resulting fabric property parameters were also analyzed by using several SAS procedures.

콘크리트 진공튜브의 압력 변화에 대한 확률적 평가 (Probabilistic Study on Pressure Behavior in Concrete Vacuum Tube Structures)

  • 박주남
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.186-192
    • /
    • 2014
  • 본 연구에서는 콘크리트 진공튜브 구조의 설계에 있어서 주어진 재료 및 시스템 구성에서 존재하는 불확실성을 정량화하여 내부기압의 변화를 확률적으로 예측할 수 있는 신뢰성 평가를 수행하였다. 시스템 등가투기계수의 산정 및 외부기압에 영향을 주는 인자들 중 불확실성을 내재하고 있는 인자들을 확률변수로 모델링한 후 수식 유도 및 시뮬레이션을 통해 시간에 따른 내부기압의 변화를 확률적으로 예측하였으며 확정적 해석과 그 결과를 비교 분석한 결과 적정 수준의 신뢰성을 얻기 위해서는 단면의 변화가 반드시 필요한 것으로 나타났다. 이와 같은 튜브구조의 기밀성능에 대한 확률적 해석 결과는 튜브 내부를 주행하는 열차 또는 다른 운송수단의 추진력과 공기저항, 그리고 펌프의 용량을 복합적으로 고려하여 목표 압력을 정하고 튜브 단면을 결정하는데 필요한 기술적 자료로써 활용될 수 있을 것이다.

성능저하된 철근콘크리트구조물 폴리머시멘트계 보수용 단면복구재의 내구성 평가에 관한 실험적 연구 (An Experimental Study on the Durability Evaluation of Polymer Cement Restoration Materials for Deteriorated Reinforced Concrete Structures)

  • 김무한;김재환;조봉석;박종호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.123-130
    • /
    • 2006
  • 콘크리트의 열화 및 철근부식에 대응하기 위하여 다양한 보수재료가 존재하나 이러한 보수재료를 평가하는 방법은 단순히 염해, 중성화 등의 단독열화만을 대상으로 하고 있어 여러 가지 열화인자가 복합적으로 작용하는 실제 환경과는 차이를 나타내게 된다. 따라서 본 연구에서는 폴리머시멘트계 보수용 단면복구재가 KS 기준을 만족하는지 확인한 후 복합열화 환경 하에서 염해, 중성화. 철근부식을 평가하였다. 실험결과 각각의 보수재료들은 KS 기준을 만족하였지만 내구성능은 상이하게 나타나 향후 이에 대한 고려가 필요할 것으로 사료된다.

복공식 지하 압축공기에너지 저장공동의 열역학적 에너지수지 분석 (Thermodynamic Energy Balance Analysis of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES))

  • 김형목;박도현;류동우;최병희;송원경
    • 터널과지하공간
    • /
    • 제21권4호
    • /
    • pp.297-306
    • /
    • 2011
  • 본 연구에서는 지하 압축공기에너지 저장공동 주변 지하수 및 압축공기의 유체유동과 열전달 거동 해석을 위한 다상다성분 열유동 해석 결과를 이용하여 지하 저장공동의 열역학적 에너지수지 분석을 통한 에너지 효율평가를 실시하였다. 복공재인 콘크리트 라이닝이 충분한 기밀성능을 발휘할 경우, 주입 압축과정에서 저장공동으로부터 손실되는 에너지의 대부분은 콘크리트 라이닝 및 주변 암반에의 열전도를 통해 발생함을 확인하였다. 지하 압축공기에너지 저장공동의 에너지 효율은 압축공기 주입온도에 민감한 결과를 보였으며, 주입온도가 주변 암반의 온도에 근사할 경우, 손실된 에너지의 대부분이 토출 팽창과정에서 저장공동으로 유입 회수되는 결과를 보였다. 한편, 콘크리트 라이닝의 열전도특성이 저장공동의 에너지효율에 미치는 영향은 크지 않았다.

한복의 보온력 평가를 위한 컴퓨터 시뮬레이션 (Computer Simulation for Calculation of Thermal Insulation in Korean Folk Clothes)

  • 권오경;성수광
    • 한국의류학회지
    • /
    • 제21권7호
    • /
    • pp.1153-1161
    • /
    • 1997
  • The insulation provided by clothing system is usually expressed in terms of a coo units and its distribution of the body, directly affect convective, conductive, and radiant heat loss from the skin to the environment Evaporated heat loss is dependent upon fabric permeability, the amount of body surface area covered by clothing, and the pumping of air between the body and garment layers. Persons at low to medium activity levels, dressed in conventional apparel in door environments, usually do not lose a large amount of heat through evaporation. Thermal manikin technology is used to measure the resistance to heat transfer provided by clothing systems. The reciprocal of this value, 6.45 W/m2.$^{\circ}C$ is often used in calculations for convenience. The purpose of this study was to implement a research program for calculation the insulation value (clo), body surface area and basal metabolic rate of selected clothing system. The project provided for the building of an insulation data base for use in evaluating and comparing new and improved garments.

  • PDF