• Title/Summary/Keyword: System IC

Search Result 1,159, Processing Time 0.024 seconds

Development of Multiple Channel Measurement System for IC Socket (IC 소켓 검사용 다중 채널 측정 시스템 개발)

  • Gang, Sang-Il;Song, Sung-Yong;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.315-321
    • /
    • 2021
  • In this paper, we have developed the multiple channel measurement system for IC Socket Test. The one can test the current-voltage measurements for pitting the several device specification, which analyze the thin current from several ㎂ to 5A with very low resistor mΩ. The increasement of the IC socket channel with lead pitch under 0.25 mm be need to perform several functions, concurrently. The system to perform these functions be designed to integrate several SMU(source measure unit) on board. So, we can reduce the 2 minutes test time per channel point to 40 sec, with daisy chain test method. Using by graphic interface, I-V curve mode and data logging technologies, we can implement the test flow methods and can make economies the time and cost.

The Ballast IC with AZVS(Active Zero Voltage Switching) for CFL (AZVS(Active Zero Voltage Switching) 기능을 갖는 CFL용 안정기 제어 IC)

  • Cho, Gye-Hyun;Lee, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1037-1038
    • /
    • 2006
  • CFL(Compact Fluorescent Lamp)는 기존에 사용되던 백열 램프를 바로 대치할 수 있고, 백열 전구에 비하여 광 효율이 우수하다는 장점으로 인해서 사용처가 점점 증가되고 있는 추세이다. 하지만 등기구가 가지는 공간적인 제약으로 인해서 EMI 필터와 PFC 회로를 내장할 수 없으며, 램프에서 발생한 열이 직접적으로 안정기 회로에 영향을 주어 안정기 내부 온도가 매우 높게 상승한다는 점으로 인해서 다양한 기능을 갖는 전용 ballast control IC를 사용할 수 없었다. 이러한 이유로 인해서 toroidal core를 이용한 자려식(self-excited) 동작 방법이 주로 이용되어왔다. 이러한 자려식 발진 방법은 설계하기가 까다롭기 때문에 램프 점등 전에 램프 필라멘트를 예열한 이후에 점등을 하는 rapid start 방법을 구현하기 어려웠다. 본 논문은 fairchild 반도체에서 만든 CFL 전용 ballast IC가 가지는 특성에 대해서 다루었다. IC 내부에 안정기 동작을 제어하기 위한 제어 부분과 두 개의 MOSFET를 내장하고 있어 안정기 구성에 필요한 공간을 최소화할 수 있고, 부하 상태를 검출하여 항상 Active ZVS 동작을 하도록 하는 기능을 내장하고 있어서 스위칭 손실을 최소화할 수 있다는 장점을 가지고 있다.

  • PDF

The Application of Machine Vision to IC Surface Inspection

  • Chung, Yi-Chan;Tsai, Chih-Hung;Lin, Yu-Tang
    • International Journal of Quality Innovation
    • /
    • v.4 no.2
    • /
    • pp.50-64
    • /
    • 2003
  • During IC inspection, which includes the two parts of Mark and Lead, the deviation of IC on the tape occurring in high speed movements usually generates light reflection effect, which in turn causes errors in IC recognition as measured by machine vision system. This research filters the light reflection effect by developing standard components, identifies the correct position of IC Lead, hence fixes the measurement errors or non-measurability caused by light reflection, avoids the resulting discontinued operation of measuring system, and improves the productivity.

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Nephron Heterogeneity of Renin Release in Rat Kidney Slices: Effects of L-Isoproterenol, Angiotensin II and TMB-8

  • Seul, Kyung-Hwan;Kim, Suhn-Hee;Koh, Gou-Young;Cho, Kyung-Woo
    • The Korean Journal of Physiology
    • /
    • v.25 no.1
    • /
    • pp.61-67
    • /
    • 1991
  • In order to determine possible relationships between the renin-angiotensin system and nephron heterogeneity, we compared the response of renin release and the angiotensin-converting enzyme (ACE) activity from different areas of the rat kidney. We used the renal cortical slices from the capsular surface to the juxtamedullary junction. Slices from outer one-third of the cortex were designated as outer cortical slices (OC), middle one-third as midcortical slices (MC), and inner one-third as inner cortical slices (IC). The renal renin content markedly decreased from OC and MC to IC. The basal lenin release was higher in OC than in MC or IC. On the contrary the percent change of renin release in response to L-isoproterenol was significantly higher in MC than in OC or IC. By TMB-8, the renin release in MC by $231{\pm}21%$ was higher than OC by $171{\pm}19%$ or IC by $$162{\pm}19. Angiotensin II suppressed renin release in OC and MC by $68{\pm}2,\;71{\pm}4%$ respectively, but only $40{\pm}7%$ in IC. The ACE activity was higher in IC than in OC, MC, medulla and papilla. The present data indicate that renin content and basal lenin release gradulally decreased from outer (OC) to inner (IC) cortex. The renin release in response to beta-adrenergic agonist, L-isoproterenol and intracellular calcium antagonist, TMB-8 were higher in MC than in OC and IC, but angiotensin II suppressed renin release less in IC than in OC and MC. It is suggested that juxtaglomerular cells of outer, mid-and inner cortices show a difference in renin release response to the stimuli.

  • PDF

MPPT Control of Photovoltaic using Variable IC Method (가변 IC 방법을 이용한 태양광 발전의 MPPT 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.27-34
    • /
    • 2012
  • This paper proposes variable incremental conductance(IC) algorithm for maximum power point tracking(MPPT) control of photovoltaic. The conventional perturbation & observation(PO) and IC MPPT control algorithm generally uses fixed step size. A small step size reduces a tracking error in the steady state but slows a tracking speed in the transient state. Also, a large step size is fast a tracking speed but increases a tracking error. Therefore, this paper proposes variable IC MPPT algorithm that adjust automatically step size according to operating conditions. To improve a tracking speed and accuracy, when operating point is far from the maximum power point(MPP), the step size uses maximum value and when a operating point is near from the MPP, the step size uses variable step size that adjust according to slope of P-V curve. The validity of MPPT algorithm proposed in this paper prove through compare with conventional PO and IC MPPT algorithm.

Smart Battery System of Lithium ion Batteries (리튬이온전지의 Smart Battery System)

  • Kim Hyun-Soo;Moon Seong-In;Yun Mun-Soo;Ko Beyng-Hi;Park Sang-Kun;Shin Dong-O;Yoo Seong-Mo;Lee Seung-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.132-137
    • /
    • 2001
  • Recently, the demand for notebook PC with lithium ion batteries has steadily increased and consumers require them to adopt a SBP(smart battery pack) able to predict the remaining capacity and the run time of batteries precisely. The SBP is composed of a protection If, by which safety of lithium ion batteries is maintained against overcharge, overdischarge and overcurrent, and a smart IC, which calculates the remaining capacity and the remaining run time. The protection IC shut abmormal current down by using overcharge/overdischarge FET. A SBS(smart battery system) is composed of a system host, a smart battery and a smart battery charger. The smart ICs for SBP will be required to provide a low cost, low current consumption and small size. There will need to develop a microcomputer control type IC and an optimum algorism which is able to predict the residual capacity and the residual run time precisely. SBS will apply to many kinds of industry fields such as an electric bicycle, an electric vehicle, a load levelling and a military.

Manufacture of Custom IC and System for Multi-channel Biotelemeter (다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작)

  • 서희돈;박종대
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF