• Title/Summary/Keyword: System Factor

Search Result 12,750, Processing Time 0.036 seconds

The Importance of On-line Store Characteristics Depending on On-line Store Type (온라인 의류 점포유형에 따른 점포속성 중요도)

  • Kim, Eun-Sook;Kim, Mi-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.8
    • /
    • pp.1310-1320
    • /
    • 2007
  • This study investigated the differences in the importance of store characteristics depending on on-line clothing store type and consumer age. The questionnaires were given to female residents in the ages between 20-39 in Seoul and Kyung-gi province during October 2006. The results were summarized as follows: 1. By analyzing the differences in importances of on-line store characteristics factors it was found that buying process service factor and product searching system factor were important in on-line general merchandise store. and buying process service factor and product factor(all the factors, such as store credit, product, screen-displayed design, searching and approaching system, customer management service) were important in on-line specialty store. 2. By analyzing the differences in importances of on-line store characteristics depending on the store type, buying process system such as refund policy, shipping, high-speed payment and rapid searching, screen-displayed design system, approaching and searching system were more important in on-line general merchandise store when comparing to specialty store. It also showed that the consumer considered the reputation of the store and its image more important in on-line general merchandise store. 3. By analyzing the differences in of on-line clothing store importance depending on age, in the case of on-line general merchandise store, it showed that people in their thirties regarded buying process service factor more important than twenties, and when it came to the product and searching system, it was vice versa. Twenties had a tendency to consider the aspect of product important and, relatively, thirties regarded searching and approaching system factor important. in the case of specialty store. It was found that women in their twenties had a tendency to consider product factor more important.

A Study on the Power Factor Improvement of V47-660 kW Wind Turbine Generation System in Jeju Wind Farm (제주 풍력발전 단지의 V47-660 kW 시스템의 역률개선에 관한 연구)

  • Kim, Eel-Hwan;Jeon, Young-Jin;Kim, Jeong-Woong;Kang, Geong-Bo;Huh, Jong-Chul;Kim, Gun-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.45-53
    • /
    • 2003
  • This paper presents a study on the power factor improvement of V47- 660 [kW] Wind Turbine Generation System (WTGS) in Jeju wind farm, as a model system in this paper. In this system, the power factor correction is controlled by the conventional method with power condensor banks. Also, this system has only four bank steps, and each one capacitor bank step is cut in every one second when the generator has been cut in. This means that it is difficult to compensate the reactive power exactly according to the variation of them. Actually, model system has very low power factor in the area of low wind speed, which is almost from 4 to 6 [m/s]. This is caused by the power factor correction using power condenser bank. To improve the power factor in the area of low wind speed, we used the static var compensator(SVC) using current controlled PWM power converter using IGBT switching device. Finally, to verify the proposed method, the results of computer simulation using Psim program are presented to support the discussions.

A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost (발전비용의 부하역률 감도를 이용한 효율적인 역률 개선 연구)

  • Lee, B.H.;Oh, M.H.;Kim, J.H.;Shim, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.196-198
    • /
    • 2003
  • The low load power factor causes various problems such as the increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is derived and its effects in supplying the reactive power and enhancing the load power factor are analyzed in a small-scale power system. The load power factor sensitivity of the generation cost is applied for determining the locations and capacities of reactive power compensation devices. It is shown that the generation cost can be reduced and the system power factor can be enhanced effectively using the load power factor sensitivity.

  • PDF

A Study on Enhancing the Load Power Factor from the Point of View of Economic Operation Using the Load Power Factor Sensitivity Method (부하역률 감도기법 적용에 의한 전력시스템의 경제운용 측면에서의 역률개선 방안 연구)

  • Lee B. H.;Kim J. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.153-155
    • /
    • 2004
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the integrated costs are used for determining the value of the load power factor from the point of view of the economic operation. It is shown through the application to a large-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

Multi-Factor Authentication System based on Software Secure Card-on-Matching For Secure Login (안전한 로그인을 위한 소프트 보안카드 기반 다중 인증 시스템)

  • Lee, Hyung-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.28-38
    • /
    • 2009
  • Login process uses both ID and password information to authenticate someone and to permit its access privilege on system. However, an attacker can get those ID and password information by using existing packet sniffing or key logger programs. It cause privacy problem as those information can be used as a hacking and network attack on web server and web e-mail system. Therefore, a more secure and advanced authentication mechanism should be required to enhance the authentication process on existing system. In this paper, we propose a multi-factor authentication process by using software form of secure card system combined with existing ID/Password based login system. Proposed mechanism uses a random number generated from the his/her own handset with biometric information. Therefore, we can provide a one-time password function on web login system to authenticate the user using multi-factor form. Proposed scheme provide enhanced authentication function and security because it is a 'multi-factor authentication mechanism' combined with handset and biometric information on web login system.

Effect of Divergence Ratio on Heat Transfer and Friction Factor in the Diverging Channel (확대 채널에서 확대율이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Lee, Myung-Sung;Jeong, Seong-Soo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.64-70
    • /
    • 2013
  • The heat transfer and friction factor characteristics of turbulent flows in three stationary channels have been investigated experimentally to check out the effect of divergence ratio. These are a constant cross-sectional channel and two diverging channels with ratio of divergence(Dho/Dhi) of 1.16 and 1.49. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000 and the dimension of uniform cross-sectional test section is $100mm{\times}100mm$ at the cross section and 1,000 mm in length. The measurements of heat transfer coefficients and friction factors in the uniform channels were conducted as a reference. Because of the streamwise flow deceleration, the heat transfer and friction factor characteristics in the diverging channel were quite different from those of the constant cross-sectional channel. The effective friction factors and convective heat transfer coefficients increased with increasing the ratio of divergence of the channel.

A Study on Multibiometrics derived from Calling Activity Context using Smartphone for Implicit User Authentication System

  • Negara, Ali Fahmi Perwira;Yeom, Jaekeun;Choi, Deokjai
    • International Journal of Contents
    • /
    • v.9 no.2
    • /
    • pp.14-21
    • /
    • 2013
  • Current smartphone authentication systems are deemed inconvenient and difficult for users on remembering their password as well as privacy issues on stolen or forged biometrics. New authentication system is demanded to be implicit to users with very minimum user involvement being. This idea aims towards a future model of authentication system for smartphones users without users realizing them being authenticated. We use the most frequent activity that users carry out with their smartphone, which is the calling activity. We derive two basics related interactions that are first factor being arm's flex (AF) action to pick a phone to be near ones' ears and then once getting near ear using second factor from ear shape image. Here, we combine behavior biometrics from AF in first factor and physical biometrics from ear image in second factor. Our study shows our dual-factor authentication system does not require explicit user interaction thereby improving convenience and alleviating burden from users from persistent necessity to remember password. These findings will augment development of novel implicit authentication system being transparent, easier, and unobtrusive for users.

Factor Analysis of Genetic Evaluations For Type Traits of Canadian Holstein Sires and Cows

  • Ali, A.K.;Koots, K.R.;Burnside, E.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.5
    • /
    • pp.463-469
    • /
    • 1998
  • Factor analysis was applied as a multivariate statistical technique to official genetic evaluations of type classification traits for 1,265,785 Holstein cows and 10,321 sires computed from data collected between August 1982 and June 1994 in Canada. Type traits included eighteen linear descriptive traits and eight major score card traits. Principal components of the factor analysis showed that only five factors explain the information of the genetic value of linear descriptive traits for both cows and sires. Factor 1 included traits related to mammary system, like texture, median suspensory, fore attachment, fore teat placement and rear attachment height and width. Factor 2 described stature, size, chest width and pin width. These two factors had a similar pattern for both cows and sires. In constrast, Factor 3 for cows involved only bone-quality, while in addition for sires, Factor 3 included foot angle, rear legs desirability and legs set. Factor 4 for cows related to foot angle, set of rear leg and leg desirability, while Factor 4 related to loin strenth and pin setting for sires. Finally, Factor 5 included loin strength and pin setting for cows and described only pin setting for sires. Two factors only were required to describe score card traits of cows and sires. Factor 1 related to final score, feet and legs, udder traits, mammary system and dairy character, while frame/capacity and rump were described by Factor 2. Communality estimates which determine the proportion of variance of a type trait that is shared with other type traits via the common factor variant were high, the highest ${\geq}$ 80% for final score, stature, size and chest width. Pin width and pin desirability had the lowest communality, 56% and 37%. Results indicated shifts in emphasis over the twelve-year period away from udder traits and dairy character, and towards size, scale and width traits. A new system that computes fmal score from type components has been initiated.

A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters (단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

A Study on Development of SVC to Improve Harmonics and Power Factor of Power Plant (발전소 소내전력 고조파 및 역률 개선용 SVC 개발에 관한 연구)

  • Yun, Gwang-Hee;Lee, Hee-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2109-2118
    • /
    • 2011
  • The power system has to maintain its synchronism from transient disturbances and oscillations. To achieve this, the static var compensator(SVC), which is a flexible AC transmission system(FACTS), is applied to the power system. SVC using an advanced control algorithm improves the stability of power system. This paper is a study on design of SVC to improve harmonics and power factor of power plant. The proposed SVC analyzes harmonics, voltage drop and reactive power in real time. On the basis of the analysis of the data, the SVC using a switching control algorithm decreases harmonic signals and increases the power factor. The experimental results show that the proposed SVC enhances the stability of power system.