• Title/Summary/Keyword: System

Search Result 273,270, Processing Time 0.125 seconds

회전체 기계전단을 위한 Hybrid 진단 시스템

  • 박홍석;강신현;이재종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.852-855
    • /
    • 1995
  • In modern plant lndustry, dignosis system is an essential implement because a human operator cannot check the state of system all the time. The recent facility needs a computer system which is able to replace and extense the function of the human expert. Checking the state of the plant system, the computer system uses signals form sensors attached to the plant systems. But, It is difficult to predict the cause of the failure from the sensing signals. Because the relationship among the signals cannot be easily represented by mathematical models. So expert system based on a fuzzy rule and Neural network method is sugguested. Expert system decide whether aa state of the system is ordinary of failure by the evaluation of the signals. If the state of the system is unstable, expert system preprocess the signals. When fault is occurred in the machine, the expert system dignoses the state of the system and find the cause as a primary tool. If the expert system dose not find the adequate cause successfully, neural network system uses the preprocessed signals as an input and propose a cause of the failure.

  • PDF

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

A Feasibility Study on the Mixed System of RC Columns and Steel Girders (콘크리트 기둥과 철골 보로 이루어진 복합구조의 적용성에 관한 연구)

  • 윤상문;김원태;최광호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.508-514
    • /
    • 1997
  • RCS system consists of RC columns and Steel girders. Because RC columns are useful for compression and steel girders are for bending moment, RCS system has good structural performances. This system, however, has had no verification in the onstruction fields. This paper is a feasibility study on RCS system to verify the structural and economic efficiency of RCS system. On this study, we analyze 18 models selected by existing building data survey, and design these models as steel system,SRC system (Steel + RC system) and RCS system. To verify the economic efficiency of RCS system, we estimate the columns of these models. And we predict the construction procedure of RCS system to compare construction duration of RCS system with others So, in this study we find that RCS system is more economic than steel system and SRC system.

  • PDF

Evaluation of the Reliability of Distribution Power Systems Considering Composite Customer Interruption Cost

  • Choi Sang-Bong;Nam Kee-Young;Kim Dae-Kyeong;Jeong Seong-Hwan;Lee Jae-Duk;Ryoo Hee-Suk
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.286-292
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using composite interruption cost. This paper presents algorithms to evaluate the interruption cost of distribution power systems by taking into consideration the failure source and the composite customer interruption cost. From the consumer's standpoint, the composite customer interruption cost is considered as the most valuable index to estimate the reliability of a power distribution system. This paper presents new algorithms that consider the load by customer type and failure probability by distribution facilities while calculating the amount of unserved energy by customer type. Finally, evaluation results of unserved energy and system interruption cost based on composite customer interruption cost are shown in detail.

A study on the development of Logistic Support system (군수 지원시스템 개발 방법에 관한 연구)

  • 신주환;전완수;김형렬
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.166-172
    • /
    • 1999
  • Weapon system is defined as a combination of primary system and logistics support system which are evaluated by capability and operational availability respectively. Weapon system developer thought that primary system was weapon system and also only primary system was important. Recent comparison of total life cycle cost showed that logistics support system was proved to be more important than primary system. However, until now no systematic approach to logistics support system development have applied in the area of developing support system and much money was exhausted by wrong logistics support system. We need to construct a universal metric for effectiveness of logistics support system and to cut out whatever activities or support elements which do not contribute to the metrics. This study describes a new approach under the name function approach to logistics support system development and also classifies five factors of failure frequency, stock out of frequency, administrative delay time, active repair time and logistic delay time that have influence on operational availability of logistics support system.

  • PDF

A Study on the Fisheries Control System of the Fisheries Act of Korea (수산관련법상(水產關聯法上) 어업관리제도(漁業管理制度)에 관한 연구(硏究))

  • Lee, Zong-Keun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.11 no.1
    • /
    • pp.1-23
    • /
    • 1999
  • The fisheries control system being now enforced in all countries may be generally classified as three types - the input control system, the output control system, and the technical control system. In Asian countries that have relatively small fishery scales, diverse object species and the fisheries resources has been regarded as "governmental possessions", fisheries have been controled subsidiarily using the technical control system based on the input control system traditionally. While in Europe and America that have relatively large fisheries scales, simple object species and the fisheries resources has been regarded as "common property", fisheries have been controled subsidiarily using the input control system and the technical control system based on the output control system. In Korea, fisheries have been controled subsidiarily using the technical control system based on the input control system traditionally, nevertheless overexplotation and overcapitalization have not been solved. Recently the EEZ was promulgated, the total allowable catch system was introduced to control the EEZ. But the output control system is totally different from the input control system of the Korea traditional fisheries system, simultaneous availableness of both system is considerably difficulty. Therefore a study on new systems to make both systems harmonized has to be performed. The thesis is aimed at presenting the general improvement direction of the Korea fisheries control system as the basis for establishment of the new fisheries control system.

  • PDF

Research on Information Portal Affordances and System Literacy of Cultural Artists: Focusing on Fuzzy Set Qualitative Comparative Analysis (문화예술인의 정보포털 어포던스 및 시스템 리터러시에 대한 연구: 퍼지셋 질적비교 분석을 중심으로)

  • Hyeon Yeong Kim;Hwan Soo Lee
    • Journal of Information Technology Services
    • /
    • v.22 no.6
    • /
    • pp.55-70
    • /
    • 2023
  • This study conducted a fuzzy set qualitative comparative analysis study on culture and arts information portals to ensure practical and universal use and activation of culture and arts information portals. The capabilities and influence of affordances and system literacy according to user experience regarding accessibility to cultural arts information portals are as follows. First, physical affordances in the culture and arts information portal were key conditions for the culture and arts information portal user experience regarding system accessibility, system understandability, system usability, system usability, and system literacy. Second, the functional affordance of the user experience in the cultural arts information portal was relatively low and unimportant, and when the functional affordance was low, the user's system accessibility, system understanding, system usefulness, system usability, and system literacy were increased. Third, if the user's functional affordance and sensory affordance are low in the culture and arts information portal, the system accessibility, system understanding, system usability, and system literacy of the culture and arts information portal users are increased. Fourth, cultural arts information portals must build an innovative system with a systematic approach appropriate for the user base by linking system literacy capabilities with a focus on physical affordances.

A Study on the Operation Strategies of Multi-Infeed HVDC System in Jeju Island Power System (제주지역 계통특성을 고려한 다기(Multi-Infeed) HVDC 시스템 운전 방안에 관한 연구)

  • Lee, Seung-Yeup;Yoon, Min-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1675-1681
    • /
    • 2017
  • As recently the demand on electric power has been increasing, the requirement of power supply reliability has been increased. Accordingly, the number of HVDC transmission systems in the world has been steadily increased, which have been installed in the power system to transmit a large capacity power to the long distant and interconnect the power grid between different countries. etc. #1 HVDC Transmission System was installed between Haenam and Jeju island in 1998, which is the first HVDC system furnished in korea. and has been operated until now. Before #1 HVDC Transmission System being installed, the power system of the Jeju Island is a isolated power system from that of Korea mainland. After the construction of #1 HVDC the system has made the Jeju power system more reliable and also been able to supply the mainland power, which was cheaper than that of Jeju island, to Jeju island. The construction of additional HVDC transmission system between mainland and the Jeju Island has been currently underway to cope with recent changes of the power market of the Jeju island, for examples the increase of power demand and the capacity of wind power generation. etc. #2 HVDC Transmission System construction was completed in 2012. #3 HVDC Transmission System will be also installed according to the plan. If all goes as planned, the Jeju power system will be operated with Multi-Infeed HVDC system connected to mainland power system. So the additional studies are needed in order to maintain the stability of the Jeju power system and get the efficiency of the Multi-Infeed HVDC system. Therefore, in this paper, the optimal operation strategies of the Multi-Infeed HVDC system between the mainland of Korea and the Jeju are suggested to ensure the stability of the power system in Jeju Island when the Multi-Infeed HVDC system is operated between two power system.

System Identification of a Building Structure Using Wireless MEMS System (무선 MEMS 시스템을 이용한 구조물 식별)

  • Kim, Hong-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • The structural health monitoring has been gaining more importance in civil engineering areas such as earthquake and wind engineering. The use of health monitoring system can also provide tools for the validation of structural analytical model. However, only few structures such as historical buildings and some important long bridges have been instrumented with structural monitoring system due to high cost of installation, long and complicated installation of system wires. In this paper, the structural monitoring system based on cheap and wireless monitoring system is investigated. The use of advanced technology of micro-electro-mechanical system(MEMS) and wireless communication can reduce system cost and simplify the installation. Further the application of wireless MEMS system can provide enhanced system functionality and due to low noise densities. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS system estimates system parameters accurately.

On-line System Identification using State Observer

  • Park, Duck-Gee;Hong, Suk-Kyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2538-2541
    • /
    • 2005
  • This paper deals one of the methods of system identification, especially on-line system identification in time-domain. The algorithm in this study needs all states of the system as well input to it for system identification. In this reason, Kalman filter is used for state estimation. But in order to implement a state estimator, the fact that a system model must be known is logical contradiction. To overcome this, state estimation and system parameter estimation are performed simultaneously in one sample. And the result of the system parameter estimation is used as basis to state estimation in next sample. On-line system identification comes, in every sample by performing both processes of state estimation and parameter estimation that are related mutually and recursively. This paper demonstrates the validity of proposed algorithm through an example of an unstable inverted pendulum system. This algorithm can be useful for on-line system identification of a system that has fewer number of measurable output than system order or number of states.

  • PDF