• Title/Summary/Keyword: Synthetic temperature

Search Result 810, Processing Time 0.027 seconds

Temperature Effect in the process of DAF as pretreatment of SWRO (해수담수화 전처리로서 DAF공정에서 고온의 해수에 대한 영향 특성)

  • Park, Hyunjin;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.807-813
    • /
    • 2012
  • Flocculation and flotation are used as pretreatment steps prior to the reverse osmosis (RO) process. During seawater treatment, high temperature can change the water chemistry of seawater during the process of coagulation. It also affects bubble volume concentration (BVC) and bubble characteristics. Coagulants such as alum and ferric salts at $40^{\circ}C$ can also change flux rates in the seawater reverse osmosis (SWRO) process. In this study, the bubble characteristics in dissolved air flotation (DAF), used as a SWRO pretreatment process, were studied in synthetic seawater at $20^{\circ}C$ and $40^{\circ}C$. The flux of an RO membrane was monitored after dosing the synthetic seawater with coagulants at different temperatures. Results showed that BVC increases as the operating pressure increases and as the salt concentration decreases. The bubble size released at $40^{\circ}C$ is far smaller than that at $20^{\circ}C$The addition of a ferric salt is effective for turbidity removal in synthetic seawater at $20^{\circ}C$; it is more effective than alum. When synthetic seawater was dosed with a ferric salt, the RO membrane flux increased by 27 % at $40^{\circ}C$.

Development of Synthetic Regression Diagram for Analyzing Linear Trend of Sea Surface Height, Temperature, and Salinity around the Korean Marginal Seas (한반도 주변 해역 해수면 및 수온, 염분의 선형 추세 분석을 위한 종합 회귀 도표 개발)

  • LIM, BYEONG-JUN;CHANG, YOU-SOON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.21 no.2
    • /
    • pp.67-77
    • /
    • 2016
  • This study developed synthetic regression diagram for analyzing the linear trend of sea surface height, temperature, and salinity around the Korean marginal seas. In situ observed data had been quality controlled and they were verified by EOF comparison with objective analyzed data. From the synthetic regression diagram, we confirmed similar linear regression values with those of previous studies, but additionally provided detailed regression rate of each 5 to 30 year for the total periods of 1983-2013. We expect that quantitative results presented by this study will be useful as standard reference numbers for relevant studies analyzing oceanic long-term trend.

Viscosity Prediction of Synthetic Lubricants from Temperature and Pressure Dependence of Dielectric Relaxation Time

  • Suzuki, A.;Masuko, M.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.355-356
    • /
    • 2002
  • The dielectric permittance and the dielectric loss factor of several lubricating oils were measured at frequencies from 100 Hz to 1.5 MHz. The measurements were carried out under atmospheric pressure as a function of temperature and under fixed temperature as a function of pressure. Temperature and pressure dependence of dielectric relaxation time were investigated. The temperature dependence of relaxation time obeyed the Vogel-Fulcher-Tammann (VFT) law. We modified the VFT equation in order to express the dielectric relaxation time as a function of temperature and pressure. Furthermore. by taking into consideration the similarity of the temperature and pressure dependence between dielectric relaxation and mechanical relaxation. the prediction of high-pressure viscosity were conducted. The predicted results were compared with the viscosity data obtained from the falling-sphere type viscometer.

  • PDF

Generation and Verification on the Synthetic Precipitation/Temperature Data

  • Oh, Jai-Ho;Kang, Hyung-Jeon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2016.09a
    • /
    • pp.25-28
    • /
    • 2016
  • Recently, because of the weather forecasts through the low-resolution data has been limited, the demand of the high-resolution data is sharply increasing. Therefore, in this study, we restore the ultra-high resolution synthetic precipitation and temperature data for 2000-2014 due to small-scale topographic effect using the QPM (Quantitative Precipitation Model)/QTM (Quantitative Temperature Model). First, we reproduce the detailed precipitation and temperature data with 1km resolution using the distribution of Automatic Weather System (AWS) data and Automatic Synoptic Observation System (ASOS) data, which is about 10km resolution with irregular grid over South Korea. Also, we recover the precipitation and temperature data with 1km resolution using the MERRA reanalysis data over North Korea, because there are insufficient observation data. The precipitation and temperature from restored current climate reflect more detailed topographic effect than irregular AWS/ASOS data and MERRA reanalysis data over the Korean peninsula. Based on this analysis, more detailed prospect of regional climate is investigated.

  • PDF

Study on Shortening Light-Off Time of Three Way Catalyst and Reduction of Harmful Emissions with Exhaust Synthetic Gas Injection(ESGI) Technology during Cold Start of SI Engines (가솔린 기관의 냉간시동 조건에서 합성가스 배기분사 기술에 의한 촉매의 활성화 온도 도달시간 단축 및 유해배출물 저감에 관한 연구)

  • Cho, Yong-Seok;Lee, Seang-Wock;Won, Sang-Yeon;Song, Chun-Sub;Park, Young-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.94-101
    • /
    • 2008
  • Since regulations of exhaust emissions are continuously reinforced, studies to reduce harmful emissions during the cold start period of SI engines have been carried out very extensively worldwide. During the cold start period, raising the temperature of cold exhaust gas is a key strategy to minimize the light-off time of three way catalysts. In this study, a synthetic gas containing a large amount of hydrogen was injected into the exhaust manifold to raise the exhaust gas temperature and to reduce harmful emissions. The authors tried to evaluate changes in exhaust gas temperature and harmful emissions through controlling the engine operating parameters such as ignition timings and lambda values. Also the authors investigated both combustion stability and reduction of harmful emissions. Experimental results showed that combustion of the synthetic gas in the exhaust manifold is a very effective way for solving the problems of harmful emissions and light-off time. The results also showed that the strategy of retarded ignition timings and increased air/fuel ratios with ESGI is effective in raising exhaust gas temperature and reducing harmful emissions. Futhermore, the results showed that engine operating parameters ought to be controlled to lambda = 1.2 and ignition timing = $0{\sim}3^{\circ}$ conditions to reduce harmful emissions effectively under stable combustion conditions.

Synthetic Circumstantial Judgement System Applied Recognition of Fire Levels Model (화재 상황 인식 모델을 적용한 종합 상황 판단 시스템)

  • Song, Jae-Won;Lee, Se-Hee;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1275-1281
    • /
    • 2011
  • This paper presents synthetic circumstantial judgement system that detects and predicts a fire in subway station. Unlike conventional fire surveillance systems that judge the fire or not through smoke, CO, temperature or variation of temperature, a proposed system discovers a fire more easily or gives the alarm high possibility of fire to operator through recognition of fire levels based on Fuzzy Inference System using by FCM and information of objects from video data.

  • PDF

A Study on the Effect of Cooled Water-Soluble-Cutting Fluids on the Machinability (수용성 절삭유제의 냉각성이 피삭성에 미치는 영향에 관한 연구)

  • 김정두
    • Tribology and Lubricants
    • /
    • v.4 no.2
    • /
    • pp.52-59
    • /
    • 1988
  • The purpose of this study is to establish a standard for proper selection of water soluble cutting fluids, such as Emulsion type, Semi-Synthetic type and synthetic type, by investigating cutting effects at the normal temperature(26$\circ$C) and cooling temperature(0$\circ$C) from the viewpoint of cooling and lubricant actions. This paper describes a relation among cutting force, surface roughness and cooled water soluble cutting fluids which are considered as effective restraints on Built up edge.

Effect of Temperature and Water Assumtion on Strength of Spot Welded Zine Steel Plates (점용접 아연도금판의 강도특성에 대한 온도 및 침수의 영향)

  • Seo, Do-Won;Yoon, Ho-Chel;Choi, Jun-Yong;Lim, Jae-Kyoo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.358-363
    • /
    • 2003
  • Spot welded structure is operated in diverse situation because of temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase, But spot welded structure strength is affected by dampness and environment temperatures. Therefore, it is important to evaluate effect of temperature of spot welded part, In this study, the strength distribution of spot welded plates is evaluated about the environmental temperature of zine coated steel plates and test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000hours to evaluate the effects of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and $50^{\circ}C$. Strength is evaluated by tensile-shear test. The conditions of spot welding are 240kgf electrode force, 10KA welding current with 0 and 5mm clearance. From this study, spot welded specimens with clearance have lower tensile-shear strength in the distilled water or synthetic sea water comparing with spot welded specimens without clearance. And they have lower tensile-shear strength under $-40^{\circ}C$ and over $50^{\circ}C$.

  • PDF

Thermal Destruction of Waste Insulating Oil Containing PCBs under High Temperature and Pressurized Conditions

  • Seok, Min-Gwang;Lee, Gang-Woo;Lee, Jae-Jeong;Kim, Min-Choul;Kim, Yang-Do;Jung, Jong-Hyeon;Shon, Byung-Hyun
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.157-165
    • /
    • 2012
  • This experimental study was performed to obtain thermal energy from the combustion of synthetic gas, produced by the pyrolysis of insulating oil containing polychlorinated biphenyls (PCBs) in a high temperature and high pressure reactor. The average synthetic gas generated was $59.67Am^3/hr$ via the steady state gasification of insulating oil waste (20 kg/hr) with average concentrations (standard deviation) of $CO_2$, CO, and $H_2$ in the synthetic gas of $38.63{\pm}3.11%$, $35.18{\pm}1.93%$, and $28.42{\pm}1.68%$, respectively. The concentrations of the PCBs in the transformer insulating oil and synthetic gas after its gasification, and the concentrations of the dioxins that could be produced from the incomplete degradation of PCBs were measured. It was revealed that the PCBs in the insulating oil were composed of the series from tetrachlorobiphenyl to octachlorobiphenyl. However, only the #49, #44, #52, and #47/75/48 congeners were detected from the synthetic gas after gasification of the insulating oil and in the flue gas from the combustor. In conclusion, the experimental conditions suggested in this study were very useful for the appropriate treatment of insulating oil containing PCBs. Also, fuel gas containing CO and $H_2$ can be obtained from the pyrolysis of insulating oil containing PCBs.

Hydration Heat Characteristics of Concrete with Synthetic Resin Form in Hot Weather Circumstance (서중환경 시 합성수지 거푸집 적용 콘크리트 수화열 특성)

  • Nam, Kyung-Yong;Kim, Seong-Deok;Choi, Suk;Yoo, Jung-Il
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.129-130
    • /
    • 2020
  • This paper attempted to examine the characteristics of heat of hydration and calorific value of concrete according to the formwork material in Hot weather environment. As a result of the experiment, it was found that there were no problems such as temperature cracking and delay in hydration reaction when a synthetic resin form was used.

  • PDF