• 제목/요약/키워드: Synoptic weather

검색결과 212건 처리시간 0.021초

고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화 (Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea)

  • 김유라;윤일희;김희종
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

국지 기상 특성에 따른 군산, 대구 및 포항의 대기질의 일변화 (Variations of Air Quality in Kunsan, Taegu, and Pohang due to the Characteristics of Local Weather)

  • 서기수;윤일희
    • 한국환경과학회지
    • /
    • 제6권6호
    • /
    • pp.613-628
    • /
    • 1997
  • Diurnal variations of air quality due to the characteristic features of local weather phenomena over Kunsan, Taegu, and Pohang are analyzed using various synoptic wand fields and the characteristics of local weather during the period of 1990 to 1992. The air pollutants analyzed are sulfur dioxide($SO2_$), nitrogen dioxide($NO_2$), and oxidants ($0_3$). The synoptic wind fields estimated at over the 850 hPa geopotential height are divided in terms of four wand directions and two wand speed categories for each season. The synoptic weather conditions are also classified Into two categories depending on the 850 hPa cloud amounts. The present study shows that the $SO_2$ concentration over Kunsan, and Taegu was maximum at the two or three hours after sunrise and second primary was three or flour hours after sunset. On the other hand, Its concentration over Kunsan was malnmum at 1900 LST or 2000 LST The $O_3$ concentration over the three cities shows Its mapdmum In the afternoon when the solar radiation is strong. The $NO_2$ concentration over Kansan shows in reverse proportion to the $O_3$ concentration over the Kunsan.

  • PDF

종관바람장에 따른 대구시의 계절별 대기질의 일변화 (Diurnal Variations of Air Quality under the Various Synoptic Wind Fields for Each Season over Taegu City)

  • 송은영;윤희경
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.113-130
    • /
    • 1996
  • Diurnal variations of air quality for each season over Taeau city were analyzed using the characteristic features of the various synoptic wind fields. The air quality data which were monitored by four stations are the hourly averaged sulfur dioxide($SO_2$), total suspended particulate(TSP) and oxidants ($O_3$) during the period of 1989 to 1992. The various synoptic wind fields obtained from the 850 hPa geopotential height were divided in to four geostrophic wind directions and two geostrophic wind speeds for each seasons. The synoptic weather conditions were again subdivided info two categories using the lotal cloud amounts, The results shows that diurnal and seasonal variations of the air quality over Taegu city, such as sulfur dioxide, total suspended particulate and oxidants reseal the various characteristics under the same synoptic weather conditions.

  • PDF

Dominant Synoptic Patterns Controlling PM10 Spatial Variabilities over the Korean Peninsula

  • Park, Hyo-Jin;Wie, Jieun;Moon, Byung-Kwon
    • 한국지구과학회지
    • /
    • 제40권5호
    • /
    • pp.476-486
    • /
    • 2019
  • This study examines the controlling role of synoptic disturbances on $PM_{10}$ spring variability in the Korean Peninsula by using empirical orthogonal function (EOF) and back trajectory analyses. Three leading EOF modes are identified, and a lead-lag analysis suggests that $PM_{10}$ variabilities be closely related to the synoptic weather systems. The first EOF shows the spatially homogeneous distribution of $PM_{10}$, which is influenced by travelling anticyclonic disturbance with negative precipitation and descending motion. The second and third modes exhibit the dipole structures of $PM_{10}$, being associated with propagating cyclones. Furthermore, the back-trajectory analysis suggests that the transport of pollutants by anomalous winds associated with synoptic disturbances also contribute to the altered $PM_{10}$ concentration. Hence, a substantial synoptic control should be considered in order to fully understand the $PM_{10}$ spatiotemporal variability.

2017년 1월 20일 발생한 강원 영동대설 사례에 대한 대기의 구조적 특성 연구 (A Study on the Synoptic Structural Characteristics of Heavy Snowfall Event in Yeongdong Area that Occurred on 20 January, 2017)

  • 안보영;이정선;김백조;김희원
    • 한국환경과학회지
    • /
    • 제28권9호
    • /
    • pp.765-784
    • /
    • 2019
  • The synoptic structural characteristics associated with heavy snowfall (Bukgangneung: 31.3 cm) that occurred in the Yeongdong area on 20 January 2017 was investigated using surface and upper-level weather charts, European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis data, radiosonde data, and Moderate Resolution Imaging Spectroradiometer (MODIS) cloud product. The cold dome and warm trough of approximately 500 hPa appeared with tropopause folding. As a result, cold and dry air penetrated into the middle and upper levels. At this time, the enhanced cyclonic potential vorticity caused strong baroclinicity, resulting in the sudden development of low pressure at the surface. Under the synoptic structure, localized heavy snowfall occurred in the Yeongdong area within a short time. These results can be confirmed from the vertical analysis of radiosonde data and the characteristics of the MODIS cloud product.

겨울철 고기압 영향에서 도로 위 기상요소와 노면정보 변화 특성에 관한 연구 (Characteristics of Road Weather Elements and Surface Information Change under the Influence of Synoptic High-Pressure Patterns in Winter)

  • 김백조;남형구;김선정;김건태;김지완;이용희
    • 한국환경과학회지
    • /
    • 제31권4호
    • /
    • pp.329-339
    • /
    • 2022
  • Better understanding the mechanism of black ice occurrence on the road in winter is necessary to reduce the socio-economic damage it causes. In this study, intensive observations of road weather elements and surface information under the influence of synoptic high-pressure patterns (22nd December, 2020 and 29th January, and 25th February, 2021) were carried out using a mobile observation vehicle. We found that temperature and road surface temperature change is significantly influenced by observation time, altitude and structure of the road, surrounding terrain, and traffic volume, especially in tunnels and bridges. In addition, even if the spatial distribution of temperature and road surface temperature for the entire observation route is similar, there is a difference between air and road surface temperatures due to the influence of current weather conditions. The observed road temperature, air temperature and air pressure in Nongong Bridge were significantly different to other fixed road weather observation points.

Long-range Transport Mechanisms of Asian Dust associated with the Synoptic Weather System

  • Kim, Yoo-Keun;Lee, Hwa-Woon;Moon, Yun-Seob;Song, Sang-Keun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제10권S_4호
    • /
    • pp.197-206
    • /
    • 2001
  • The long-range transport mechanisms of Asian dust were analyzed based on the synoptic weather system and numerical simulation by using NCEP/NCAR reanalysis and TOMS data during the periods of 1996-2001. We classified the whole weather types of eastern Asia during spring and created the representative weather types during the yellow sand events using cluster analysis and weather charts for the last 6 years(1996~2001). These long-range transport mechanisms were related to various pressure patterns including high and low, trough and ridge, and upper-level fronts. Case studies of the yellow sand events have performed by the simulation of MM5 with meteorological elements such as the horizontal wind of u and v component, potential temperature, potential vorticity, and vertical circulation during the episodic days(2~8 March 2001). In addition, the origin of the long-range transport was examined with the estimation of backward trajectory using HYSPLIT4 Model. In this paper, we concluded that three weather types at 1000 hPa, 850 hPa, 500 hPa, and 300 hPa levels were classified respectively. The dominant features were the extending continental outflow from China to Korea at 1000 hPa and 850 hPa levels, the deep trough passage and cold advection at 500 hPa and 300 hPa levels during the yellow sand events. And also, we confirmed the existence of pola $r_tropical jets in the upper-level, the behavior of potential vorticity over Korea, the estimation of potential vorticity through vertical cross section, and the transport of yellow sand through backward trajectories.es.

  • PDF

종관 지상 자료를 이용한 TOVS수치 해석 산출 자료 (TOVS retrieved data with the real time synoptic surface data)

  • 주상원;정효상;김금란
    • 대한원격탐사학회지
    • /
    • 제10권1호
    • /
    • pp.55-67
    • /
    • 1994
  • The International TOVS(TIROS Oprational Vertical Sounders) Process Package(ITPP-VI)is for a global usage, which needs a surface data to generate atmospheric soundings. If the initial input process in the ITPP-VI is not modified, it takes climatic surface data for producing sounding data in general. Korea Meteorological Administration(KMA) is trying to improve the quality of TOVS sounding data using real-time synoptic observations and make a use weather prediction and analysis in various ways. Serval cases in this study show that TOVS retrieved meteolorogical parameters such as atmopheric temperature, dew point depression and geopotential heights used by synoptic surface observations can delineate more detailed atmospheric feature rather than those used by climate surface data. In addition, the collocated comparisons of TOVS synoptic retrieved parameters with radiosonde observations are performed statistically. TOVS retrieved fields with the synoptic surface analyzed data show smaller bias reatively than those with the climatic data and also reduced root mean square differences below 700 hPa as expected.

관측과 모델 자료를 활용한 겨울철 영동지역 한기 축적(Yeongdong Cold Air Damming; YCAD)의 공간 규모 분석 (An Analysis on the Spatial Scale of Yeongdong Cold Air Damming (YCAD) in Winter Using Observation and Numerical Weather Model)

  • 남형구;정종혁;김현욱;심재관;김백조;김승범;김병곤
    • 대기
    • /
    • 제30권2호
    • /
    • pp.183-193
    • /
    • 2020
  • In this study, Yeongdong cold air damming (YCAD) cases that occur in winters have been selected using automatic weather station data of the Yeongdong region of Korea. The vertical and horizontal scales of YCAD were analyzed using rawinsonde and numerical weather model. YCAD occurred in two typical synoptic patterns such that low pressure and trough systems crossing and passing over Korea (low crossing type: LC and low passing type: LP). When the Siberian high does not expand enough to the Korean peninsula, low pressure and trough systems are likely to move over Korea. Eventually this could lead to surface temperature (3.1℃) higher during YCAD than the average in the winter season (1.6℃). The surface temperature during YCAD, however, was decrease by 1.3℃. The cold air layer was elevated around 120 m~450 m for LP-type. For LC-type, the cold layer were found at less than approximately 400 m and over 1,000 m, which could be thought of combined phenomena with synoptic and local weather forcing. The cross-sectional analysis results indicate the accumulation of cold air on the east mountain slope. Additionally, the north or northeasterly winds turned to the northwesterly wind near the coast in all cases. The horizontal wind turning point of LC-type was farther from the top of the mountain (52.2 km~71.5 km) than that of LP-type (20.0 km~43.0 km).

분 단위 강우자료의 품질 개선방안에 관한 연구 (A Study on Quality Control Method for Minutely Rainfall Data)

  • 김민석;문영일
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.319-326
    • /
    • 2015
  • 수자원 설계 및 홍수 예 경보 등을 위한 수문분석 시, 강우자료는 필수요소이다. 현재 수문분석 시 비교적 장기간의 자료를 보유하고 있는 기상청, 국토교통부 등의 지상기상관측지점(SSS, Surface Synoptic Stations)에 시 강우자료를 이용하고 있으나, 집중호우가 빈번히 발생하는 현실정과 집중호우의 발생빈도가 증가할 것으로 예상되는 향후에는 더욱 조밀한 관측망을 구성하고 있는 방재기상관측지점(AWS, Automatic Weather Stations)의 분 단위 강우자료를 이용한 분석이 필요하다. 그러나 방재기상관측지점의 분 단위 강우자료는 자동으로 관측되고 있어, 자료품질에 대한 문제점이 매번 지적되고 있다. 본 연구에서는 서울지역을 중심으로 기상청 방재기상관측지점의 분 단위 강우자료의 품질개선 방안에 관한 연구를 실시하였다. 분 단위 강우자료의 품질관리방안은 크게 3단계로 결측치 품질관리, 이상치 품질관리 그리고 강우 보완 품질관리로 구분하여 품질관리 방안을 제시하고 분석을 수행하였다. 마지막으로 서울지점의 분 단위 강우자료와 시 단위 강우자료의 비교분석을 통해 강우 품질관리에 대한 평가를 실시하였다. 이는 향후 분 단위 강우자료를 이용한 수문분석 시, 강우자료 품질관리 방안으로 활용될 것으로 판단된다.