• 제목/요약/키워드: Synchronous Controller

검색결과 652건 처리시간 0.031초

동적전압보상기의 전압제어를 위한 PLL 방식의 개선 (Improvement of PLL Method for Voltage Control of Dynamic Voltage Restorer)

  • 김병섭;최종우
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.936-943
    • /
    • 2009
  • Dynamic voltage restorer(DVR) is now more preferable enhancement than other power quality enhancement in industry to reduce the impact of voltage faults, especially voltage sags to sensitive loads. The main controllers for DVR consists of PLL(phase locked loop), compensation voltage calculator and voltage compensator. PLL detects the voltage faults and phase. Compensation voltage calculator calculates the reference voltage from the source voltage and phase. With calculated compensation voltage from PLL, voltage compensator restores the source voltage. If PLL detect ideal phase, compensation voltage calculator calculates ideal compensation voltage. Therefore, PLL for DVR is very important. This paper proposes the new method of PLL in DVR. First, the power circuit of DVR system is analyzed in order to compensate the voltage sags. Based on the analysis, new PLL for improving transient response of DVR is proposed. The proposed method uses band rejection filter(BRF) at q-axis in synchronous flame. In order to calculate compensation voltage in commercial instruments, the PQR theory is used. Proposed PLL method is demonstrated through simulation using Matlab-Simulink and experiment, and by checking load voltage, confirms operation of the DVR

한계계단 응답특성을 이용한 영구자석형 동기전동기 속도제어 (Speed Control of Permanent Magnet Synchronous Motor using Limited Step Response Characteristics)

  • 전인효;최중경;박승엽
    • 한국정보통신학회논문지
    • /
    • 제2권3호
    • /
    • pp.295-302
    • /
    • 1998
  • 본 논문에서는 한계계단 응답특성을 이용하여 영구자석헝 동기전동기의 속도 제어계에 대한 새로운 자동동조 PI(Proportional Integral) 제어기를 설계하였다. 과도응답 기간동안 소위 한계입력이라고 하는 계단입력을 인가하여 Pㅑ 제어기의 자동동조를 위한 정보를 얻기 위한 기법을 제안한다. 시스템 파라메터 추정과 동시에 속도제어가 온라인으로 이루어지는데, 이것은 시스템의 불확실성에도 불구하고 한계입력에 의해서 얻어진 시스템 파라메터 정보가 연속적으로 PI 제어기에 적용될 수 있다는 것이다. 제안된 자동동조 알고리즘은 단조증가 계단응답 특성을 갖는 영구 자석형 동기전동기의 속도제어에 대한 시뮬레이션과 실험결과를 통하여 그 유효함을 확인하였다.

  • PDF

PMLSM의 개선된 초기 자극위치 추정방법 (Advanced Method for an Initial Pole Position Estimation of a PMLSM)

  • 이진우
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.124-129
    • /
    • 2005
  • 본 논문에서는 서보분야에 적용되는 고분해능 엔코더를 장착하고 자극위치 센서인 홀센서를 부착하지 않은 선형영구자석 동기전동기의 개선된 초기 자극위치 추정방법을 제안하였다. 제안한 방법은 수치해석법인 할선법을 적용하여 추력이 영인 두 곳 중에서 한 곳을 추정하고, 추정 q축에 시험전류를 인가하여 실제 전동기의 d축을 추정한다. 그리고 전류제어기와 위치정보만을 사용하는 제안한 추정방법은 적용이 용이한 장점을 가지며, 회전형 동기전 동기에도 쉽게 적용할 수 있다. PMLSM에 대한 실험을 통하여 매우 짧은 이동거리(약 평균 85㎛)내에서 빠른 시간 안에 높은 초기각 추정 정밀도를 보이는 우수한 실험결과를 제시하여 제안한 방법의 타당성을 검증하였다.

Low-frequency Vibration Suppression Control in a Two-mass System by Using a Torque Feed-forward and Disturbance Torque Observer

  • Li, Qiong;Xu, Qiang;Wu, Ren
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.249-258
    • /
    • 2016
  • Given that elastic connection is often used between motor drives and load devices in industrial applications, vibration often occurs at the load side. Vibration suppression is a crucial problem that needs to be addressed to achieve a high-performance servo-control system. Scholars have presented many strategies to suppress vibration. In this study, we propose a method to diminish vibration by using a torque feed-forward and disturbance torque observer. We analyze the system performance and explain the principle of the proposed vibration suppression method based on the transfer functions of the system. The design of controller parameters is another important issue in practical applications. We accordingly provide a succinct outline of the design specifications based on the coefficient diagram method. Furthermore, we build a model under the Simulink environment and conduct experiments to validate the proposed method. Results show that speed and position vibrations are successfully suppressed by the proposed method.

슬라이딩 모드 기반의 직접전력제어를 이용한 계통연계형 풍력발전 시스템의 LVRT 제어 (LVRT control of Grid-Connected Wind Turbine Using Sliding-Mode Based Direct Power Control)

  • 정해광;이교범
    • 전력전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.396-404
    • /
    • 2011
  • 본 논문은 불평형 전원사고 발생 시 계통연계형 풍력발전 시스템의 성능 개선을 위한 슬라이딩모드 기반의 직접전력제어기법을 제안한다. 제안하는 제어기법은 전류의 좌표변환 없이 시스템의 유, 무효 전력을 직접 제어함으로써 계통사고 시 빠른 응답특성을 가지고 별도의 동기위상각 정보를 필요로 하지 않으며, 불평형 사고 시 계통주파수의 2배에 해당하는 전력 리플이 발생하지 않으므로 계통연계형 풍력발전 시스템 제어에 적합하다. 시뮬레이션 및 실험 결과를 통해 제안하는 제어기법의 타당성과 강인성을 확인한다.

dSPACE 1104 시스템을 이용한 영구자석 동기전동기 벡터제어 구현 (Vector Control Implementation of PMSM Using dSPACE 1104 System)

  • 이용석;이동민;지준근;차귀수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1084-1085
    • /
    • 2007
  • This paper presents a vector control implementation for SPMSM(Surface-mounted Permanent Magnet Synchronous Motor) using dSPACE 1104 system and MATLAB/SIMULINK. SPMSM can be treated as a DC motor provided that currents of flux and torque component are controlled independently using vector control. Therefore various control algorithms for conventional DC motor control can be adopted to SPMSM. The system is designed to improve set-point tracking capability, fast response, and accuracy. In This paper, d-q equivalent modeling of PMSM is derived based on vector control theory. The PI controller is used for speed control and state feedback PI current control method is used for current control. For the implementation of high performance vector control system, dSPACE 1104 system is used. Simulations and experiments were carried out to examine validity of the proposed vector control implementation.

  • PDF

초정밀 자기부상 스테이지용 능동진동제어시스템 설계 (A Design Of Active Vibration Control System For Precise Maglev Stage)

  • 이주훈;김용주;손성완;이홍기;이세한;최영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.121-124
    • /
    • 2004
  • In this paper, we address an active vibration control system, which suppresses the vibration engaged by magnetically levitated stage. The stage system consists of a levitating platen with four permanent magnetic linear synchronous motors in parallel. Each motor generates vertical force fer suspension against gravity and propulsion force horizontally as well. This stage can generate six degrees of freedom motion via the vertical and horizontal forces. In the stage system, which represents the settling-time critical system. the motion of the platen vibrates mechanically. We designed an active vibration control system for suppressing vibration due to the stage moving. The command feedforward with inertial feedback algorithm is used fer solving stage system's critical problems. The components of the active vibration control system are accelerometers for detecting stage table's vibrations, a digital controller with high precise signal converters, and electromagnetic actuators.

  • PDF

A novel grey TMD control for structures subjected to earthquakes

  • Z.Y., Chen;Ruei-Yuan, Wang;Yahui, Meng;Timothy, Chen
    • Earthquakes and Structures
    • /
    • 제24권1호
    • /
    • pp.1-9
    • /
    • 2023
  • A model for calculating structure interacted mechanics is proposed. A structural interaction model and controller design based on tuned mass damping (TMD) was developed to control the induced vibration. A key point is to introduce a new analytical model to evaluate the properties of the TMD that recognizes the motion-dependent nonlinear response observed in the simulations. Aiming at the problem of increased current harmonics and low efficiency of permanent magnet synchronous motors for electric vehicles due to dead time effect, a dead time compensation method based on neural network filter and current polarity detection is proposed. Firstly, the DC components and the higher harmonic components of the motor currents are obtained by virtue of what the neural network filters and the extracted harmonic currents are adjusted to the required compensation voltages by virtue of what the neural network filters. Then, the extracted DC components are used for current polarity dead time compensation control to avert the false compensation when currents approach zero. The neural network filter method extracts the required compensation voltages from the speed component and the current polarity detection compensation method obtains the required compensation voltages by discriminating the current polarity. The combination of the two methods can more precisely compensate the dead time effect of the control system to improve the control performance. Furthermore, based on the relaxed method, the intelligent approach of stability criterion can be regulated appropriately and the artificial TMD was found to be effective in reducing cross-wind vibrations.

단일 마이크로컨트롤러 기반 다중 모터제어기 구현 (Implementation of Multi-Motor Controller Based on a Single Microcontroller)

  • 권재민;이경중;안현식
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권1호
    • /
    • pp.237-243
    • /
    • 2015
  • 본 논문에서는 다중 모터 기반 피드백 제어 시스템에 대하여 캐스케이드 형태의 제어기를 고려하고 제한된 ADC(Analog to Digital Converter) 자원을 효과적으로 이용하기 위한 자원 할당 방법을 제안한다. 이 방법의 목적은 한정된 ADC 자원으로 모터 위치 측정값의 오차 및 d-q 축 전류 측정값의 오차를 최소화하는 것이다. 다중 모터 기반 피드백 제어 시스템에 대한 캐스케이드 제어 구조는 속도 제어기와 전류제어기로 구성되며, 이러한 구조가 각 모터에 병렬로 적용되어 각 모터의 회전 속도가 독립적으로 제어된다. 다중모터제어기는 추가되는 마이크로컨트롤러 없이 오직 하나의 컨트롤러에 구현된다. 다수의 AC 모터로 구성된 실험환경과 제안된 제어구조 및 ADC 할당방법을 이용함으로써 각 모터의 속도 및 토크가 주어진 속도 지령값을 정밀하게 추종함을 보인다.

A Magnetic Energy Recovery Switch Based Terminal Voltage Regulator for the Three-Phase Self-Excited Induction Generators in Renewable Energy Systems

  • Wei, Yewen;Kang, Longyun;Huang, Zhizhen;Li, Zhen;Cheng, Miao miao
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1305-1317
    • /
    • 2015
  • Distributed generation systems (DGSs) have been getting more and more attention in terms of renewable energy use and new generation technologies in the past decades. The self-excited induction generator (SEIG) occupies an important role in the area of energy conversion due to its low cost, robustness and simple control. Unlike synchronous generators, the SEIG has to absorb capacitive reactive power from the outer device aiming to stabilize the terminal voltage at load changes. This paper presents a novel static VAR compensator (SVC) called a magnetic energy recovery switch (MERS) to serve as a voltage controller in SEIG powered DGSs. In addition, many small scale SEIGs, instead of a single large one, are applied and devoted to promote the generation efficiency. To begin with, an expandable mathematic model based on a d-q equivalent circuit is created for parallel SEIGs. The control method of the MERS is further improved with the objective of broadening its operating range and restraining current harmonics by parameter optimization. A hybrid control strategy is developed by taking both of the stand-alone and grid-connected modes into consideration. Then simulation and experiments are carried out in the case of single and double SEIG(s) generation. Finally, the measurement results verify that the proposed DGS with SVC-MERS achieves a better stability and higher feasibility. The major advantages of the mentioned variable reactive power supplier, when compared to the STATCOM, include the adoption of a small DC capacitor, line frequency switching, simple control and less loss.