• 제목/요약/키워드: Synchronous Control

검색결과 1,730건 처리시간 0.028초

형구자석형 동기정동기의 적응제어에 의한 속도제어 (Speed Control of Permanent Magnet Synchronous Motor by Adaptive Control)

  • 유정웅;우광준
    • 대한전기학회논문지
    • /
    • 제38권3호
    • /
    • pp.166-172
    • /
    • 1989
  • The model reference adaptive control algorithm (MRAC), which is one of the methods for controlling the speed of a permanent magnet synchronous motor (PMSM), has been developed using the autoregressive (ARMAX) method. Applying this algorithm to a microprocessor which is used in driving PMSM with PI controller, it has been proved that the response speed of the reference input follows closely that of the reference model. It has also been proved by experiments that the quick speed response without over-shoot could be obtained for the motor system with variable parameters.

  • PDF

직접 순시전압 제어기법에 의한 동기발전기의 고성능 여자 제어시스템 (A High Performance Exciter Control System of Synchronous Generator using Direct Instantaneous Voltage Control Method)

  • 이동희;양가녕;이상훈;안진우
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.68-74
    • /
    • 2007
  • 본 논문에서는 부하 변동에 강인하고, 제어기의 구성이 매우 간단한 순시전압제어기법을 적용한 여자제어 시스템을 제안한다. 제안하는 순시전압 제어기법은 제어기의 이득을 결정하기 위한 복잡한 설계가 요구되지 않으며, 제어기의 시정수 설정만으로, 전력 변환 장치의 최대 응답성을 유도 할 수 있으며 과도 응답 상태에서 오버슈트의 발생을 크게 억제할 수 있는 장점이 있다. 제안된 순시전압 제어기법에 의한 동기 발전기 여자 시스템은 컴퓨터 시뮬레이션과 소형 발전기 시스템에 적용된 실험을 통하여 그 성능을 검증하였다.

영구자석 동기전동기의 회전자 초기위치 검출 및 엘리베이터 도어의 속도제어 (Initial Rotor Position Detection a PM Synchronous Motor and Speed Control of an Elevator Door)

  • 송기영;오현철;조관열;김학원
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.556-564
    • /
    • 2013
  • This paper proposes an initial rotor position detecting algorithm of a PM synchronous motor using an incremental encoder. The proposed algorithm estimates the phase offset between the rotor magnetic flux and the Z-pulse of the incremental encoder by applying six aligning mode current control. The absolute rotor position for driving a PM synchronous motor is calculated by using the phase offset of the Z pulse and A, B pulse signals of the encoder. The PMSM drives based on the estimated rotor position is applied to the elevator door system. The door length is measured on line at first setup of the elevator. The speed control for open, close, and reopen of the elevator door is also presented and the proposed algorithm for the elevator door system is verified by experiment.

영구자석 표면부착형 동기전동기의 전류제어기를 이용한 센서리스 기동방법 및 속도제어 (Sensorless Speed Control and Starting Algorithm using Current Control of SPM Synchronous Motor)

  • 백인철;이주석;김학원
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.523-529
    • /
    • 2013
  • A sensorless speed control of a permanent magnet synchronous motor(PMSM) which utilizes MRAS based scheme to estimate rotor speed and position is presented. Considering an error between real and estimated rotor position values, a state equation of PMSM in the synchronous d-q reference frame is represented. A state equation of model system which uses estimated speed and nominal parameter values is expressed. To minimize the errors between the derivatives of d-q axis currents of real and model system, MRAS based adaptation mechanisms for the estimation of rotor speed and position are derived. On the other hand, for the acceleration stage of motor just before the sensorless operation, an acceleration scheme using only d-axis current control is proposed. To show the validity of the proposed scheme, experimental works are carried out and evaluated. During acceleration stage, the acceleration scheme using only d-axis current command shows good acceleration performance and controlled current level. For the sensorless operation, at low speed (5% of rated speed), a good performance is observed.

Neuro-Fuzzy Control of Interior Permanent Magnet Synchronous Motors: Stability Analysis and Implementation

  • Dang, Dong Quang;Vu, Nga Thi-Thuy;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1439-1450
    • /
    • 2013
  • This paper investigates a robust neuro-fuzzy control (NFC) method which can accurately follow the speed reference of an interior permanent magnet synchronous motor (IPMSM) in the existence of nonlinearities and system uncertainties. A neuro-fuzzy control term is proposed to estimate these nonlinear and uncertain factors, therefore, this difficulty is completely solved. To make the global stability analysis simple and systematic, the time derivative of the quadratic Lyapunov function is selected as the cost function to be minimized. Moreover, the design procedure of the online self-tuning algorithm is comparatively simplified to reduce a computational burden of the NFC. Next, a rotor angular acceleration is obtained through the disturbance observer. The proposed observer-based NFC strategy can achieve better control performance (i.e., less steady-state error, less sensitivity) than the feedback linearization control method even when there exist some uncertainties in the electrical and mechanical parameters. Finally, the validity of the proposed neuro-fuzzy speed controller is confirmed through simulation and experimental studies on a prototype IPMSM drive system with a TMS320F28335 DSP.

Modeling and Control of IGBT Converter-Based High-Voltage Direct Current System

  • Kim, Hong-Woo;Ko, Suk-Whan;An, Hae-Joon;Jang, Gil-Soo;Ko, Hee-Sang
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.97-104
    • /
    • 2011
  • This paper presents modeling and control for the emerging IGBT converter-based high-voltage direct-current system (IGBT-HVDC). This paper adds to the representation of the IGBT-HVDC system in the dq-synchronous reference frame and its decoupled control scheme. Additionally, since the IGBT-HVDC is able to actively support the grid due to its capacity to control independently active and reactive power production, a reactive power control scheme is presented in order to regulate/contribute to the voltage at a remote location by taking into account its operational state and limits. The ability of the control scheme is assessed and discussed by means of simulations using ahybrid power system, which consists of a permanent magnetic synchronous-generator (PMSG) based wind turbine, an IGBT-HVDC, and a local load.

망막의 3차원 영상화를 위한 데드비트 외란 관측기를 가진 고속, 고강성 제어 시스템 (High Speed and Robust Control System with Deadbeat Disturbance Observer for 3D Eye Imaging Equipment)

  • 고종선;이태훈;김영일
    • 전력전자학회논문지
    • /
    • 제8권5호
    • /
    • pp.418-426
    • /
    • 2003
  • 컴퓨터 모니터를 통해 안구망막의 형태와 두께를 보기 위해서 레이저의 경로차를 이용하는 SLO 장비가 사용되고 있다. 이러한 방법으로 망막의 선명한 3차원 영상을 보기 위해서는 레이저 광경로 시스템의 정확한 동기제어가 필요하다. 이 영상을 얼기 위해서는 평면주사를 하는데 있어서 정밀동기제어가 매우 중요하다. 본 논문에서는 안구의 3차원 영상을 만들기 위해 고속 동기제어를 구현한다. 또한 고속 제어시 부하 관성에 의해 발생하는 위치 응답의 오차를 보상하기 위해서 기존 PI(Proportional-Integral) 제어기에 데드비트 외란 관측기를 추가한다. 제안된 제어시스템은 고속 제어시 발생하는 토크 변화에 강인하고 정밀한 시스템이 된다. 이상의 제안된 시스템의 안정성과 유용함이 컴퓨터 시뮬레이션과 실험을 통하여 확인되었다.

Hybrid Sensor-less Control of Permanent Magnet Synchronous Motor in Low-speed Region

  • Yamamoto, Yasuhiro;Funato, Hirohito;Ogasawara, Satoshi
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.301-308
    • /
    • 2008
  • This paper proposes a method of improving the stability in sensor-less control of permanent magnet synchronous motors. The control method for low-speed region is divided into two: One is a high frequency method, which involves a problem of reverse rotation once misdetection of the permanent magnet polarity should occur, and another one is a current drive method, which has a problem that phase and speed oscillations are caused by quick speed changes. Hence, authors propose adoption of the current drive method for the basic control system with added compensation of stabilization by means of the high frequency method. This combination secures stable control with no risk of reversal and less vibration. In addition, authors have also considered a frequency separation filter of a shorter delay time so that current control performance will not lower even when high frequencies are introduced. This filter has achieved simplified compensation using repetitive characteristic through the utilization of the periodicity of high frequency current. Simulation and experiment have been conducted to verify that the stable performance of this system is improved.

Low Parameter Sensitivity Deadbeat Direct Torque Control for Surface Mounted Permanent Magnet Synchronous Motors

  • Zhang, Xiao-Guang;Wang, Ke-Qin;Hou, Ben-Shuai
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1211-1222
    • /
    • 2017
  • In order to decrease the parameter sensitivity of deadbeat direct torque control (DB-DTC), an improved deadbeat direct torque control method for surface mounted permanent-magnet synchronous motor (SPMSM) drives is proposed. First, the track errors of the stator flux and torque that are caused by model parameter mismatch are analyzed. Then a sliding mode observer is designed, which is able to predict the d-q axis currents of the next control period for one-step delay compensation, and to simultaneously estimate the model parameter disturbance. The estimated disturbance of this observer is used to estimate the stator resistance offline. Then the estimated resistance is required to update the designed sliding-mode observer, which can be used to estimate the inductance and permanent-magnetic flux linkage online. In addition, the flux and torque estimation of the next control period, which is unaffected by the model parameter disturbance, is achieved by using predictive d-q axis currents and estimated parameters. Hence, a low parameter sensitivity DB-DTC method is developed. Simulation and experimental results show the validity of the proposed direct control method.

LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석 (Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter)

  • 조종민;이태진;윤동현;차한주
    • 전력전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.