• Title/Summary/Keyword: Synchronous Control

Search Result 1,730, Processing Time 0.025 seconds

Application of Self Tuning Fuzzy Controller for System Stability Improvement (시스템 안정도 개선을 위한 자기조정 퍼지제어기 적용)

  • Hur, Dong-Ryol;Joo, Seok-Min;Kim, Hai-Jai
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents a control approach for designing a self tuning fuzzy controller for SVC system, A SVC constructed by a Fixed Capacitor and a Thyristor Controlled Reactor is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage, The proposed parameter self tuning algorithm of fuzzy controller is based on the steepest decent method using two direction vectors which make error between inference values of fuzzy controller and output values of the specially selected PSS reduce steepestly, The related simulation results show that the proposed fuzzy controller is more powerful than the conventional ones.

  • PDF

Maximum Efficiency Point Tracking Control of Permanent Magnet Synchronous Motors (영구자석 동기전동기의 최대 효율점 추적 제어)

  • Lee, Kwang-Woon;Kim, Seong-Hwan;Yoo, Ji-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.331-333
    • /
    • 2007
  • 전동기의 동손 및 철손을 포함한 손실이 최소가 되는 운전 점을 추적함으로써, 전동기의 제정수 변동에 무관하게 항상 최대 효율점에서 영구자석 동기전동기를 운전할 수 있는 새로운 최대 효율 제어 알고리즘을 제안한다. 제안된 최대 효율점 추적 제어 알고리즘은 전류의 위상각 변동에 따른 가변속 구동장치의 입력 전력 변화로부터 부하 변동에 의한 영향을 제거함으로써 정상 상태에서 부하변동에 무관하게 최대 효율점으로 수렴이 가능하고, 그 구성이 단순하기 때문에 산업계에 널리 적용될 수 있다. 실험을 통해 제안된 알고리즘의 효용성을 입증한다.

  • PDF

PMSM Voltage Control of Electric Vehicles for High Energy Recovery (높은 에너지 회수를 위한 전기자동차용 PMSM 전압제어)

  • Jung, sung-chul;Lee, ik-sun;Ko, jong-sun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.152-155
    • /
    • 2017
  • 본 논문에서는 에너지 회수를 최대화하기 위하여 전기자동차의 PMSM(Permanent Magnet Synchronous Machine)으로부터 발생된 전압을 제어하는 방법을 다룰 것이다. 이 방법은 PMSM의 제동에너지를 전기에너지로 회생하기 위해 L-C 공진회로를 구성하고 배터리에 많이 충전할 수 있도록 전압을 제어한다. 일반적인 전기자동차의 경우 회생된 큰 전압이 배터리에 들어가 망가지는 현상을 방지하기 위해 스위칭 소자를 사용하여 회로를 끊어주어서 그 큰 전압을 사용하지 못한다. 이러한 회생된 큰 전압으로 제어하여 사용함으로써, 에너지 회수율이 증가하고 전기자동차의 주행거리가 증가할 수 있다. L-C 공진회로에서 FET 게이트에 전압을 인가하는 제어기의 구동 펄스에 따른 전압 변화를 분석하였다. 전압은 듀티에 따라 변해 PI 제어기를 통한 듀티 제어를 하는 전압제어 알고리즘을 연구하였다. 그리고 이를 Matlab Simulink를 이용하여 모의실험을 통해 검증하였다.

  • PDF

Sensorless Control Algorithm of a PM Synchronous Motor Under Naturally Rotating by Load (외부부하에 의해 회전중인 영구자석동기전동기의 센서리스 제어 알고리즘)

  • Lee, Han Sol;Cho, Kwan Yuhl;Kim, Hag Wone;Cha, Youn Cheul
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.72-73
    • /
    • 2017
  • 자동차 라디에이터용 팬과 에어컨 실외기 팬의 경우 영구자석동기 전동기는 자연 상태에서 외부 바람에 의해 임의의 방향과 임의의 속도로 회전할 수 있다. 이런 응용분야에서 회전자 위치검출 센서가 부착되어 있는 경우에는 회전방향 및 속도를 비교적 간단하게 제어할 수 있다. 그러나 회전자 위치검출 센서를 사용하지 않는 센서리스 제어의 경우 외부부하에 의해 회전자가 회전중일 때는 회전자의 위치정보가 없기 때문에 추가적인 알고리즘이 필요하다. 본 논문에서는 외부부하에 의해 회전자가 임의의 방향 및 임의의 속도로 회전하고 있는 경우 원하는 회전방향으로 원하는 속도로 제어하기 위한 센서리스 제어 알고리즘을 제안한다. 회전자가 역방향 및 정방향 저속으로 회전중인 경우와 정방향 고속으로 회전중인 경우에 대해 회전자를 정방향의 주어진 속도로 제어하기 위한 회전자 위치검출 및 센서리스 제어 알고리즘을 제안하고 실험으로 검증한다.

  • PDF

Improved Control Method for Seamless Mode Transfer of Grid Connected Single-Phase Inverter in Synchronous Rotating Frame (계통 연계 단상 인버터의 양방향 모드 전환을 위한 동기 회전 좌표계에서의 개선된 제어 기법)

  • Lee, Kang-Joo;Kim, Bum-Jun;Kum, Ho-Jung;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.329-330
    • /
    • 2017
  • 본 논문에서는 계통 연계 단상 인버터의 양방향 모드 전환을 위한 새로운 제어 기법을 제안하였다. 일반적으로 DC 측과 AC 측 사이의 전력 흐름은 d-q 동기 회전 좌표계에서 계통 연계 인버터의 전류 지령치에 의해 제어된다. 따라서 전력 흐름의 방향이 변경되면 전류 지령치를 반전하는 것이 일반적이다. 그러나 전류의 급격한 변화를 초래하고 과도상태가 길어지는 등 AC 측의 전력 품질을 악화시킨다. 따라서 본 논문에서는 동기 회전 좌표계에서의 원활한 모드 전환을 위한 향상된 제어 기법을 제안한다. 이론적 분석과 시뮬레이션 결과로 제안된 제어 기법의 타당성을 입증한다.

  • PDF

Optimum design of slotless PMLSM by using multiobjective function neural network (다중목적함수 신경 회로망을 이용한 slotless PMLSM의 최적 설계)

  • Kim, Mi-Yong;Lee, Dong-Yeup;Jung, Chun-Gil;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.855-857
    • /
    • 2003
  • A slotless Permanent Magnet Linear Synchronous Motor (PMLSM) has good control ability but thrust density is low. So, this paper proposes inserted core type of slotless PMLSM to improve its low thrust density. Inserting the core between windings of each phase, detent force is generated by the difference of magnetic resistance in an air gap. To minimize detent force and maxize thrust, this paper applies the neural network to inserted core type of slotless PMLSM.

  • PDF

Three Dimensional Networked Virtual Reailty Architecture Enabling Flexible Configuration Based on Function Distribution

  • Yasuyuki-KIYOSUE;Shohei-SUGAWARA;Shigeki-MASAKI;Susumu-ICHINOSE
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.23.1-28
    • /
    • 1999
  • InterSpaceTM is an advanced networked virtual reality system that presents shared three-dimensional computer graphics (CG) worlds via the Internet where multiple users can enjoy synchronous communications with voice, video and text. Users can control their avatars as a surrogate interface. In InterSpace users can walk around and interact with other people and interact with contents. In this paper, we describe the function-distributed architecture used in InterSpace. The architecture enables flexible configuration of server functions and load distribution. It also allows users to select media and client PCs to switch servers dynamically.

A Study on Over Current Protection Method of Unified Power Quality Conditioners (통합 전력품질 제어기의 과전류 보호방법에 관한 연구)

  • Chae Beom-Seok;Lee Woo-Cheol;Lee Taeck-Ki;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF

A Study of Torque Ripple Minimization and Maximum Torque Control for IPMSM with Non Sinusoidal Back-EMF (비정현적인 역기전력을 가진 IPMSM의 토크리플 저감과 최대토크 제어에 관한 연구)

  • Hong In-Pyo;Lee Sang-Hun;Choi Cheol;Kim Jang-Mok;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.142-145
    • /
    • 2001
  • In this paper the electromagnetic torque developed in IPMSM(Interior Permanent Magnet Synchronous Motor) is analyzed. If flux distributions in the motor are not sinusoidal, a sinusoidal current produces important torque ripple. Torque ripple causes vibration and noise of motors. The optimized current waveforms for ripple free is able to be obtained by analysis of Back-EMF and torque equation. The method to find the optimal current is based on numerical predetermination. In this paper proposes current waveform which can eliminate the torque ripple, and the validity is verified through the simulation.

  • PDF

Development of the Triple Modular Redundant Excitation System with Simulator for 500MW Synchronous Generator (500MW 동기발전기용 시뮬레이터 탑재형 디지털 삼중화 여자시스템 개발)

  • Ryu, Hoseon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.70-75
    • /
    • 2014
  • TMR(triple modular redundant) digital excitation system with simulator is developed for tuning optimal control parameters during commissioning test and coping with system faults rapidly. A new system which mocks up virtual generator, turbine, grid can simulate as if excitation system is connected to a real generator system by setting four switches. The maintenance crew using the simulator is able to test perfectly the phase controller rectifiers, field breaker, sequence relays as well as TMR controller of the excitation system. Commissioning and performance results about the excitation system with simulator is discussed. The trial product was installed and operated at a 500MW thermal power plant after the commissioning test.