• Title/Summary/Keyword: Symmetrical

Search Result 1,256, Processing Time 0.034 seconds

The Coupling Characteristics of Symmetrical Dielectric Waveguide Coupler (대칭유전체 도파로의 결합특성)

  • 박동명;김윤명;진년강
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.20-22
    • /
    • 1986
  • This paper represents a graphical design technique of the symmetrical dielectric waveguids couplers. Once the phase constants are given by a approzimate model analysis, coupling lengths are easily calculated for each coupler. These method give some new insight of the codirectional couplers.

  • PDF

The Synaptic Organization of the Cat Striatum (고양이 선조체의 신경연접기구에 대한 형태학적 관찰)

  • Chung Jin-Woong;Choi Wol-Bong;Kwun Hung-Sik
    • Applied Microscopy
    • /
    • v.8 no.1
    • /
    • pp.53-66
    • /
    • 1978
  • An attempt has been made to discriminate the synapses in the striatum consisting caudate nucleus, putamen and fundus striati of the cat with emphasis on the characteristic structures of axon terminals and postsynaptic profiles. The differentiation is based on the size and shape of vesicle in the bouton terminal, and the symmetrical or asymmetrical thickening the pre- and postsynaptic membrane. Four types of synapses could be differentiated: Type I: the bontons with asymmetrical,synaptic thickenings contain round 45 nm diameter vesicles and contact cell soma, dendritic shafts and dendritic spines (74%). Type II : the boutons contain round 45nm diameter vesicles and are associated with symmetrical membrane thickenings. These synapses are formed on the soma and dendritic shafts (6%). Type III: the boutons with symmetrical membrane thickenings contain 50-60 nm diameter pleomorphic vesicles, and contact soma and dendritic shafts (18%). Type IV: the terminals contain flattened vesicles ($25{\times}45 nm$) and are associated with symmetrical membrane thickenings. These synapses are found in contact with soma and dendritic shafts. Additionally, the bouton en passant, which is expanded from myelinated or unmyelinated axons containing round vesicles (45nm diameter) contacts the dendritic shaft or dendritic spine with asymmetrical membrane thickenings. Two unusual types of synapses, axo-axonic and dendro-dendritic, are found occasionally.

  • PDF

Brain Activation During the Wrist Movement Using Symmetrical Upper Limb Motion Trainer (대칭형 상지 운동기구를 이용한 손목 운동 시 뇌 활성도 패턴)

  • 태기식;김사엽;송성재;이소영;박기영;손철호;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1303-1306
    • /
    • 2004
  • We developed a symmetrical upper limb motion trainer for chronic hemiparetic subjects. This trainer enabled the practice of a forearm pronatio $n^ination and wrist flexion/extension. In this study, we have used functional magnetic resonance imaging(fMRI) with the developed symmetrical upper limb motion device, to compare brain activation patterns elicited by flexion/extension wrist movements of control and hemiparetic subject group. In control group, contralateral somatosensory cortex(SMC) and bilateral cerebellum were activated by dominant hand movement(Task 1), while bilateral movements by dominant hand(Task 2) activated the SMC in both cerebral hemispheres and ipsilateral cerebellum. However, in hemiparetic subject group, contralateral supplymentary motor area(SMA) was activated by unaffected hand movement(Task 1), while the activation of bilateral movements by unaffected hand(Task 2) showed only SMA in the undamaged hemisphere. This study, demonstrating the ability to accurately measure activation in both sensory and motor cortex, is currently being extended to patients in clinical applications such as the recovery of motor function after stroke.ke.

  • PDF

Training Effect of Symmetrical Standing Posture in Hemiplegic Patients Using Auditory and Visual Biofeedback (시각 및 청각 되먹임을 통한 편마비 환자의 좌우대칭적 서기자세 훈련효과)

  • Kim, Hyong-Back;Lee, Soo-Chul;Choo, Do-Youn;Choi, Kyu-Hwan
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.42-48
    • /
    • 1996
  • Weight bearing training on the involved leg is impotant for ambulation and activities of daily living in ambulatory hemiplegic patients. Traditionally, physical therapists have relied on exercise therapy and subjective evaluation. The goal for this study was to measure lower extremity weight distribution in standing with ten hemiplegic pations(M:8, F:2) and to determine the traing effect on symmetrical standing posture using a "Limloader". The Limloader is a machine designed for training symmetrical weight bearing posture. The results showed that the ability to keep the center of gravity within the limits for balance was improved significantly but the ability to adjust weight bearing on the involved leg was not (p<0.05). This study demostrated that hemiplegics can improved their symmetrical weight bearing ability using sensory biofeedback.

  • PDF

A New fault Location Algorithm for a Line to Ground fault Using Direct 3-phase Circuit Analysis in Distribution Power Networks (3상회로 직접해석에 의한 배편계통 1선지락사고 고장거리 계산 알고리즘)

  • Choe, Myeon-Song;Lee, Seung-Jae;Lee, Deok-Su;Jin, Bo-Geon;Min, Byeong-Un
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.409-416
    • /
    • 2002
  • This paper presents a fault location algorithm using direct 3-phase circuit analysis for distribution power networks. The unbalanced feature of distribution networks due to single phase loads or asymmetric operation prohibits us from using the conventional symmetrical component transformation. Even though the symmetrical component transformation provides us with a very easy tool in three phase network analysis, it is limited to balanced systems in utilizing its strong point, which is not suitable for distribution networks. In this paper, a fault location algorithm using direct 3-phase circuit analysis is developed. The algorithm is derived and it Is shown that the proposed method if we use matrix inverse lemma, is not more difficult then the conventional methods using symmetrical component transformation. Since the symmetrical component transformation is not used in the suggested method, unbalanced networks also can be handled with the same difficulty as balanced networks. The case study results show the correctness and effectiveness of the proposed algorithm.

A New Distribution System Power Flow Method Using Symmetrical Components (대칭성분을 이용한 3상 배전계통 조류계산 기법)

  • Choe, Jeong-Hwan;Jeong, Seong-Il;Park, Je-Yeong;Kim, Gwang-Ho;Kim, Jae-Eon;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • This paper proposes a new power flow method for distribution system analysis by modifying the conventional back/forward sweep method using symmetrical components. Since the proposed method backward and forward sweeps with the variables expressed by symmetrical components, this method reduces computation time for matrix calculations; therefore, it is able to reduce the computational burden for real-time distribution network analysis. The proposed method was also developed to effectively analyze the unbalanced distribution system installing AVR(Auto Voltage Regulator), shunt capacitors. The proposed algorithm was compared with the conventional Back/forward Sweep method by applying both methods to three phase unbalanced distribution system of IEEE 123-bus model, and the test results showed that the proposed method would outperformed the conventional method in real-time distribution system analysis.

Analysis and Design of a DC-Side Symmetrical Class-D ZCS Rectifier for the PFC of Lighting Applications

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon;Higuchi, Kohji
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.621-633
    • /
    • 2015
  • This paper proposes the analysis and design of a DC-side symmetrical zero-current-switching (ZCS) Class-D current-source driven resonant rectifier to improve the low power-factor and high line current harmonic distortion of lighting applications. An analysis of the junction capacitance effect of Class-D ZCS rectifier diodes, which has a significant impact on line current harmonic distortion, is discussed in this paper. The design procedure is based on the principle of the symmetrical Class-D ZCS rectifier, which ensures more accurate results and provides a more systematic and feasible analysis methodology. Improvement in the power quality is achieved by using the output characteristics of the DC-side Class-D ZCS rectifier, which is inserted between the front-end bridge-rectifier and the bulk-filter capacitor. By using this symmetrical topology, the conduction angle of the bridge-rectifier diode current is increased and the low line harmonic distortion and power-factor near unity were naturally achieved. The peak and ripple values of the line current are also reduced, which allows for a reduced filter-inductor volume of the electromagnetic interference (EMI) filter. In addition, low-cost standard-recovery diodes can be employed as a bridge-rectifier. The validity of the theoretical analysis is confirmed by simulation and experimental results.

N-gram Feature Selection for Text Classification Based on Symmetrical Conditional Probability and TF-IDF (대칭 조건부 확률과 TF-IDF 기반 텍스트 분류를 위한 N-gram 특질 선택)

  • Choi, Woo-Sik;Kim, Seoung Bum
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.4
    • /
    • pp.381-388
    • /
    • 2015
  • The rapid growth of the World Wide Web and online information services has generated and made accessible a huge number of text documents. To analyze texts, selecting important keywords is an essential step. In this paper, we propose a feature selection method that combines a term frequency-inverse document frequency technique and symmetrical conditional probability. The proposed method can identify features with N-gram, the sequential multiword. The effectiveness of the proposed method is demonstrated through a real text data from the machine learning repository, University of California, Irvine.

The Optimization Method of Symmetrical Building Plan Using Point Group Theory (포인트그룹 이론을 이용한 대칭적 건물 평면형태의 최적대안 결정방안)

  • 진경일
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.75-82
    • /
    • 2003
  • The symmetry is general geometric design principal in contemporary architecture shape. But, Symmetry sometimes easily causes unreasonable design. In some reason, two of symmetric units in the apartment, one side of unit have very reasonable plan and arrangement but opposite side unit nay not. For example, if the kitchen on right unit had right-handed arrangement, the symmetrical other would have left-handed kitchen arrangement. In addition to this, if each house unit has the same plan but different direction, each unit has different usage or affects the residents' life pattern. Nevertheless, Architects use only one unit plan to design public housing development by using symmetric operator (mirror, proper rotation, inversion center) at their option. This study suggests that using group theory and mathematical matrix rather than designer's discretion can solve this symmetry problem clearly. And, this study analysis the merits and demerits between each symmetrical pair of unit plan shapes by using mathematical point group theory and matrix.

Development of 3 phase Power Flow calculation algorithm in distribution Power Systems using Symmetrical Component (Symmetrical Components를 이용한 배전계통 3상 조류 계산 알고리즘 개발)

  • Choi, J.H.;Jang, S.I.;Kim, K.H.;Park, J.K.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.147-149
    • /
    • 2000
  • This paper describes a power flow method for distribution systems, applying the method of symmetrical component to back/forward sweep method. The proposed algorithm is effective for unbalanced radial distribution system, with process of distributed resource(PQ & PV node), AVR(Auto Voltage Regulator), shunt capacitor. This proposed method compared conventional back/forward sweep method with the using three phase unbalanced distribution systems with 34 nodes.

  • PDF