• 제목/요약/키워드: Symmetrical

검색결과 1,256건 처리시간 0.023초

고양이 담창구 (Globus Pallidus)의 신경원과 연접기구에 대한 미세구조 (Fine Structure of Neurons and Synaptic Organization in Pallidum of the Cat)

  • Park, W.B.;C.Y. Yun
    • 한국동물학회지
    • /
    • 제26권2호
    • /
    • pp.107-123
    • /
    • 1983
  • The globus pallidus of normal cats were prepared for electron microscopic study following perfusion with a mixture of 1% paraformaldehyde and 1% glutaraldehyde solution. Neurons of two size categories were identified in 1 $\\mu$m araldite sections and their ultrastructural characteristics were studied in adjacent thin section. 1. Large neurons ($30 \\mum \\times 45 \\mum$ in diameter) had extensive areas of rough surfaced endoplasmic reticulm, abundant perinuclear Golgi complex, numerous mitochondria and lipofusin granule, and had a large spherical nucleus with shallow indentation of nuclear manbrane. Small neurons ($17 \\mum \\times 27 \\mum$ in diameter) had poorly rough surfaced endoplasmic reticulum, moderate number of mitochondria and randomly distributed Golgi complex. The nuclear envelope of this cell frequently showed multiple deep invagination. 2. Three types of axo-somatic synapses were identified on the basis of the size and shape of vesicle in the axon terminal and the symmetrical or asymmetrical thickening at the synaptic site. Type I synaptic terminal shows an even distribution of round and oval synaptic vesicles, and has a symmetrical synaptic thickening. Type II axon terminals reveal mostly round and pleomorphic vesicles and a few vesicles were localized near the presynaptic membrane in pale axoplasm and its synaptic thickening were symmetric. Type III axon terminals contain round vesicles, which were aggregated in the axoplasm, and has a asymmetrical synaptic thickening. 3. The majority of axo-somatic contact with the large and small neurons were type I, and type II and III synapes were rare.

  • PDF

역정규 손실함수를 이용한 다변량 공정능력지수 (Multivariate Process Capability Index Using Inverted Normal Loss Function)

  • 문혜진;정영배
    • 산업경영시스템학회지
    • /
    • 제41권2호
    • /
    • pp.174-183
    • /
    • 2018
  • In the industrial fields, the process capability index has been using to evaluate the variation of quality in the process. The traditional process capability indices such as $C_p$, $C_{pk}$, $C_{pm}$ and $C^+_{pm}$ have been applied in the industrial fields. These traditional process capability indices are mainly applied in the univariate analysis. However, the main streams in the recent industry are the multivariate manufacturing process and the multiple quality characteristics are corrected each other. Therefore, the multivariate statistical method should be used in the process capability analysis. The multivariate process indices need to be enhanced with more useful information and extensive application in the recent industrial fields. Hence, the purpose of the study is to develop a more effective multivariate process index ($MC_{pI}$) using the multivariate inverted normal loss function. The multivariate inverted normal loss function has the flexibility for the any type of the symmetrical and asymmetrical loss functions as well as the economic information. Especially, the proposed modeling method for the multivariate inverted normal loss function (MINLF) and the expected loss from MINLF in this paper can be applied to the any type of the symmetrical and asymmetrical loss functions. And this modeling method can be easily expanded from a bivariate case to a multivariate case.

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Estimation of main cable tension force of suspension bridges based on ambient vibration frequency measurements

  • Wang, Jun;Liu, Weiqing;Wang, Lu;Han, Xiaojian
    • Structural Engineering and Mechanics
    • /
    • 제56권6호
    • /
    • pp.939-957
    • /
    • 2015
  • In this paper, a new approach based on the continuum model is proposed to estimate the main cable tension force of suspension bridges from measured natural frequencies. This approach considered the vertical vibration of a main cable hinged at both towers and supported by an elastic girder and hangers along its entire length. The equation reflected the relationship between vibration frequency and horizontal tension force of a main cable was derived. To avoid to generate the additional cable tension force by sag-extensibility, the analytical solution of characteristic equation for anti-symmetrical vibration mode of the main cable was calculated. Then, the estimation of main cable tension force was carried out by anti-symmetric characteristic frequency vector. The errors of estimation due to characteristic frequency deviations were investigated through numerical analysis of the main cable of Taizhou Bridge. A field experiment was conducted to verify the proposed approach. Through measuring and analyzing the responses of a main cable of Taizhou Bridge under ambient excitation, the horizontal tension force of the main cable was identified from the first three odd frequencies. It is shown that the estimated results agree well with the designed values. The proposed approach can be used to conduct the long-term health monitoring of suspension bridges.

Assessment of non-prismatic beams having symmetrical parabolic haunches with constant haunch length ratio of 0.5

  • Yuksel, S. Bahadir
    • Structural Engineering and Mechanics
    • /
    • 제42권6호
    • /
    • pp.849-866
    • /
    • 2012
  • Single span historic bridges often contain non-prismatic members identified with a varying depth along their span lengths. Commonly, the symmetric parabolic height variations having the constant haunch length ratio of 0.5 have been selected to lower the stresses at the high bending moment points and to maintain the deflections within the acceptable limits. Due to their non-prismatic geometrical configuration, their assessment, particularly the computation of fixed-end horizontal forces (FEFs) and fixed-end moments (FEMs) becomes a complex problem. Therefore, this study aimed to investigate the behavior of non-prismatic beams with symmetrical parabolic haunches (NBSPH) having the constant haunch length ratio of 0.5 using finite element analyses (FEA). FEFs and FEMs due to vertical loadings as well as the stiffness coefficients and the carry-over factors were computed through a comprehensive parametric study using FEA. It was demonstrated that the conventional methods using frame elements can lead to significant errors, and the deviations can reach to unacceptable levels for these types of structures. Despite the robustness of FEA, the generation of FEFs and FEMs using the nodal outputs of the detailed finite element mesh still remains an intricate task. Therefore, this study advances to propose effective formulas and dimensionless estimation coefficients to predict the FEFs, FEMs, stiffness coefficients and carry-over factors with reasonable accuracy for the analysis and re-evaluation of the NBSPH. Using the proposed approach, the fixed-end reactions due to vertical loads, and also the stiffness coefficients and the carry-over factors of the NBSPH can be determined without necessitating the detailed FEA.

합성 괴타이트에 대한 압축실험 (Compression Study on a Synthetic Goethite)

  • 김영호;황길찬;김순오
    • 한국광물학회지
    • /
    • 제22권4호
    • /
    • pp.325-330
    • /
    • 2009
  • 합성 FeOOH-괴타이트 분말시료에 대한 고압실험을 압축성을 검증하기 위해 상온에서 시행하였다. 방사광이용 실험장치에서 대칭다이아몬드 앤빌기기를 각분산회절방법으로 배열하여 실험을 하였다. $K_{T'}$ 값을 4.0으로 가정하였을 때, 체적탄성률은 222.8 GPa로 계산되었다. 이 값은 천연산 괴타이트로부터 얻은 기존의 값과 비교하여 볼 때 매우 높은 값으로, 시료의 생성조건에 따라 나타나는 물질의 압력에 대한 이상 거동에 대해 고찰하였다.

Distortion Compensation of WDM Signals with initial frequency chirp in the Modified Mid-Span Spectral Inversion Technique

  • Lee, Seong-Real
    • Journal of information and communication convergence engineering
    • /
    • 제5권1호
    • /
    • pp.17-22
    • /
    • 2007
  • In this paper, the optimal value of optical phase conjugator (OPC) position and the optimal values of dispersion coefficients of fiber sections for the best compensation of the distorted WDM signals with frequency chirp of -1 are induced to alternate with the symmetrical distributions of power and local dispersion with respect to OPC, which is difficult to form in real optical link due to fiber attenuation in mid-span spectral inversion (MSSI) technique. It is confirmed that the Q-factors of total channels of -18.5 dBm launching light power exceed 16.9 dB, which value corresponds to 10-12 BER, by applying the induced optimal parameter values into 16 channels ${\times}$ 40 Gbps WDM system, on the other hand the Q-factors of only 9 channels exceed that value in WDM system with the conventional MSSI technique. Thus, it is expected to expand the availability of OPC in WDM system through the using of the optimal parameter values that are induced by the proposed method in this paper, without the symmetrical distributions of power and local dispersion.

2상 유도전동기의 구동을 위한 2상 인버터의 2상 공간전압벡터 PWM 방식 (Space Vector PWM Technique for Two-Phase Inverter-Fed Two-Phase Induction Motors)

  • 장도현;윤덕용
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 본 논문에서는 2상 인버터용 공간전압벡터 PW 방식을 제안하였다. 제안된 2상 공간전압벡터 PWM 방식은 2상 유도전동기에 적용할 수 있다. 2상 공간전압벡터 방식을 사용하는 2상 인버터는 4개의 공간 전압벡터를 발생하나 영 전압 벡터는 만들 수 없다. 2상 인버터에서는 4개의 공간 전압벡터를 조정하여 기본 전압벡터를 실현한다. 또한, 2상 공간전압벡터방식에 의해 최적의 PWM 전압파형을 만들기 위한 대칭변조방식이 제안되었다. 제안된 2상 공간 전압벡터방식에 대한 타당성을 확인하기 위해 시뮬레이션과 실험이 실행되었다.

1선지락사고에 대한 초전도한류기의 동작특성 (Operating properties of resistive type superconducting fault current limiters with a single line-to-ground fault)

  • Park, Hyo-Sang;Park, Chang-Joo;Lee, Sang-il;Chung, Soo-Bok;Oh, Geum-Kon;Chung, Hun-Sang
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.279-281
    • /
    • 2003
  • We analysed the operating properties of resistive type superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased up to about 6 times of transport currents immediately after the fault instant and was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unsymmetrical rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unsymmetrical rates of currents were noticeably improved within one cycle after the fault instant. We calculated the zero phase currents for a single line-to-ground fault using the symmetrical component analysis. The positive sequence resistance was reduced remarkably right after the fault but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase symmetrical state in about 60 ㎳ after the fault. The ground currents were almost 3 times of the zero phase mts since most of the fault currents flowed through the grounding line.

  • PDF

음이온 생성을 위한 표면 유전체장벽방전의 설계조건 연구 (A Study of The Surface Dielectric Barrier Discharge Design Conditions for Generating Negative Air Ions)

  • 신상문;김정윤;김종수;최재하;최원호
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.114-122
    • /
    • 2014
  • This paper describes a study of the design conditions of a planar surface dielectric barrier discharge (DBD) reactors for generating negative air ions. The capacity of negative air ion generated by the surface DBD reactor is affected by the shape, area ratio and the location of the discharge and induction electrodes of it. To study the optimal design conditions of DBD reactors, the electrodes printed on the substrate of a PCB board is utilized to conduct kind of experiments: the distance of the each electrode along with the X-Y axis, the area ratio of the discharge electrode to induction electrode, and the symmetrical and asymmetrical location of two electrodes. The ion generation capacity is inverse proportional to the gap increases along with X-Y axis. And the optimum ion concentration generated by the ionizer was inspected when the electrodes area ratio was 3 and 5 times of the symmetrical and asymmetrical experimental condition respectively.