• 제목/요약/키워드: Switching tables

검색결과 15건 처리시간 0.018초

Comparison of Efficiency for Different Switching Tables in Six-Phase Induction Motor DTC Drive

  • Taheri, Asghar;Rahmati, Abdolreza;Kaboli, Shahriyar
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, different switching tables proposed for the Direct Torque Controlled (DTC) of a six-phase induction machine are simulated and implemented. A six-phase induction motor has 64 space voltage vectors which result in increased complexity in the selecting of inverters switching. The unsuitable selection of a switching table leads to large harmonics especially at low speed and it also reduces drive efficiency. A six-phase induction machine has large zero sequence harmonic currents of the order $6{\kappa}{\pm}1$. These harmonic currents are varied in various techniques. Decreasing this loss is essential in a six-phase induction machine. The main purpose of this paper is to improve the ST-DTC of six-phase induction machines to reduce the voltage and current harmonics and the torque pulsation. Selecting a suitable method for minimizing these harmonics is very important.

계량조정형(計量調整型) 샘플링 검사(檢査)에 관(關)한 연구(硏究) (Variables Sampling Inspection Procedures and Tables with Severity Adjustment)

  • 배도선;홍성훈;손미애
    • 대한산업공학회지
    • /
    • 제16권1호
    • /
    • pp.1-15
    • /
    • 1990
  • An AQL type variables sampling system with switching rules is proposed. Comparative studies of existing variables sampling standards - MIL-STD-414, ANSI Z1.9, ISO 3951, and BS 6002 - are made, and simulation studies on switching procedures are conducted. Based on comparative and simulation studies, a variables sampling standard for Korean industry is proposed. The master sampling tables of the proposed standard are taken from the variables standard ANSI Z 1. 9 and the switching rules are matched to the attributes standard KS A 3109 to enable us to move between the proposed variables standard and KS A 3109. Composite OC and ASN curves of the proposed standard are calculated for selected combinations of lot sizes and AQL's and they are compared with those of ANSI Z1.9.

  • PDF

Problems of Stator Flux Estimation in DTC of PMSM Drives

  • Kadjoudj, M.;Golea, N.;Benbouzid, M.E.H
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.468-477
    • /
    • 2007
  • The DTC of voltage source inverter-fed PMSMs is based on hysteresis controllers of torque and flux. It has several advantages, namely, elimination of the mandatory rotor position sensor, less computation time, and rapid torque response. In addition, the stator resistance is the only parameter, which should be known, and no reference frame transformation is required. The DTC theory has achieved great success in the control of induction motors. However, for the control of PMSM drives proposed a few years ago, there are many basic theoretical problems that must be clarified. This paper describes an investigation into the effect of the zero voltage space vectors in the DTC system and points out that if using it rationally, not only can the DTC of the PMSM drive be driven successfully, but torque and flux ripples are reduced and overall performance of the system is improved. The implementation of DTC in PMSM drives is described and the switching tables specific for an interior PMSM are derived. The conventional eight voltage-vector switching table, which is namely used in the DTC of induction motors does not seem to regulate the torque and stator flux in a PMSM well when the motor operates at low speed. Modelling and simulation studies have both revealed that a six voltage-vector switching table is more appropriate for PMSM drives at low speed. In addition, the sources of difficulties, namely, the error in the detection of the initial rotor position, the variation of stator resistance, and the offsets in measurements are analysed and discussed.

광 버스트 스위칭 네트워크에서 Look-Ahead 알고리즘을 적용한 그룰 스케줄링의 성능 분석 (Performance Analysis of Group Scheduling with Look-Ahead Algorithm for Optical Burst Switching Networks)

  • 신종덕;장원석
    • 한국통신학회논문지
    • /
    • 제31권12B호
    • /
    • pp.1037-1043
    • /
    • 2006
  • 본 논문에서는 광 버스트 스위칭 네트워크의 코어 노드에 그룹 스케줄링을 적용한 경우 발생하는 데이터 버스트 처리 지연시간의 감소를 위한 알고리즘을 제안하였다. 이 알고리즘에서는 일차 스케줄링 세션 종료 직후에, 스케줄링 창 내의 모든 빈 공간(void) 정보를 나타내는 표를 생성하기 때문에, 직전 스케줄링에서 예약에 실패한 데이터 버스트들을 다른 채널의 빈 공간에 재할당할 때, 이 표를 활용하여 효과적으로 버스트 처리 시간 지연을 감소시킬 수가 있다. 이 알고리즘이 적용된 그룹 스케줄링 방식과 기존의 그룹 스케줄링 방식을 비교한 결과, 채널 이용률에 있어서는 서로 거의 동일한 성능을 보이나, 버스트 손실 확률과 파장 변환률은 알고리즘을 적용한 그룹 스케줄링 방식이 기존의 그룹 스케줄링 방식보다 약간 우수하였다. 버스트 처리 시간에 있어서는 부하가 약 0.6이하인 영역에서는 기존 그룹 스케줄링 방식이 약간 빠른 반면에, 부하가 0.8이상인 영역에서는 알고리즘을 적용한 방식의 처리 시간이 현저히 짧게 나타났다, 부하 0.9에서 약 1/2.1로 감소하였다.

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

UMTS 망에서의 SG 도입을 통한 신호망 구조 연구 (A Study of Signaling Network Architecture in UMTS Networks Using Signaling Gateway)

  • 조정제;박상훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.187-188
    • /
    • 2006
  • In CDMA based mobile communication network, signaling messages are routed through Signaling Transfer Point(STP) which is responsible for MTP layer 3 switching. As WCDMA based UMTS network is considered as next generation technology allowing global roaming services, all nodes in networks have their own identity number called Global Title(GT). Therefore, it is essential to introduce Signaling Gateway(SG) responsible for SCCP layer switching to solve the problem each node has all GT tables including even all overseas nodes. In this paper, we propose the signaling network architecture in UMTS networks using SG and we show that we can reduce CAPEX and OPEX in each node. To show the validity of the proposed method some simulations are given in which the results can be expected by intuitive observation.

  • PDF

병렬 컴퓨터를 위한 저지연 프로그램형 조견표 경로지정 엔진 (Low-Latency Programmable Look-Up Table Routing Engine for Parallel Computers)

  • 장래혁
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제6권2호
    • /
    • pp.244-253
    • /
    • 2000
  • 병렬 컴퓨터의 메시지 전달에서 응용에 관계없이 일반적으로 우수한 경로 지정 및 스위칭 정책은 존재하지 않으므로, 사용자가 응용에 따라서 정책을 변경할 수 있게 하는 것이 바람직하다. 본 논문에서는 마이크로프로세서 구조에 기초한 경로 지정 엔진과는 달리, 성능의 감소 없이 융통성 있는 경로 지정과 스위칭 기능을 수행할 수 있는 조견표(look-up table) 경로 지정 엔진의 구현에 대하여 기술한다. 제안된 경로 지정 엔진은 조견표의 내용을 바꿈으로써 웜홀(wormhole), 가상 컷스루우(virtual cut-through) 및 패킷 스위칭(packet switching) 등은 물론, 다양한 경로 지정 알고리즘의 혼성(hybride)스위칭을 구현할 수 있다. 경로 지정 엔진의 조견표는 파이프라인 구조로 되어 있어, 하나의 플릿(flit) 정도의 저 지연을 가지므로, 단일 경로 지정 및 스위칭 정책을 하드와이어(hardwired)로 구현한 경우 보다 큰 성능의 감소 없이 다중의 경로 지정 동작을 중첩할 수 있다. 제안된 4개의 파이프 라인단은 해저드(hazard)를 일으키지 않으므로, 고 비용의 포워딩(forwarding) 회로가 필요 없다. 경로 지정 엔진은 시간공유의 컷스루우 버스나 크로스바(crossbar) 스위치를 갖는 단일 경로로 되어 있는 4개의 물리적 경로를수용할 수 있다. 제안된 경로 지정 엔진은 Xilinx 4000XL 시리즈 FPGA를 사용하여 구현되었다.

  • PDF

PWM 인버터와 PWM 정류기에서 공간벡터변조 (Space Vector Modulation in PWM Inverters and PWM Rectifiers)

  • 권봉환;김한태
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.742-752
    • /
    • 1992
  • In this paper, a space vector concept is generalized for PWM(pulse-width modulated) inverters and PWM rectifiers with current link and voltage link respectively. Through representing three-phase variables as a space vector, we propose space vector modulations for PWM voltage and current source inverters, and PWM rectifiers with current link and voltage link. For these types, switching states of the switches are systematically analyzed from tables. It is shown in three-phase PWM rectifiers that power factor of the line current and output dc voltage can be controlled arbitrarily. The PWM rectifier with current link is also given as an example system.

  • PDF

Direct Torque Control Strategy (DTC) Based on Fuzzy Logic Controller for a Permanent Magnet Synchronous Machine Drive

  • Tlemcani, A.;Bouchhida, O.;Benmansour, K.;Boudana, D.;Boucherit, M.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.66-78
    • /
    • 2009
  • This paper introduces the design of a fuzzy logic controller in conjunction with direct torque control strategy for a Permanent Magnet synchronous machine. A stator flux angle mapping technique is proposed to reduce significantly the size of the rule base to a great extent so that the fuzzy reasoning speed increases. Also, a fuzzy resistance estimator is developed to estimate the change in the stator resistance. The change in the steady state value of stator current for a constant torque and flux reference is used to change the value of stator resistance used by the controller to match the machine resistance.

Torque Ripple Minimization in Direct Torque Control of Brushless DC Motor

  • Li, Zhenguo;Zhang, Songfa;Zhou, Shenghai;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1569-1576
    • /
    • 2014
  • This paper mainly proposes a direct torque control strategy to minimize torque ripple in brushless DC (BLDC) motor. BLDC motor has large current and torque ripple when one voltage vector applied in one cycle due to its low inductance. Hence, this paper proposed a hysteresis torque control with PWM mode to control the resultant torque. Moreover, when the direct torque control system is operating during the two-phase half-bridge $120^{\circ}$ conduction mode, large torque ripple in commutation area appears every 120 electrical degree. Based on analyzing the root of torque ripple in detail, lookup tables of switching devices states for new half-bridge modulation mode in the positive and negative reference torque put forwarded. Finally, simulations by MATLAB software and experiment results from DSP are presented to verify the feasibility and effectiveness of the proposed strategy operating in four-quadrant operation.