• Title/Summary/Keyword: Switching tables

Search Result 15, Processing Time 0.021 seconds

Comparison of Efficiency for Different Switching Tables in Six-Phase Induction Motor DTC Drive

  • Taheri, Asghar;Rahmati, Abdolreza;Kaboli, Shahriyar
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, different switching tables proposed for the Direct Torque Controlled (DTC) of a six-phase induction machine are simulated and implemented. A six-phase induction motor has 64 space voltage vectors which result in increased complexity in the selecting of inverters switching. The unsuitable selection of a switching table leads to large harmonics especially at low speed and it also reduces drive efficiency. A six-phase induction machine has large zero sequence harmonic currents of the order $6{\kappa}{\pm}1$. These harmonic currents are varied in various techniques. Decreasing this loss is essential in a six-phase induction machine. The main purpose of this paper is to improve the ST-DTC of six-phase induction machines to reduce the voltage and current harmonics and the torque pulsation. Selecting a suitable method for minimizing these harmonics is very important.

Variables Sampling Inspection Procedures and Tables with Severity Adjustment (계량조정형(計量調整型) 샘플링 검사(檢査)에 관(關)한 연구(硏究))

  • Bai, Do-Sun;Hong, Sung-Hoon;Sohn, Mi-Ae
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.16 no.1
    • /
    • pp.1-15
    • /
    • 1990
  • An AQL type variables sampling system with switching rules is proposed. Comparative studies of existing variables sampling standards - MIL-STD-414, ANSI Z1.9, ISO 3951, and BS 6002 - are made, and simulation studies on switching procedures are conducted. Based on comparative and simulation studies, a variables sampling standard for Korean industry is proposed. The master sampling tables of the proposed standard are taken from the variables standard ANSI Z 1. 9 and the switching rules are matched to the attributes standard KS A 3109 to enable us to move between the proposed variables standard and KS A 3109. Composite OC and ASN curves of the proposed standard are calculated for selected combinations of lot sizes and AQL's and they are compared with those of ANSI Z1.9.

  • PDF

Problems of Stator Flux Estimation in DTC of PMSM Drives

  • Kadjoudj, M.;Golea, N.;Benbouzid, M.E.H
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.468-477
    • /
    • 2007
  • The DTC of voltage source inverter-fed PMSMs is based on hysteresis controllers of torque and flux. It has several advantages, namely, elimination of the mandatory rotor position sensor, less computation time, and rapid torque response. In addition, the stator resistance is the only parameter, which should be known, and no reference frame transformation is required. The DTC theory has achieved great success in the control of induction motors. However, for the control of PMSM drives proposed a few years ago, there are many basic theoretical problems that must be clarified. This paper describes an investigation into the effect of the zero voltage space vectors in the DTC system and points out that if using it rationally, not only can the DTC of the PMSM drive be driven successfully, but torque and flux ripples are reduced and overall performance of the system is improved. The implementation of DTC in PMSM drives is described and the switching tables specific for an interior PMSM are derived. The conventional eight voltage-vector switching table, which is namely used in the DTC of induction motors does not seem to regulate the torque and stator flux in a PMSM well when the motor operates at low speed. Modelling and simulation studies have both revealed that a six voltage-vector switching table is more appropriate for PMSM drives at low speed. In addition, the sources of difficulties, namely, the error in the detection of the initial rotor position, the variation of stator resistance, and the offsets in measurements are analysed and discussed.

Performance Analysis of Group Scheduling with Look-Ahead Algorithm for Optical Burst Switching Networks (광 버스트 스위칭 네트워크에서 Look-Ahead 알고리즘을 적용한 그룰 스케줄링의 성능 분석)

  • Shin, Jong-Dug;Jang, Won-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12B
    • /
    • pp.1037-1043
    • /
    • 2006
  • There has been proposed an algorithm to reduce data burst processing delay in group scheduling in core nodes of optical burst switching networks. Since, in this algorithm, look-up tables containing all the void time information in scheduling windows are generated as soon as the primary group scheduling session terminates, it becomes faster to reassign dropped data bursts to proper voids in different data channels by referring to the tables. The group scheduling with this algorithm showed almost the same channel utilization as the one without using the algorithm but performed a little better in both burst loss probability and wavelength conversion rate. On the other hand, per-burst processing time has been reduced dramatically in the load region of higher than 0.8, showing a factor of 2.1 reduction at 0.9.

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

A Study of Signaling Network Architecture in UMTS Networks Using Signaling Gateway (UMTS 망에서의 SG 도입을 통한 신호망 구조 연구)

  • Cho, Jeong-Je;Park, Sang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.187-188
    • /
    • 2006
  • In CDMA based mobile communication network, signaling messages are routed through Signaling Transfer Point(STP) which is responsible for MTP layer 3 switching. As WCDMA based UMTS network is considered as next generation technology allowing global roaming services, all nodes in networks have their own identity number called Global Title(GT). Therefore, it is essential to introduce Signaling Gateway(SG) responsible for SCCP layer switching to solve the problem each node has all GT tables including even all overseas nodes. In this paper, we propose the signaling network architecture in UMTS networks using SG and we show that we can reduce CAPEX and OPEX in each node. To show the validity of the proposed method some simulations are given in which the results can be expected by intuitive observation.

  • PDF

Low-Latency Programmable Look-Up Table Routing Engine for Parallel Computers (병렬 컴퓨터를 위한 저지연 프로그램형 조견표 경로지정 엔진)

  • Chang, Nae-Hyuck
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.6 no.2
    • /
    • pp.244-253
    • /
    • 2000
  • Since no single routing-switching combination performs the best under various different types of applications, a flexible network is required to support a range of polices. This paper introduces an implementation of a look-up table routing engine offering flexible routing and switching polices without performance degradation unlike those based on microprocessors. By deciding contents of look-up tables, the engine can implement wormhole routing, virtual cut-through routing, and packet switching, as well as hybrid switching, under a variety of routing algorithms. Since the routing engine has a piplelined look-up table architecture, the routing delay is as small as one flit, and thus it can overlap multiple routing actions without performance degradation in comparison with hardwired routers dedicated to a specific policy. Because four pipeline stages do not induce a hazard, expensive forwarding logic is not required. The routing engine can accommodate four physical links with a time shared cut-through bus or single link with a cross-bar switch. It is implemented using Xilinx 4000 series FPGA.

  • PDF

Space Vector Modulation in PWM Inverters and PWM Rectifiers (PWM 인버터와 PWM 정류기에서 공간벡터변조)

  • 권봉환;김한태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.7
    • /
    • pp.742-752
    • /
    • 1992
  • In this paper, a space vector concept is generalized for PWM(pulse-width modulated) inverters and PWM rectifiers with current link and voltage link respectively. Through representing three-phase variables as a space vector, we propose space vector modulations for PWM voltage and current source inverters, and PWM rectifiers with current link and voltage link. For these types, switching states of the switches are systematically analyzed from tables. It is shown in three-phase PWM rectifiers that power factor of the line current and output dc voltage can be controlled arbitrarily. The PWM rectifier with current link is also given as an example system.

  • PDF

Direct Torque Control Strategy (DTC) Based on Fuzzy Logic Controller for a Permanent Magnet Synchronous Machine Drive

  • Tlemcani, A.;Bouchhida, O.;Benmansour, K.;Boudana, D.;Boucherit, M.S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.66-78
    • /
    • 2009
  • This paper introduces the design of a fuzzy logic controller in conjunction with direct torque control strategy for a Permanent Magnet synchronous machine. A stator flux angle mapping technique is proposed to reduce significantly the size of the rule base to a great extent so that the fuzzy reasoning speed increases. Also, a fuzzy resistance estimator is developed to estimate the change in the stator resistance. The change in the steady state value of stator current for a constant torque and flux reference is used to change the value of stator resistance used by the controller to match the machine resistance.

Torque Ripple Minimization in Direct Torque Control of Brushless DC Motor

  • Li, Zhenguo;Zhang, Songfa;Zhou, Shenghai;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1569-1576
    • /
    • 2014
  • This paper mainly proposes a direct torque control strategy to minimize torque ripple in brushless DC (BLDC) motor. BLDC motor has large current and torque ripple when one voltage vector applied in one cycle due to its low inductance. Hence, this paper proposed a hysteresis torque control with PWM mode to control the resultant torque. Moreover, when the direct torque control system is operating during the two-phase half-bridge $120^{\circ}$ conduction mode, large torque ripple in commutation area appears every 120 electrical degree. Based on analyzing the root of torque ripple in detail, lookup tables of switching devices states for new half-bridge modulation mode in the positive and negative reference torque put forwarded. Finally, simulations by MATLAB software and experiment results from DSP are presented to verify the feasibility and effectiveness of the proposed strategy operating in four-quadrant operation.