• 제목/요약/키워드: Switching ripple current

검색결과 282건 처리시간 0.029초

역률 개선 컨버터용 고차 능동 필터의 설계 및 분석 (Design and Analysis of High-order Active Input Filter for Power Factor Correction(PFC) Converter)

  • 이동영;조보형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 1996
  • In this paper, active input filter for power factor correction(PFC) circuit employing ripple arrent and voltage cancellation is proposed to reduce filter's size and cost, and to make filter design easy. Switching ripple current and voltage can be sensed through the secondary windings of filter inductor. Single stage passive filter can achieve high order filter characteristics by using active ripple current and voltage cancellation technique. Conventional high order passive filter and its problems are suggested. Analysis of active filter and design procedure are detailed. Simulation result is presented to verify high order filter characteristics of proposed scheme.

  • PDF

단위 역률을 갖는 3상 강압형 다이오드 정류기에서 고조파 주입에 의한 DC 리플전압 저감 기법 (A DC Ripple Voltage Suppression Scheme by Harmonic Injection in Three Phase Buck Diode Rectifiers with Unity Power Factor)

  • 고종진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode rectifiers is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode rectifiers and guarantee zero-current -switching(ZCS) of the switch over the wide load range The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. IN addition control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations.

  • PDF

AC 서보 모우터의 일정 토크 실현을 위한 제어기 설계 (A Design of Controller on the AC Servo Motor for Constant Torque Implementation)

  • 양남열;이재희;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1047-1050
    • /
    • 1993
  • Recently, AC servo motor has expanded its application areas the to the development of the power semi-conductor and control technology. But it has large torque ripple for its nonlinear characteristics and phase commutaion. In this paper, we proposed the switching angle overlapping method, and current control using tracking method in order to generate the constant torque of AC servo motor that has the trapezoidal back e.m.f. It is compared the these types of control method with the characteristics through simulation. We show that these methods lead the torque ripple to reduce and makes the position and speed characterlistics improved effectively. Also we prove that current control using tracking method is the best way to reduce torque ripple among the these types of control method.

  • PDF

넓은 범위 입력전압에 소프트 스위칭이 가능한 양방향 인터리브드 DC-DC 컨버터 (Bidirectional Soft Switching Three-Phase Interleaved DC-DC Converter for a Wide Input Voltage Range)

  • 최우진;이교범;정규범
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.313-320
    • /
    • 2015
  • This study deals with a bidirectional interleaved soft switching DC-DC converter for a wide range of input voltages. The proposed converter operates in complementary switching with the purpose of inductor size reduction and zero-voltage switching (ZVS) operation. The current ripple related to complementary switching is minimized by three-phase interleaved operation. The main characteristics of the proposed topology are its soft-switching method of operation and its simple structure. The soft-switching operation and the system efficiency of the proposed converter are verified by experimental results.

A Simple Current Ripple Reduction Method for B4 Inverters

  • Lee, Dong-Myung;Park, Jae-Bum;Toliyat, Hamid A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1062-1069
    • /
    • 2013
  • This paper proposes a simple current compensation method to improve the control performance of B4 inverters. Four-switch inverters so called B4 inverters employ only four switches. They have a split dc-link and one phase of three-phase motors is connected to the center-tap of split dc-link capacitors in B4 inverters. The voltage ripples in the center tap of the dc-link generate unbalanced three-phase voltages causing current ripples. To solve this problem, this paper presents a simple compensation method that adjusts switching times considering dc-link voltage ripples. The validity of the proposed method is verified by simulations and experiments carried out with a 1 HP induction machine.

전압 불평형 조건에서 스위칭 소자의 전류용량을 고려한 MMC-HVDC 순환전류 제어기법 (Circulating Current Control in MMC-HVDC Considering Switching Device Current Capacity under Unbalanced Voltage Conditions)

  • 김춘성;정승환;황정구;박성미;박성준
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.55-65
    • /
    • 2016
  • This paper proposed a new control method which is capable of controlling circulating current considering current capacity of switching device. In the unbalanced voltage conditions, active power and reactive power have double line frequency. Thus, in order to provide active power without ripple, it is necessary to inject the negative sequence current components. However, when the negative current components is injected, it increases the total current flowing in the Arm, and in the Sub-module(SM) the current more than rated is impressed, which leads to destroy the system. Also, in impressing the circulating current reference of each arm, conventional control method impressed applicable $i_{dck}/3$ in the case of balanced voltage conditions. In the case of unbalanced conditions, as arm circulating current of three phase show difference due to the power impressed to each arm, reference of each arm is not identical. In this study, in the case of unbalanced voltage, within permitted current, the control method to decrease the ripple of active power is proposed, through circulating current control and current limitations. This control method has the advantage that calculates the maximum active power possible to generate capacity and impressed the current reference for that much. Also, in impressing circulating current reference, a new control method proposes to impress the reference from calculating active power of each phase. The proposed control method is verified through the simulation results, using the PSCAD/EMTDC.

액티브 클램프 포워드 컨버터의 출력 리플 저감에 관한 연구 (A Study on the output ripple reduction of Active-Clamp Forward Converter)

  • 정재엽;김용;배진용;권순도;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.963_964
    • /
    • 2009
  • This paper presents an output ripple reduction of Active-Clamp Forward Converter, which is mainly composed of interleaving two active-clamping forward converters. By interleaving, Output ripple is reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve ZVS during the dead times. The duty cycles are not limited to be equal and within 50%. The complementary switching and the resulted interleaved output inductor currents diminish the current ripple in output capacitors. Accordingly, the smaller output chokes and capacitors lower the converter volume and increase the power density. Detailed analysis of this ouput reduction of Active-Clamp Forward Converter is described.

  • PDF

2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

비대칭 펄스 폭 변조 방식의 배전류 정류기 회로를 적용한 고효율 풀-브릿지 DC-DC 컨버터 (High-Efficiency Full-Bridge DC-DC Converter with Current-Doubler Rectifier with Asymmetric Pulse-Width Modulation)

  • 양민권;최우영
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.280-289
    • /
    • 2015
  • A high-efficiency full-bridge DC-DC converter with a current-doubler rectifier and an asymmetric pulse-width modulation is proposed. Through the asymmetric pulse-width modulation, the proposed converter achieves zero-voltage switching of power switches without the circulating currents. The proposed converter reduces the output current ripple through the current-doubler rectifier. A control strategy is suggested for the proposed converter to charge battery banks. A constant current and constant voltage charging is performed. The proposed converter achieved a higher efficiency compared with the conventional full-bridge DC-DC converter with a phase-shift modulation. The performance of the proposed converter is evaluated by the experimental results for a 1.0 kW prototype circuit.

A Novel High-Performance Strategy for A Sensorless AC Motor Drive

  • Lee, Dong-Hee;Kwon, Young-Ahn
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.81-89
    • /
    • 2002
  • The sensorless AC motor drive is a popular topic of study due to the cost and reliability of speed and position sensors. Most sensorless algorithms are based on the mathematical modeling of motors including electrical variables such as phase current and voltage. Therefore, the accuracy of such variables largely affects the performance of the sensorless AC motor drive. However, the output voltage of the SVPWM-VSI, which is widely used in sensorless AC motor drives, has considerable errors. In particular, the SVPWM-VSI is error-prone in the low speed range because the constant DC link voltage causes poor resolution in a low output voltage command and the output voltage is distorted due to dead time and voltage drop. This paper investigates a novel high-performance strategy for overcoming these problems in a sensorless ac motor drive. In this paper, a variation of the DC link voltage and a direct compensation for dead time and voltage drop are proposed. The variable DC link voltage leads to an improved resolution of the inverter output voltage, especially in the motor's low speed range. The direct compensation for dead time and voltage drop directly calculates the duration of the switching voltage vector without the modification of the reference voltage and needs no additional circuits. In addition, the proposed strategy reduces a current ripple, which deteriorates the accuracy of a monitored current and causes torque ripple and additional loss. Simulation and experimentation have been performed to verify the proposed strategy.