Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors (대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전)

  • 김인동;노의철;전성즙
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.815-820
    • /
    • 2004
  • The parallel operation of voltage source inverters using stator windings of high power three-phase induction motors was proposed in this paper. Most current high power induction motors with more than 4 electric poles have their external terminals installed so that windings of each phase can be approached from the outside. High power induction motors can be driven by parallel-operating several voltage source inverters through these external terminals. This way, in case a certain inverter breaks down, the operation torque will get decreased but the system can maintain its operation with the other inverters, so it can cope more effectively with breakdowns. Moreover, by providing phase difference to the switching movements of each inverter, it can increase equivalent switching frequency, which helps achieve good characteristics such as the reduction in the ripple of output torque, the reduction in the ripple of input current, and the reduction in the size of DC capacitors. Besides, since power is divided into each inverter, it can also decrease the ifluence of EMI occurring in the system. The characteristics of the proposed method were proved through computer simulations in this paper.

Photovoltaic Generation by Parallel Driving of Modified Buck-boost Converter (변형된 승강압 컨버터의 병렬구동에 의한 태양광발전)

  • Lee Hee-Chang;Park Sung-Jun;Park Soo-Sik;Moon Chae-Joo;Lee Man-Hyung;Kim Jong-Dal
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.457-466
    • /
    • 2004
  • In this paper, a modified converter is presented and analyzed to use as a photovoltaic converter. And also a new parallel driving scheme is proposed to increase output power and to reduce the output voltage ripple. The ratio of the output to the input voltage of the modified converter is equal to that of the boost converter. The difference between both converters is the composition of output terminal. Owing to the discrepancy, a working voltage of the output capacitor of the modified converter becomes lower, thus the capacitance value of the capacitor can be smaller than that of the boost converter. The proposed parallel driving is based on the modified converter and a current-mode-control method. It gives a good solution for alleviating the current sharing unbalance problem of conventional parallel operations. It reduces the output voltage ripple by means of increasing the equivalent switching frequency without additional switching losses. The validity of the proposed parallel driving strategy is verified through computer-aided simulations and experimental results.

Vector Controlled Inverter for Elevator Drive (ELEVATOR 구동용 VECTOR 제어 인버터)

  • Shin, H.J.;Jang, S.Y.;Lee, S.J.;Lee, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.627-630
    • /
    • 1991
  • This study is about vector controlled inverter for high quality elevator drive that is to improve the settling accuracy of elevator car and passenger's comfort in commercial buildings. In this study, an instantaneous space vector control type inverter was used to reduce the torque ripple ant to improve the velocity follow-up. This method calculates Instantaneous actual output torque and flux of induction motor by voltage and current, then compares them with a reference values by a speed regulator. The outputs of comparators select a switching mode, for an optimal voltage vector. Also, this study used IGBT (Insulated Gate Bipolar-Transistor), a high speed switching element, to reduce sound noise level, and DSP (Digital Signal Processor) was used to improve the reliability of the control circuit by fully digitalization.

  • PDF

Interleaved Boost-Flyback Converter with Boundary Conduction Mode for Power Factor Correction

  • Lin, Bor-Ren;Chien, Chih-Cheng
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.708-714
    • /
    • 2012
  • This paper presents a new interleaved pulse-width modulation (PWM) boost-flyback converter to achieve power factor correction (PFC) and regulate DC bus voltage. The adopted boost-flyback converter has a high voltage conversion ratio to overcome the limit of conventional boost or buck-boost converter with narrow turn-off period. The proposed converter has wide turn-off period compared with a conventional boost converter. Thus, the higher output voltage can be achieved in the proposed converter. The interleaved PWM can further reduce the input and output ripple currents such that the sizes of inductor and capacitor are reduced. Since boundary conduction mode (BCM) is adopted to achieve power factor correction, power switches are turned on at zero current switching (ZCS) and switching losses are reduced. The circuit configuration, principle operation, system analysis, and design consideration of the proposed converter are presented in detail. Finally, experiments conducted on a laboratory prototype rated at 500W were presented to verify the effectiveness of the converter.

A Study on the Interleaved Active-Clamping Forward Converter (인터리브 방식을 이용한 액티브 클램핑 포워드 컨버터에 관한 연구)

  • Jung, Jae-Yeop;Kim, Yong;Kwon, Soon-Do;Bae, Jin-Yong;Lee, Dong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.156-160
    • /
    • 2009
  • This paper presents the interleaved active-clamping ZVS(Zero Voltage Switching) forward converter, which is mainly composed of two active-clamping forward converters. Only two switches are required, and each one is the auxiliary switch for the other. The circuit complexity and cost are thus reduced. The leakage inductance of the transformer or an additional resonant inductance is employed to achieve ZVS during the dead times. The duty cycles are not limited to be equal and within 50%. The complementary switching and the resulted interleaved output inductor currents diminish the current ripple in output capacitors. Accordingly, the smaller output chokes and capacitors lower the converter volume and increase the power density. Detailed analysis and design of this new interleaved active-clamping forward converter are described.

  • PDF

A Study on LLCL Filter to Reduce Harmonic Current of Grid Connected Power Inverter (계통연계형 인버터의 고조파 전류저감을 위한 LLCL 필터에 관한 연구)

  • An, Byoung-Woong;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • In this paper, the new LLCL filter is proposed for grid connected three-phase PWM inverter for passive damping. LLCL filter inserts a small inductor in the branch of the capacitor of the traditional LCL filter to compose a series resonant circuit to reduce the switching-frequency component on grid current. Using LLCL filter, the switching-frequency current ripple components can be attenuated much better than the LCL filter, leading to a decrease in the total inductance. However, the resonance phenomena caused by zero impedance from the addition of LC branch in LLCL filter can be a big problem. Resonance phenomena of LLCL filter can be a source of grid system instability, so proper damping methods are required. However, it is difficult to apply a passive damping method in the conventional LLCL filter, because the damping resistor increase impedance of the LC branch. Therefore, switching frequency component of grid current can not much attenuated by low Q of LC series resonance effect. In this paper, a new LLCL filter is proposed to overcome the conventional LLCL filter with passive damping. The validity of the proposed method is proven by simulation and experimental result.

Filterless and Sensorless Commutation Method for BLDC Motors

  • Rad, Shahin Mahdiyoun;Azizian, Mohammad Reza
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1086-1098
    • /
    • 2018
  • This study presents a new sensorless commutation method for brushless direct current motors to replace Hall sensor signals with virtual Hall signals. The importance of the proposed method lies in the simultaneous elimination of the phase shifter and the low-pass filters, which makes the method simple and cost-effective. The method removes high ripple switching noises from motor terminals, thereby decreasing motor losses. The proposed method utilizes unfiltered line voltages with notches caused by current commutation. Hence, specific sign signals are defined to compensate for the effects of commutation noise. The proposed method is free from phase delay that originates from low-pass filters. The method directly produces virtual Hall signals, and thus, it can be interfaced with low-cost commercial commutation integrated circuits based on Hall sensors. Simulation and experimental results show the effectiveness and validity of the proposed method.

An Analysis of the discontinous inductor current in the poly-phase buck dc/dc converter (다상 buck형 DC/DC 컨버터의 불연속 인덕터전류 회로의 해석)

  • Choi, J.H.;Ma, K.S.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1022-1024
    • /
    • 1992
  • The multiple poly-phase converters to be overcome the current limits of switching devices have the merits of the lessen weight and ripple. This paper deals with the circuit analysis of the poly-phase buck converters with discontinuous inductor current. The dc and ac models are obtained by the average method of the state equations.

  • PDF

A Neutral-Voltage-Compensated Sensorless Control of Brushless DC Motor

  • Won, Chang-Hee;Song, Joong-Ho;Ick Choy;Lim, Myo-Taeg
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.59-64
    • /
    • 2003
  • This paper presents a new rotor position estimation method for brushless DC motors. The estimation error of the rotor position clearly provokes the phase shift angle misaligned between the phase current and the back-EMF waveforms, which causes torque ripple in brushless DC motor drives. Such an estimation error can be reduced with the help of the proposed neutral-voltage-based estimation method, which is structured as a closed loop observer. A neutral voltage appearing during the normal mode of the inverter operation is found to be an observable and control table measure, which can be used for estimating an exact rotor position. This neutral voltage is obtained from the DC-link current, the switching logic, and the motor speed values. The proposed algorithm, which can be easily implemented by using a single DC-link current and the motor terminal voltage sensors, is verified by simulation and experiment results.

Performance improvement of stepping motor driver using the CPLD (CPLD를 이용한 2상 스테핑 모터 드라이버의 성능개선)

  • O, Tae-Seok;Kim, Il-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.910-915
    • /
    • 2003
  • This paper describes the design of a 2-phase stepping motor driver using CPLD(Complex Programmable Logic Device). The driver IC such as L297 (SGS-Thomson Microelectronics), which is mostly used has some problems in PWM control because of the switching noise of power MOSFETs. It causes current ripple and acoustic noise. To improve theses characteristics, we proposed a new current control method that the output PWM frequency is almost constant using a digital filter. Also we proposed constant current method for 1-2 phase(half step) excitation. The proposed method is implemented with CPLD(Xilinx, XC9572-PC44). Experimental results show the effectiveness of the proposed method.

  • PDF