• Title/Summary/Keyword: Switching filter

Search Result 485, Processing Time 0.02 seconds

Design of High-Power Switched Filter Bank for Harmonic Suppression (하모닉 제거용 고전력 스위치 필터뱅크 설계)

  • Lee, Byeong-Nam;Park, Dong-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.146-153
    • /
    • 2008
  • High-power communication jammer has to include the switched filter bank to eliminate the harmonic signals generated by amplifier. Generally, the switched filter bank consists of in-out switches and several filters. This paper describes the design of high-power switched filter bank, particularly the high-power filter bank operating over 20$\sim$110MHz frequency range. The filters designed have insertion loss less than 0.3dB, VSWR less than 1.25:1, and harmonic suppression more than 35dB. Also, the switched filter bank can endure upto 2kW high-power signal with very low harmonic level within $30{\mu}s$ switching speed.

Design of an LCL-Filter for Three-Parallel Operation of Power Converters in Wind Turbines

  • Jeong, Hae-Gwang;Yoon, Dong-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.437-446
    • /
    • 2013
  • This paper proposes a design scheme for an LCL-filter used for the three-parallel operation of the power converters in high-capacity wind turbines. The designs of the power devices and grid connected filter are difficult due to the high level voltages and currents in huge-capacity wind turbines. To solve these problem, this paper presents three-parallel operation and LCL-filter design techniques optimized by parallel operation. Furthermore, the design of an inverter side inductance of the LCL-filter is discussed in detail considering the switching modulation method. Simulation and experimental results demonstrate the validity of the designed filter and wind turbines.

Study and Design of L-C-L Filter for Single-Phase Grid-Connected PV Inverter (단상 계통연계 태양광 인버터용 L-C-L 필터 설계 및 분석)

  • Cha, Han-Ju;Vu, Trung-Kien
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.228-230
    • /
    • 2009
  • Nowadays, the LCL-filter type becomes an attractive grid interfacing for grid-connected Voltage Source Inverter (VSI). LCL-filter can render the current harmonics attenuation around the switching frequency by using smaller inductance than L-filter. This paper presents a study about the LCL-filter design for single-phase grid-connected inverter in Photovoltaic (PV) system. According to the expected current ripple, the inductances of the filter can be determined. Based on the absorbed reactive power on capacitor, the capacitance can be calculated. Due to the theoretical analysis, a LCL-filter based single phase grid connected inverter control system are simulated. The studied simulation results are given to validate the theoretical analysis.

  • PDF

Adjacent Pixels based Noise Mitigation Filter in Salt & Pepper Noise Environments (Salt & Pepper 잡음 환경에서 인접 픽셀 기반 잡음 완화 필터)

  • Seong, Chi Hyuk;Shin, Soo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.6
    • /
    • pp.65-71
    • /
    • 2017
  • Digital images and videos are subject to various types of noise during storage and transmission. Among these noises, Salt & Pepper noise degrades the compression efficiency of the original data and causing deterioration of performance in edge detection or segmentation used in an image processing method. In order to mitigate this noise, there are many filters such as Median Filter, Weighted Median Filter, Center Weighted Median Filter, Switching Weighted Median Filter and Adaptive Median Filter. However these methods are inferior in performance at high noise density. In this paper we propose a new type of filter for noise mitigation in wireless communication environment where Salt & Pepper noise occurs. The proposed filter detects the location of the damaged pixel by Salt & Pepper noise detection and mitigates the noise by using adjacent pixel values which are not damaged in a certain area. Among the proposed filters, the performance of the filter using the $3{\times}3$ error mask is compared with that of the conventional methods and it is confirmed that when density of noise in the image is 95%, their performances are improved as 13.24 dB compared to MF and 13.09 dB compared to AMF.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

Performance Improvement of a Grid-connected PWM Inverter using a Power Theory (전력 이론을 이용한 계통연계 PWM 인버터 시스템의 성능 개선)

  • Jung, Hea-Gwang;Lee, Kyo-Beum;Kang, Sin-Il;Lee, Hyen-Young;Kwon, Oh-Joeng;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.319-327
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations and experiments.

Comparisons of fatty acid accumulation patterns of two filter feeders, Branchinella kugenumaensis and Daphnia magna in a controlled environment

  • Dongwoo, Yang;Seonah, Jeong;Jihee, Kim;Sangkyu, Park
    • Journal of Ecology and Environment
    • /
    • v.46 no.4
    • /
    • pp.304-315
    • /
    • 2022
  • Background: Filter-feeding zooplankton has limited food resources owing to their habitat. Consequently, it is crucial for them to acquire all essential compounds, such as fatty acids (FAs) and amino acids, from confined diets. To elucidate the trophic transfer of FAs to filter feeders, the primary consumers in freshwater ecosystems, we compared the FA accumulation patterns of two species of filter-feeding zooplankton, Daphnia magna and Branchinella kugenumaensis, in a laboratory experiment. Experimental neonates and nauplii preyed on a single phytoplankton species (Selenastrum capricornutum) for three days after hatching prior to diet switching. Five replicates per feeding group in each species were fed on six different types of mixed phytoplankton diet for 10 days after diet switching. Subsequently, the consumers and diets were harvested and FAs were extracted. Results: Principal component analysis showed that the FA profiles of zooplankton were well-grouped by species and diet. Although diet affects the FA profiles of consumers, they exhibit different FA accumulation patterns. D. magna had a higher 18C-ω3 content and ω3/ω6 ratio than did B. kugenumaensis. In contrast, B. kugenumaensis had higher contents of 18:1ω7 and 20:5ω3 (eicosapentaenoic acid), 22:6ω3 (docosahexaenoic acid), and a higher ratio of ∑18C monounsaturated FAs to ∑18C-ω3 polyunsaturated FAs than did D. magna. Conclusions: This study showed that two primary consumers, D. magna and B. kugenumaensis, fed the same diet had different assimilation patterns of FAs under controlled environments. Specific FA accumulation patterns in filter feeders can provide information on the transfer process of various FAs to high-trophic organisms.

A Variable Dimensional Structure with Probabilistic Data Association Filter for Tracking a Maneuvering Target in Clutter Environment (클러터 환경하에서 기동표적의 추적을 위한 가변차원 확률 데이터 연관 필터)

  • 안병완;최재원;송택렬
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.10
    • /
    • pp.747-754
    • /
    • 2003
  • An enhancement of the probabilistic data association filter is presented for tracking a single maneuvering target in clutter environment. The use of the variable dimensional structure leads the probabilistic data association filter to adjust to real motion of a target. The detection of the maneuver for the model switching is performed by the acceleration estimates taken from a bias estimator of the two stage Kalman filter. The proposed algorithm needs low computational power since it is implemented with a single filtering procedure. A simple Monte Carlo simulation was performed to compare the performance of the proposed algorithm and the IMMPDA filter.

Stability Improvement of Distributed Power Generation Systems with an LCL-Filter Using Gain Scheduling Based on Grid Impedance Estimations

  • Choi, Dae-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.599-605
    • /
    • 2011
  • This paper proposes a gain scheduling method that improves the stability of grid-connected systems employing an LCL-filter. The method adjusts the current controller gain through an estimation of the grid impedance in order to reduce the resonance that occurs when using an LCL-filter to reduce switching harmonics. An LCL-filter typically has a frequency spectrum with a resonance peak. A change of the grid-impedance results in a change to the resonant frequency. Therefore an LCL-filter needs a damping method that is applicable when changing the grid impedance for stable system control. The proposed method instantaneously estimates the grid impedance and observes the resonant frequency at the same time. Consequently, the proposed method adjusts the current controller gain using a gain scheduling method in order to guarantee current controller stability when a change in the resonant frequency occurs. The effectiveness of the proposed method has been verified by simulations and experimental results.

A Study on the Speed Control System of a 3 phase Induction Motor driven by the Full Bridge Inverter with a Low Pass LC Filter (저역통과 LC필터를 가진 전브리지형 인버터로 구동되는 3상유동전동기의 속도제어 시스템에 관한 연구)

  • 박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.538-550
    • /
    • 1998
  • The variable frequency and variable voltage AC source made by a conventional inverter which is composed of power semi-conductors includes much noises in sine wave due to high frequency switching of DC source. In this paper the 3rd low pass LC filter for a variable speed 3 phase induction motor driven by a full bridge inverter is introduced to solve the EMI problem by serious noise current. The utility of a modified 3rd order Butterworth LC filter is confirmed through FFT analysis of sine waves and noiseless ACsource can be obtained by the proposed LC filter. The speed of a 3 phase induction motor driven by a full bridge inverter with a LC filter is satisfactorily controlled by a digital PID controller under the condition of stepwise load and setpoint changes.

  • PDF