• Title/Summary/Keyword: Switching Overvoltage

Search Result 72, Processing Time 0.019 seconds

Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field (준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성)

  • Lee, Bok-Hee;Kim, Dong-Kyu;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.126-132
    • /
    • 2010
  • This paper presents dielectric characteristics of $N_2$ gas under impulse voltages in a quasi-uniform electric field gap. The experiments were carried out at the test gap applied by the 1.2/50[${\mu}s$] lightning impulse voltage, 180/2500[${\mu}s$] switching impulse voltage, 500[ns]/1[MHz] very fast transient overvoltage(VFTO). The gap separation of sphere-to-plane electrodes was 14[mm] and the electric field utilization factor was about 71.2[%]. The gas pressure ranges from 0.2 to 0.6[MPa]. As a result, the electrical breakdowns are occurred by streamer discharge. Breakdown voltages are linearly increased with the gas pressure and the highest breakdown voltage is appeared under the VFTOs having fast rising time. Breakdown voltages under the positive impulse voltages were higher than those under the negative ones, and also the time to breakdown in the positive polarity is longer than that in the negative polarity.

Optimized Capacitor Bank Design for Capacitive Current Test for High Power Laboratory and Analysis with EMTP Simulation (대전력 시험소의 부하시험용 콘덴서 뱅크의 최적 설계 및 EMTP 해석)

  • Ahn, S.H.;Lee, H.C.;Ham, G.H.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1220-1223
    • /
    • 1998
  • High Power Laboratory is the facility for building to simulate the various phenomena generated from electric systems of the real world and to test making and breaking capability, switching capability and durability of circuit breaker, switchgear and other electric utilities, moreover, load equipments which contain capacitor bank is installed for studying the diverse effects originated from the constituent of load through entire systems or receiving end. Such factors, abnormal voltage or current, can be serious in electrical systems, especially, in the case caused by capacitive components such as overvoltage or inrushcurrent, the problems may be more fatal to the systems. In this paper, the optimal design of capacitor bank which will be equipped in High Power Laboratory, which is for simulating as closely as the practical phenomena resulted from the capacitive currents, and the verification aided by computer simulations are presented. For this, analysis of the circuit characteristics according to the standards which can be criteria of the capacitive current tests and the test circuit configuration in accordance with the analysis are proposed in prelude. In the body of the paper the optimal design of capacitor bank has been obtained on the basis of all conditions mentioned above and the test circuit configuration with LGIS test requirements. furthermore, analysis and verification for the design are derived by EMTP. finally, evaluation for the capacitor bank design and further study plan are concluded.

  • PDF