• 제목/요약/키워드: Switching Overvoltage

검색결과 72건 처리시간 0.027초

인버터의 스위칭 서지전압 측정 (A Measurement of Switching Surge Voltage Using Inverter devices)

  • 김종겸;정종호;이은웅
    • 전기학회논문지P
    • /
    • 제53권1호
    • /
    • pp.14-21
    • /
    • 2004
  • Most adjustable-speed drives (ASDs) designed to operate low voltage induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be reflected at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the stator insulation system of a motor. This paper describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

한전 765kV 계통의 개폐과전압 해석 (Switching Overvoltage Analysis of KEPCO 765kV Transimission System)

  • 김정부;심응보;정재기;이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1622-1624
    • /
    • 1994
  • Among the power system overvoltages, switching overvoltages are analysed in this paper, using EMTP(Electro-Magenetic Transient Program ) and TNA(Transient Network Analyzer ). From this analysis, the switching overvoltages are used to determine the BSL(Basic Switching Withstand Level) and the clearance of the transmission tower. Up to now the switching overvoltages were analysed by EMTP, but in order to determine the more exact value of BSL, not only digital but also analog method is required.

  • PDF

EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석 (Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP)

  • 권영목;김재철
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.82-93
    • /
    • 2006
  • 본 논문에서는 인버터 구동 고압유도전동기 운전시 스위칭 서지로 인하여 고압유도 전동기 단자에서 발생하는 과도과전압을 저감하기 위한 필터로 인버터 출력단자에서 dv/dt를 저감하는 LCR 필터와 전동기 입력단자에서 케이블과 유도전동기 특성임피던스를 매칭시키는 RC필터에 대한 과도과전압 저감특성을 분석하였다. 이 필터를 고압에 대용량 유도전동기에 적합하도록 EMTP(ElectroMagnetic Transients Program)를 이용하여 모델링 및 케이블 영향에 의한 필터의 과도과전압 저감효과를 전압파형과 고조파 스펙트럼으로 비교분석하고, 이를 토대로 고압 대용량 유도전동기에 사용될 필터를 제시하였다. 인버터 스위칭 서지에 의한 과도과전압은 유도전동기 고정자 권선에 심각한 전압 스트레스를 발생시켜 절연파괴를 일으키는 주요원인이 된다. 이러한 과도과전압을 저감위한 필터설계는 고압유도전동기 시스템에서 필수적인 요소임을 보였다. 또한 제시된 필터는 과도과전압을 효과적으로 저감시키는 것을 EMTP 시뮬레이션을 통하여 입증하였다.

이선현상을 포함한 고속철도차량의 전도성 잡음 해석 (Analysis on Conductive Noise of High-Speed Train Including Pantograph Detachment)

  • 이성근;조영만;고광철
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.87-92
    • /
    • 2013
  • In high-speed train, the EMI is generated by pantograph detachment and switching device of motor-block. Especially, the conductive noise flows through rail as return feeder influences unintended results to sub-station, transformer, etc. These phenomena were investigated by PSIM circuit analysis tool and each part of railway system is modeled by circuit elements and switching devices. Consequently, the distorted wave in return feeder current occurs by the high speed switching frequency, and the overvoltage is applied by the pantograph detachment. Also the distortion of return current is high in starting point and it decreases from the proximity of a starting point ro the end of terminal.

배전계통에서 UPFC를 이용한 순시전압상승 보상 (Voltage Swell Compensation using an UPFC in Distribution System)

  • 장원혁;이상봉;이명희;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.488-489
    • /
    • 2008
  • Based on the fact that renewable energies such as photovoltaic, wind power, etc. are increasingly used in distribution systems recently which affects overvoltage, this paper implements an unified power flow controller(UPFC) to compensate voltage swell. The implemented scheme employs an ac chopper and a low-pass filter along with a series transformer. The ac chopper converts the amplitude of the voltage down to the nominal value. The low pass filter makes the rough waveform of the output voltage of the ac chopper due to switching smoothly by eliminating harmonics. To verify the effectiveness of the implemented UPFC, the results by Electro-Magnetic Transients Program(EMTP) are presented for various overvoltage cases.

  • PDF

345kV/154kV 계통 과전압 해석과 공기절연간격 산정 (Overvoltage Analysis and Air Clearance Design of 345kV/154kV Transmission Tower)

  • 심응보;우정욱;곽주식;윤상훈;김경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2001
  • This paper described the switching overvoltage analysis on the 345kV and 154kV transmission system by EMTP(Electromagnetic transient Program) for the enactment of current insulation design standards of KEPCO. The air clearance design of current transmission tower was reviewed and revised by the calculated result, considering swing angle for the each type of insulator string by the wind velocity.

  • PDF

중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구 (Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System)

  • 심해섭
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.

부하투입이 고조파 공진에 미치는 영향에 대한 고찰 (A Study on the Harmonic Resonance during Restoration of Primary Restorative Transmission System)

  • 이흥재;이경섭;박성민;유원근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.249-251
    • /
    • 2004
  • Harmonic resonant overvoltage during restoration of primary restorative transmission system originates in switching operations and nonlinear characteristics of equipments. Actually it is difficult to predict the occurrence of harmonic overvoltage, since they result from nonlinear characteristics of transformers and other equipments. This paper describes the analysis of domestic primary restorative transmission system using PSCAD/EMTDC. The harmonic resonance is verified and showed the relation with equipments which have nonlinear characteristics such as generator and transformer in this paper. And the solution to prevent harmonic resonance is proposed too. As a result, the PSCAD/EMTDC simulation showed slightly conflictive results that had been presented by IEEE Power System Restoration Working Group report.

  • PDF

차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터 (A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range)

  • 송인호;유상봉;서범석;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

345kV급 가공송전선로와 GIL이 연계된 혼합송전계통에서 개폐과전압 해석 및 검토 (Switching Surge Analysis and Evaluation in Combined Transmission System with 345kV GIL)

  • 장화윤;이종범;김용갑;장태인
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1811-1816
    • /
    • 2011
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with GIL. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as charging rate, inserting resistance, arrester, length ratio of power cable section, grounding resistance, etc. Analysis is performed by EMTP/ATP.