• 제목/요약/키워드: Switching Operation

검색결과 1,459건 처리시간 0.024초

소프트 스위칭 방식을 갖는 2㎾ PFC 컨버터의 분석 설계 및 실험 비교 (Analysis, Design and Experimental Comparison of 2㎾ Power Factor Corrector Converters With Soft-Switching Methods)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.537-544
    • /
    • 2002
  • This paper describes a comparative analysis of soft switching boost converters through design, production and experiment. Soft switching boost converters are designed to satisfy the condition of input voltage 170-265Vac, output voltage 400Vdc, output current 5A, output power 20W-2000W and unit power factor. In addition, parameter values are designed so that system operation can be compared under this is similar conditions. The efficiency of the combined inductor soft switching boost converter was 97.63% with 1011 load better than that of other boost converter types. The combined inductor soft switching converter has simple circuit construction and low switching loss. EMI resulted by the switching noise, and harmonic distortion.

A new lossless snubber for DC-DC converters with energy transfer capability

  • Esfahani, Shabnam Nasr;Delshad, Majid;Tavakoli, Mohhamad Bagher
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.385-391
    • /
    • 2020
  • In this paper, a new passive lossless snubber circuit with energy transfer capability is proposed. The proposed lossless snubber circuit provides Zero-Current Switching (ZCS) condition for turn-on instants and Zero-Voltage Switching (ZVS) condition for turn-off instants. In addition, its diodes operate under soft switching condition. Therefore, no significant switching losses occur in the converter. Since the energy of the snubber circuit is transferred to the output, there are no significant conduction losses. The proposed snubber circuit can be applied on isolated and non-isolated converters. To verify the operation of the snubber circuit, a boost converter using the proposed snubber is implemented at 70W. Also, the measured conducted Efficiency Electromagnetic Interference (EMI) of the proposed boost converter and conventional ones are presented which show the effects of proposed snubber on EMI reduction. The experimental results confirm the presented theoretical analysis.

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

다분할 디밍구조를 갖는 LED BLU 구동회로에 관한 연구 (Study on the LED BLU Driving Circuit with a Local-dimming Structure)

  • 박유철;김희준;채균;백주원
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.292-300
    • /
    • 2009
  • This paper presents an LED BLU driving circuit with a local-dimming structure. The efficiency of the proposed LED driver has been improved by parallel driving 8 serial-connected LED arrays. It employed the soft-switching boost converter topology to reduce the switching power loss of the hard switching boost converter. Soft- and hard-switching converters have the same structure except that the free-wheeling diode in the hard-switching converter is replaced with the n-channel MOSFET in the soft-switching one. The proposed boost converter was compared with the hard switching converter. The soft-switching converter reveals superior ripple and efficiency. A smaller inductance can be used for the soft-switching converter contrasting to the hard-switching one. We also studied on an over-voltage protection circuit of the output of the driver at the no load condition. The protection circuit was applied to the proposed driver, and its operation was confirmed by experiment. Using a local-dimming technique, power consumption of LCD BLUs can be reduced as low as possible according to the brightness of its image.

절연구간 자동절체 통과 현상 규명용 모의시뮬레이터 제작 (Simulator of Automatic Power Switching System)

  • 한문섭;신효범;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.918-923
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper introduces a simulator that assesses efficiency of automatic power switching systems in neutral sections. The is composed of a power supply system, electric railway vehicles, thyristor switches, and traction motors.

  • PDF

Boost-Half Bridge Single Power Stage Configured PWM DC-DC Converter for Residential PEFC Stack Interface.

  • Khairy, Fathy;Choi, Kwang-Ju;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-134
    • /
    • 2006
  • This paper presents the design and implementation of 1 kW prototype DC-DC power converter with bridge voltage-doubler suitable for small scale PEM fuel cell system and its associated control scheme. The operation principle of this converter is described using some operating waveforms and the switching mode equivalent circuits based on simulation results and a detailed circuit operation analysis and soft-switching conditions.

  • PDF

KOMPSAT-2 Fault and Recovery Management

  • Baek, Myung-Jin;Lee, Na-Young;Keum, Jung-Hoon
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권2호
    • /
    • pp.31-39
    • /
    • 2002
  • In this paper, KOMPSAT-2 on-board fault and ground recovery management design is addressesed in terms of hardware and software components which provide failure detection and spacecraft safing for anomalies which threaten spacecraft survival. It also includes ground real time up-commanding operation to recover the system safely. KOMPSAT-2 spacecraft fault and recovery management is designed such that the subsequent system configuration due to system initialization is initiated and controlled by processors. This paper will show that KOMPSAT-2 has a new design feature of CPU SEU mitigation for the possible upsets in the processor CPUs as a part of on-board fault management design. Recovery management of processor switching has two different ways: gang switching and individual switching. This paper will show that the difficulties of using multiple-processor system can be managed by proper design implementation and flight operation.

PWM 콘버어터를 이용한 순시무효전력 보상장치의 동작해석 (A Study on the Operation Characteristics of a Reactive Power Copensator using PWM Converter)

  • 권기현;권순재;김철우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.310-312
    • /
    • 1989
  • From the viewpoint of an effective energy use, many method for reactive power compensation has been developed. Among of the reactive power compensation, this paper describes the relation of operation interpretation, filter, hysteresis width and switching time of current controlled PWM converter which has excellent reactive power compensation. This current controlled PWM convertor is excellent the view of reactive power compensation by current control method using hysteresis comparator method, but is required element of high response characteristics. Therefore this paper offers the series of data for system considering switching characteristics of switching element.

  • PDF

인터리브드된 전류 주입형 고승압 DC-DC 컨버터 (Interleaved Current-fed High Step-up DC-DC Converter)

  • 이준호
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.586-591
    • /
    • 2020
  • 본 논문에서는 인터리브된 전류 주입형 고승압 DC-DC 컨버터가 제안된다. 높은 전압 이득 외에도 인터리빙 방식을 채택하여 낮은 리플 입력 전류가 달성된다. 또한 제안 된 컨버터의 소프트 스위칭 특성은 전력 스위치의 스위칭 손실을 줄이고 변환 효율을 높인다. 변압기의 누설 인덕턴스를 활용하여 다이오드의 전류 변화율을 제어함으로써 출력 정류기의 역 회복 문제도 완화된다. 200W 프로토 타입에서 얻은 실험 결과에 대해 설명한다.

유도 가열용 SEPP 인버터의 특성 해석 (Analysis of SEPP type Inverter for Induction Heating)

  • 문창수;백승면;심광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1911-1913
    • /
    • 1998
  • This paper has described about a SEPP Inverter for induction heating load. It is analyzed theoretically about the Inverter operation for induction heating. According to the parameters of induction heating load, it is proposed a method of circuit analysis and operation characteristics of the Inverter. In addition, the soft switching technology known as ZVS(Zero Voltage Switching) is used to reduce turn on and off loss at switching. The Proposed inverter shows it can be practically used as power source system for high frequency induction heating appliancs.

  • PDF