Frequency Spectrum Analysis of Corona Discharge as Electrode Structures (전극 구조에 따른 코로나 방전의 주파수 스펙트럼 분석)

  • Jung, Kwang-Seok;Kim, Sun-Jae;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.118-118
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves which is generated by corona discharges as a basic study to develop a on-line diagnostic technique for power facilities installed in a closed-switchboard. Five types of electrode system were arranged to simulate corona discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. These results showed that the frequency spectrum of corona discharges exists widely in ranges from 30 to 1,000 [MHz].

  • PDF

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard (전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kang, D.S.;Kim, J.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Development of electromagnetic wave detecting equipment for diagnosis of partial discharge in enclosed switchboard (폐쇄 배전반에서의 부분 방전 On-Line 열화 감시 시스템 개발)

  • Jun, K.H.;Kang, C.W.;Kim, J.C.;Kim, K.H.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.318-320
    • /
    • 2000
  • This paper presents the develop-ment of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

A Development of the Digital Switchboard for the High Voltage Customer (고압전자식 배전반 개발)

  • Byun, Young-Bok;Joe, Ki-Youn;Jyung, Je-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.803-805
    • /
    • 1993
  • This paper describes the development of a digital multifunction controller for the protection, measurement and control of the high voltage customer switchboard. The magnitude of the fundamental component is estimated using a simple filter based on cross-correlation with a heptagonal wave. The characteristics of flexible relay functions such as adjustable pickup and time-dial settings, various time-magnitude curve and directional capability including measurement functions are presented. The controller implementation is carried out on two microprocessors for real time operation.

  • PDF

Unification of examination paper switchboard (단일화 스트립지 교환기 개발)

  • Han, hyun-ji;Kim, min-yeong;Lee, gi-young;Lee, sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.138-143
    • /
    • 2012
  • In the study, we were develop unification of examination paper switchboard that reduced the hassle about previously glucose measurement. Examination paper case was produced to magazine for minimize when you use the previously products occurred hand pollution or loss rate. And, Quantity of examination paper can be checked in real time by seeking the convenience of patients. In this study, we selected one model but you can product any examination paper case. Data was construct through surveys to questionnaires and satisfaction. Purchasing was received to high rating 67%. In this study, we were trying minimize inconvenience during self scan for diabetes patient. Further, we were suggest various products that were improve the functionality and practicality through practicality in design.

An Analysis of the Relationship between Elevator Emergency(Entrapment) and Situation Measurement of Sag/Interruptions at the Switchboard

  • Kim, Gi-Hyun;Lim, Young-Bae;Bai, Seok-Myung;Kim, Jae-Chul;Lee, Hee-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-44
    • /
    • 2007
  • This study researched the mutual relationship between elevator emergencies(sudden stops, entrapment) and power quality such as voltage interruptions or sags. To analyze the power quality at the elevator switchboard of an apartment, the on-line power quality(sag, swell, and interruption, etc.) were measured and error messages(under voltage error, etc.) in the elevator control room were researched. Also the performance and susceptibility for stops were evaluated and stated through the testing of three pieces of simulated test equipment with an EN12016(2004) standard setting and the magnitude and duration data of the measured sag or interruption. This paper will use these data in the analysis of the mutual relationship between power quality and elevator emergencies.

Mention Detection and Coreference Resolution Pipeline Model for Dialogue Data (대화 데이터를 위한 멘션 탐지 및 상호참조해결 파이프라인 모델)

  • Kim, Damrin;Kim, Hongjin;Park, Seongsik;Kim, Harksoo
    • Annual Conference on Human and Language Technology
    • /
    • 2021.10a
    • /
    • pp.264-269
    • /
    • 2021
  • 상호참조해결은 주어진 문서에서 상호참조해결의 대상이 될 수 있는 멘션을 추출하고, 같은 개체를 의미하는 멘션 쌍 또는 집합을 찾는 자연어처리 작업이다. 하나의 멘션 내에 멘션이 될 수 있는 다른 단어를 포함하는 중첩 멘션은 순차적 레이블링으로 해결할 수 없는 문제가 있다. 본 논문에서는 이러한 문제를 해결하기 위해 멘션의 시작 단어의 위치를 여는 괄호('('), 마지막 위치를 닫는 괄호(')')로 태깅하고 이 괄호들을 예측하는 멘션 탐지 모델과 멘션 탐지 모델에서 예측된 멘션을 바탕으로 포인터 네트워크를 이용하여 같은 개체를 나타내는 멘션을 군집화하는 상호참조해결 모델을 제안한다. 실험 결과, 4개의 영어 대화 데이터셋에서 멘션 탐지 모델은 F1-score (Light) 94.17%, (AMI) 90.86%, (Persuasion) 92.93%, (Switchboard) 91.04%의 성능을 보이고, 상호참조해결 모델에서는 CoNLL F1 (Light) 69.1%, (AMI) 57.6%, (Persuasion) 71.0%, (Switchboard) 65.7%의 성능을 보인다.

  • PDF

A System Effectiveness Simulation Model for Underwater Battery Propulsion Systems (수중 배터리 추진시스템 효과도 시뮬레이션에 관한 연구)

  • Ko, Yong-Seog;Yun, Won-Young
    • IE interfaces
    • /
    • v.11 no.2
    • /
    • pp.25-37
    • /
    • 1998
  • In this paper, a simulation model is proposed to evaluate the system effectiveness of underwater battery propulsion systems which consist of motors, main switchboard, generators and batteries. The various operating environments such as emergency situations, equipment's failure and repair, and system performance degradation due to equipment's failures affect the system effectiveness and the environment elements are considered as the input parameters in the simulation model. Some simulation results with estimated data are studied.

  • PDF

High-Accuracy Current Sensing Technique Based on Magnetic Sensors for Three-Phase Switchboards (삼상 배전반에서 자기센서 기반의 고정밀 전류 측정 기법)

  • Lee, Sungho;Kim, Taemin;Kim, Namsu;Ahn, Youngho;Lee, Sungchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.993-998
    • /
    • 2017
  • In this paper, a high-accuracy current sensing technique for three-phase current paths in an electrical switchboard is proposed. Conventional open-style current sensors using magnetic sensors show inaccurate sensing performance with more than 10% error due to undesired magnetic field interference from neighboring paths. To increase accuracy, large and expensive current transformers with large permeabilities have been used, which increased the cost and size. The proposed technique can improve the measured magnetic field by the calculation of magnetic interference effect from neighboring current paths. The relationship between neighboring magnetic fields and the desired magnetic field is theoretically analyzed in a general case. The proposed technique is verified using magnetic field simulations in a three-phase busbar environment.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.