• 제목/요약/키워드: Swipe Sample

검색결과 5건 처리시간 0.022초

Uranium Isotopic Ratio Analysis of U-Bearing Particulates By SIMS in CIAE

  • Yonggang, Zhao
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 Proceedings of the 4th Korea-China Joint Workshop on Nuclear Waste Management
    • /
    • pp.257-259
    • /
    • 2004
  • In this paper measurement method of uranium isotope ratio of uranium-bearing particles in swipe samples was introduced; Swipe sample screening program was proposed on the basis of studying various destructive assay and non-destructive assays. Scanning electron microscope(SEM) equipped with an energy dispersive X-ray fluorescence(XRF) system was applied to locate the deposited uranium-containing particles on the graphite support, particle's composition and size can be identified. Some isotope ratio results were compared with those of other bulk analytical methods; By measuring the same prepared sample, we got the U-particle isotopic ratio data similar to those from IAEA NWAL, indicating that our operation parameters and experimental conditions are viable and can be used for measurement of U-particle isotopic ratio from swipe samples.

  • PDF

PRELIMINARY STUDY ON THE ALPHA TRACK ANALYSIS OF SPHERICAL URANIUM METAL PARTICLES

  • Pyo Hyung-Yeol;Kim Jong-Yun;Lee Myung-Ho;Park Yong-Jun;Jee Kwang-Yong;Kim Won-Ho
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.353-358
    • /
    • 2006
  • Alpha track analysis for the determination of the trace amount of alpha emitting nuclides in a very small particle was performed as an efficient and powerful technique during safeguard inspection. Metal particles with well-defined spherical shape, size and isotopic compositions as a reference material were used to correlate the number of tracks or track diameter with an isotopic composition eventually to identify the uranium enrichment in the environmental swipe samples. Slopes in the number of tracks versus the exposure time curve provide a simple insight into the uranium enrichment of an unknown particle. Low enriched uranium metal particles result in slopes still steeper than the depleted or natural uranium metal particles. In addition, a linear relationship between track diameter and particle size Is thought to be a useful first stage analytical tool as an efficient and convenient inspection guide. The significance of the simple linear model was also judged using the usual statistical tests.

극저준위 백그라운드 감마선 측정시스템의 성능시험 (Performance Test of the Ultralow Background Gamma-Ray Measurement System)

  • 나원우;이영길
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.219-226
    • /
    • 1997
  • 환경시료 및 Swipe시료에서 방출되는 감마선을 측정 분석하기 위하여 극저준위 백그라운드 감마선 측정시스템을 설치하였다. 본 측정시스템은 백그라운드를 저감하기 위해 극저방사능 물질로 구성된 수동적 차폐방법, 우주선 영향을 차단하기 위한 역동시 측정법, 그리고 공기중 방사성 핵종인 라돈가스를 시스템 내부에서 제거하는 방법 등을 적용하고 있다. 적용된 백그라운드 저감법에 대한 성능시험 결과, 실험실 조건의 백그라운드 준위가 관심 대상 에너지 영역($50\;keV{\sim}2\;MeV$)에서 $10^{-2}$ order 정도로 저감되었다. 그리고 미신고 핵활동을 탐지하기 위한 관심 대상 핵종의 감마선 에너지 영역에서 평가된 시스템의 최소검출하한(MDA)값은 환경시료 분석에 적합한 것으로 평가되었다. 그러나 저에너지 영역에서는 여전히 우주선에 의한 중성자 영향이 백그라운드 요인으로 작용하고 있는 것으로 분석되었다.

  • PDF

Improvement of Measurement Precisions for Uranium Isotopes at Ultra Trace Levels by Modification of the Sample Introduction System in MC-ICP-MS

  • Park, Ranhee;Lim, Sang Ho;Han, Sun-Ho;Lee, Min Young;Park, Jinkyu;Lee, Chi-Gyu;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • 제7권2호
    • /
    • pp.50-54
    • /
    • 2016
  • Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is currently used in our laboratory for isotopic and quantitative analyses of nuclear materials at ultra-trace levels in environmental swipe samples, which is a very useful for monitoring undeclared nuclear activities. In this study, to improve measurement precisions of uranium isotopes at ultratrace levels, we adopted a desolvating nebulizer system (Aridus-II, CETAC., USA), which can improve signal sensitivity and reduce formation of uranium hydride. A peristaltic pump was combined with Aridus-II in the sample introduction system of MC-ICP-MS to reduce long-term signal fluctuations by maintaining a constant flow rate of the sample solution. The signal sensitivity in the presence of Aridus-II was improved more than 10-fold and the formation ratio of UH/U decreased by 16- to 17- fold compared to a normal spray chamber. Long-term signal fluctuations were significantly reduced by using the peristaltic pump. Detailed optimizations and evaluations with uranium standards are also discussed in this paper.

Preparation and Consideration of Sample Collection in Undeclared Areas for Denuclearization Verification

  • Kim, Dong Yeong;Kim, Giyoon;Lee, Jun;Lim, Kyung Taek;Chung, Heejun;Seo, Jihye;Kim, Myungsoo
    • 방사성폐기물학회지
    • /
    • 제19권4호
    • /
    • pp.479-489
    • /
    • 2021
  • The Republic of Korea is expected to participate in the denuclearization verification activities by the International Atomic Energy Agency (IAEA) in case any neighboring countries declared denuclearization. In this study, samples for the verification of nuclear activities in undeclared areas were selected for the denuclearization of neighboring countries, and the appropriateness of the procedures was considered. If a country with nuclear weapons declares denuclearization, it must be accompanied by the IAEA's verification regarding nuclear materials and weapons in the declared and undeclared areas. The analysis of the process samples or on-site environmental samples and the verification of undeclared nuclear facilities and materials aid in uncovering any evidence of concealment of nuclear activity in undeclared areas. Therefore, a methodology was established for effective sampling and analysis in accordance with proper procedures. Preparations for sampling in undeclared areas were undertaken for various potential scenarios, such as, the establishment of zones according to radiation dose, methods of supplying electricity, wireless communication networks, targets of sampling according to characteristics of nuclides, manned sampling method, and unmanned sampling method. Through this, procedures were established for pre- and post-site settings in preparation for hazards and limiting factors at nuclear inspection sites.