• Title/Summary/Keyword: Suture Materials

Search Result 190, Processing Time 0.029 seconds

Comparison of Clinical Outcome of Excision versus Osteosynthesis in Type II Accessory Navicular (족부 제2형 부주상골에서 절제술과 골유합술 간의 임상적 결과 비교)

  • Lee, Jong-Seok;Youn, Hyun-Kook;Choi, Woo-Jin;Lee, Jin-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • Purpose: The purpose of this study is to compare the clinical outcome of excision versus osteosynthesis of type II accessory navicular performed by a single surgeon. Materials and Methods: Cases of 14 feet treated with excision and 13 feet by osteosynthesis for type II accessory navicular of 25 patients from 2002 to 2009 were included in this study. Radiological measurements and American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scale was evaluated. Results: AOFAS midfoot scale of both excision and osteosynthesis groups at last follow-up showed improvement from pre-operation. However, there was no statistical difference in AOFAS midfoot scale and subjective satisfaction between the two groups at last follow-up. In detail of AOFAS midfoot scale, pain and footwear requirements showed statistically favorable results for the excision group, while activity limitation and support showed statistically favorable results for the osteosynthesis group. Subjective recovery time returning to daily activities and starting rehabilitation exercise were 14.6 weeks in the excision group and 13.7 weeks in the osteosynthesis group (p=0.025, Mann-Whitney). Suture anchor loosening was observed in one case in the excision group and non-union in two cases in the osteosynthesis group. Conclusion: Both excision and osteosynthesis are favorable surgical methods, but each method has advantages and possible complications such as suture anchor loosening or non-union. Surgeon's preference, patient's chief complaint, specific needs of patient after the operation and consideration of the size of accessory navicular can be a criteria to consider when selecting a surgical method.

Effect of Chitosan on Expression of Osteogenic Genes during the Healing of Rat Extraction Socket

  • Youn, Gap-Hee;Jung, Seunggon;Lee, Tae-Hoon;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of Korean Dental Science
    • /
    • v.7 no.2
    • /
    • pp.58-65
    • /
    • 2014
  • Purpose: This study was performed to evaluate the effect of chitosan combined with absorbable gelatin compressed sponge on the expression of osteoblastic differentiation marker genes during the healing of rat extraction socket. Materials and Methods: Twenty-four male Wistar rats were used. In control group, the extraction socket was closed with suture. In chitosan group, the socket was filled with chitosan combined with Gelfoam (Pharmacia & Upjohn Co.) and closed with suture. In each group, the animals were sacrificed at 3 days, 1 week, 2 weeks, and 4 weeks postoperatively. The expression of osteoblastic differentiation marker genes, including BSP, OCN, Runx2, and Col1 were quantified by real-time polymerase chain reaction. Result: Compared to control group, the mRNA level of BSP in chitosan group increased significantly at 2 weeks after extraction and the level of OCN decreased significantly at 3 days and 4 weeks after extraction (P<0.05). The mRNA levels of OCN, Runx2, and Col1 in chitosan group increased slightly at 2 weeks after extraction, but there was no statistical difference between groups. Conclusion: The results indicate that chitosan has some effects on the expression of osteogenic genes during the healing of extraction sockets.

Radiographic features of cleidocranial dysplasia on panoramic radiographs

  • Symkhampha, Khanthaly;Ahn, Geum Sun;Huh, Kyung-Hoe;Heo, Min-Suk;Lee, Sam-Sun;Kim, Jo-Eun
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.271-278
    • /
    • 2021
  • Purpose: This study aimed to investigate the panoramic imaging features of cleidocranial dysplasia (CCD) with a relatively large sample. Materials and Methods: The panoramic radiographs of 40 CCD patients who visited Seoul National University Dental Hospital between 2004 and 2018 were analyzed. Imaging features were recorded based on the consensus of 2 radiologists according to the following criteria: the number of supernumerary teeth and impacted teeth; the shape of the ascending ramus, condyle, coronoid process, sigmoid notch, antegonial notch, and hard palate; the mandibular midline suture; and the gonial angle. Results: The mean number of supernumerary teeth and impacted teeth were 6.1 and 8.3, respectively, and the supernumerary teeth and impacted teeth were concentrated in the anterior and premolar regions. Ramus parallelism was dominant (32 patients, 80.0%) and 5 patients (12.5%) showed a mandibular midline suture. The majority of mandibular condyles showed a rounded shape (61.2%), and most coronoid processes were triangular (43.8%) or round (37.5%). The mean gonial angle measured on panoramic radiographs was 122.6°. Conclusion: Panoramic radiographs were valuable for identifying the features of CCD and confirming the diagnosis. The presence of numerous supernumerary teeth and impacted teeth, especially in the anterior and premolar regions, and the characteristic shapes of the ramus, condyle, and coronoid process on panoramic radiographs may help to diagnose CCD.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Gutter Splint for Ingrown Toe Nail in Young Patients (어린 환자에서 내향성 조갑증에 대한 조갑홈통 부목을 이용한 치료)

  • Shin, Yong-Woon;Bae, Su-Young;Ahn, Sang Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.111-115
    • /
    • 2018
  • Purpose: Ingrown toenails are a common disease in the adolescent period and the treatments could be more conservative for this early stage of the disease. This study is a case series on the results of a gutter splint for an adolescent ingrown toe nail as a simple, comfortable treatment method. Materials and Methods: From 2011 to 2018, 22 patients (mean age, 12.2 years; range, 8~15 years) with ingrown toenails were treated with a gutter splint. There were 16 boys and 6 girls with 7 patients on both great toes, and additional 4 both corners of a nail, giving a total of 33 splints. Flat, plastic straws and glue or suture were used to protect the nail corners under local anesthesia. The medical records were reviewed retrospectively and phone calls were made to obtain the long-term results. Results: Fifteen splints were fixed with a suture and the other 18 splints were fixed with glue. There were 9 cases of recurrence out of 33 gutter splints, 8 out of 15 sutured splints and 1 out of 18 glued splints (p=0.010). There was no gender (p=0.383) or age (p=0.305) difference in the number of recurrences. Conclusion: For growing people, ingrown nails can be cured easily by conservative treatment for a transiently shortened or broken toenail. The glued gutter splint had a reasonable success rate as a first line treatment.

Arthroscopic Bankart Repair: At Least 5 Years Follow-up (관절경적 Bankart 병변 봉합술: 5년 이상 추시 결과)

  • Heo, Mu-Jung;Kim, Kyung-Taek;Kim, Chul-Hong;Kang, Min-Soo;Kim, Hyeon-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: To evaluate the efficacy of arthroscopic Bankart repair using metal suture anchors for treatment of chronic traumatic anterior instability of shoulder joint. Materials and Methods: 85 patients (80 male and 5 female) were included in this study. The average age was 26 (15~52) years old and the period from the first injury to operation was average 20 (6~38) months. All cases had Bankart lesion and 44 cases had Hill-Sachs lesion. The SLAP lesion was associated in 10 cases and 7 cases had partial rotator cuff tear. The average follow-up period was 89 (68~108) months. Results: Preoperative Rowe score was average 29.3 (25~50) and Rowe score improved to 86.8 (40~100), excellent in 28 cases (32.9%) and good in 46 cases (54.1%) at last follow up period and 70 cases (82.4%) had full range of motion of the shoulder. The arthroscopic revision surgery of the shoulder was performed in 3 cases (3.5%) because of postoperative re-dislocation. Conclusion: We concluded that arthroscopic Bankart repair with metal suture anchors is one of the reliable and effective method for recurrent anterior shoulder dislocation with Bankart lesion.

  • PDF

Study for the Usefulness of Arthroscopic Repair with UU MA SB Stitch for the Full Thickness Rotator Cuff Tear (preliminary report) (회전근개 파열에서 관절경 감시하의 봉합술 - UU MA Suture Bridge를 이용한 봉합의 유효성(예비보고) -)

  • Ko, Sang-Hun;Lee, Seon-Ho;Rhee, Young-Girl;Lee, Chae-Chil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • Purpose: To evaluate the clinical results of arthroscopic repair with Ulsan University - Mason Allen - Suture Bridge (UU MA SB) stitch for the full thickness rotator cuff tear. Materials and Methods: Fifteen patients with full thickness rotator cuff tear underwent arthroscopic repair with UU MA SB stitch between September 2010 and December 2010. Clinical and functional evaluations were made according to Korean shoulder score (KSS), American shoulder and elbow surgeon (ASES), University of California, Los Angeles (UCLA), visual anabgue scale (VAS) and the range of motion. Results: The mean KSS improved from 51.4 preoperatively to 92.0 at final follow-up (p<0.05). The mean UCLA score improved from 15.07 preoperatively to 31.93 postoperatively, the mean VAS of pain during the motion was 7.2 before treatment and 0.93 at final follow-up (p<0.001). At last follow-up, the mean range of motion was improved but they had not shown statistical significance (p>0.05). Conclusion: The arthroscopic repair with UU MA SB stitch may be an effective procedure in the full thickness rotator cuff tear for pain relief and improvement of the range of motion.

  • PDF

Surgical Treatment of Ruptured Achilles Tendon - End-to-end suture & Paratendinous wrapping (아킬레스건 파열의 수술적치료 -단단 봉합술 및 건외막피복술-)

  • Hwang Deuk-Soo;Lee Won-Seok;Kim Kyung-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.2
    • /
    • pp.138-142
    • /
    • 2002
  • Purpose: To evaluate the results and prognosis of operative repair to acute rupture of achilles tend on associated sports injury. Materials and Methods: 21 cases were surgically treated and average follow-up period was 1 year and eight months. The forth decade was most common with $55\%$ and soccer was most common in sports with 5 cases. End-to-end suture of ruptured achilles tendon was performed, and paratendinous structure was wrapped sufficiently. Postoperatively. ankle was plantarflexed for 6 weeks with longleg cast. And then 2 weeks interval, short leg cast with equinous position was conversed to functional position. About 10 weeks after operation, ankle was recovered to right angle. Hooker scale was used to evaluate the results. Results: Compared to normal side, heel-floor distance of ruptures side was decreased 0.7 cm in average, and 0.8 cm was deceased after 20 times weight loaded dorsiflexion. Mid-calf circumference was deceased 0.3 cm, and active dorsiflexion and plantar flexion of ankle was decreased each 3 and 5degree. 16 cases showed ‘excellent’result and 5 cases showed ‘satisfactory’. There was no complication, such as re-rupture or infection at operation site. Conclusion: After end-to-end operative repair to achilles tendon, sufficient wrapping of paratendinous structure is efficient for healing and prevention of postoperative adhesion. And serial dorsiflex-ion cast change is considered to be a successful treatment for preventing residual equinus deformity.

  • PDF

Comparison of the Modified Brostrom Repair Technique with and without Augmentation Using Suture Tape for Chronic Ankle Instability (만성 족관절 불안정성을 가진 환자군에서 변형 브로스트롬 술식과 봉합 테이프를 추가한 술식 간의 결과 비교)

  • Gwak, Heui-Chul;Jung, Soo-Hwan;Kim, Jung-Han;Park, Dae-Hyun;Choo, Hye-Jung;Kim, Dae-Yoo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.1
    • /
    • pp.40-47
    • /
    • 2022
  • Purpose: The modified Broström repair (BR) technique has yielded good outcomes in patients with chronic ankle instability. This study compared clinical and radiological outcomes between two groups of patients who underwent modified BR or lateral ligament augmentation using suture tapes (ST). Materials and Methods: Seventy-seven patients (ST group [n=47], BR group [n=30]; body mass index <26.61 kg/m2; mean age, 30.7±11.0 years [range, 17~39 years]; mean follow-up, 34.0±12.0 months [range, 24~59 months]) were retrospectively reviewed between January 2014 and July 2017. The Foot and Ankle Outcome Score (FAOS), American Orthopedic Foot and Ankle Score (AOFAS), Foot and Ankle Ability Measure (FAAM), visual analogue scale (VAS) score, and Sefton grading system were used for clinical assessment. The talar tilt angle and anterior talar translation were measured using the Telos stress device (Telos GmbH, Marburg, Germany) at 150 N for radiological evaluation. Results: FAOS, AOFAS, FAAM, and VAS scores improved in both groups at final follow-up (ST, 91.1±5.2, 93±2, 88.1±4.5, 1.5±0.7 vs. BR, 91.3±5.4, 93±3, 83.3±4.8, 1.2±0.7, respectively; p=0.854, 0.971, <0.001, 0.04, respectively). According to the FAOS, mean sports activity scores for the ST and BR groups at the final follow-up were 90.3±3.2 and 76.6±4.2, respectively, reflecting superior outcomes in the ST group (p<0.001). Sefton grading revealed satisfactory functional outcomes (ST, 91.5% vs. BR, 90.0%). There was significant improvement in the talar tilt angle and anterior talar translation in both the ST and BR groups (7.6°±1.2°, 10.5±1.8 mm vs. 4.9°±1.1°, 7.9±1.5 mm, respectively; p<0.001). Conclusion: The ST group demonstrated comparable clinical but better improvement in mechanical stability and FAOS sports scores than the BR group.

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF